Product Short Description: DO NOT store your pH electrode in distilled or deionised water as this will cause ions to leach out of the glass membrane and reference electrolyte, causing a slow and sluggish response.
Product Description:

DO NOT store your pH electrode in distilled or deionised water as this will cause ions to leach out of the glass membrane and reference electrolyte, causing a slow and sluggish response.

It is a solution prepared with reagent grade chemicals that that can be used to ensure optimum performance of  Electrode.The life  electrode is not infinite. A number of factors affect the life span of your  electrode. The higher the temperature that the electrode is used at, the more extreme , how often the bulb dries out and needs to be rehydrated, how roughly it is used; all these factors and more shorten the life span of your electrode. An   electrode
that is well maintained and cared for can last up to 2 years, one that is not well maintained will not last as long, and one that is well maintained will not last significantly longe.Electrode Storage Solution helps to keep your  electrodes corrosion free between uses. These solutions are easy-to-use.

 

This is special formulation to minimize microbial growth and osmotic / diffusion effect between the solution and inner reference electrolyte. Manufactured specifically for pH , ORP and other testing elctrodes.

Product Application:

Storage of the pH electrode when not in use :  The electrode bulb needs to be moist at all times. When you are done with the electrode pour, electrode storage solution into the cap that came with the electrode and put the cap over the bulb of the electrode. Keep the cap on until next use. If the electrode is being stored for a long time you may want to check the cap to be sure the storage solution is still in the cap and keeping the bulb moist. 

Rinsing the  electrode between measurements. You should rinse your  electrode between measurements. This can be done with distilled water or rinsing with a sample of the next solution to be measured. Using both distilled water and then a sample of the next solution is also a good way to rinse the  electrode between measurements.

pH electrode fill hole : Some  electrodes have a fill hole for refreshing the electrolyte in the  electrode; other  electrodes do not have a fill hole. If your electrode has a fill hole the fill hole cap should be removed during calibration and use. This allows for the correct amount of reference electrolyte to flow into the sample. Replace the fill hole cap when done with the electrode at the end of the day.

Product Dose:

Immerse probe in Electrode Storage Solution, making sure entire probe stays submerged. After storage, rinse with clean tap water or distilled water before using. Store at room temperature between 20°C – 25°C. Clean the probe with Electrode Cleaning Solutions  before storage if probe has been immersed in several nutrient solutions without cleaning.

Product Note:

DO NOT STORE THE pH ELECTRODE IN DISTILLED WATER. Storing the pH electrode in distilled water will shorten the life of your pH electrode. If you do not have electrode storage solution, temporary use pH 4 buffer solution.

Product Technical Specification:

Physical Properties :

Appearance : Colorless liquid
Odor : Odorless
Density at 20 °C : 1.02 g/cm³
pH : 5-7
Boiling Point : > 100 °C
Flash Point : NA
Solubility : Complete soluble
Remarks:
prod_useful_area:
Product Supply Location:

Electrode Storage Solution manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Electrode Storage Solution at a competitive price from us. We have ready stock of Electrode Storage Solution in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

stock-clearance.png