Images: Alt
Product Short Description: Hydro-testing corrosion protection for Pipeline, Tank contains corrosion inhibitor, oxygen scavenger and biocide
Product Description:

Hydro Testing Corrosion Inhibitor RXSOL 4000 is a multicomponent, multifunctional formulation which prevents corrosion, microbiological growth in single product treatment programme. Inhibitor, corrosion, multicomponent, multifunctional: For prevention of corrosion and microbiological growth in water flood systems during hydrostatic testing and other applications.

Hydro Testing Corrosion Inhibitor RXSOL 4000 is a cocktail of water soluble chemicals designed to protect pipelines from corrosion during hydrostatic testing and mothball operations. Hydro Testing Corrosion Inhibitor RXSOL 4000 incorporates oxygen scavenger to rapidly remove oxygen, biocide to prevent Microbial Influenced Corrosion (MIC), together with a film forming corrosion inhibitor to combat acid (low pH) corrosion. Hydro Testing Corrosion Inhibitor RXSOL 4000 represents a single stage treatment chemical treatment, for hydrotest and mothball operations. Hydro Testing Corrosion Inhibitor RXSOL 4000 is a completely soluble product in fresh water, seawater and in most oilfield brine solutions. It is, therefore, suitable for use in water injection systems (which have no mechanical deaeration), hydrotest and mothball operations, and as a packer fluid. Hydro Testing Corrosion Inhibitor RXSOL 4000 has been used in a large number of major projects in the North Sea, Latin America and South East Asia.
Product Application:

PERFORMANCE:

CORROSION
: Effectively prevents corrosion due to Carbon Dioxide, inorganic salts, dissolved oxygen & Hydrogen sulphide contamination from sour fluid or bacterial action. The inhibitor acts as a cathodic polarizer

 

MICROBIOLOGICAL GROWTH: Effectively prevents the metabolic function necessary for reproduction of the bacteria cell. Successfully prevents anaerobic/aerobic and sulphate reducing bacteria.

Product Dose:

Hydro Testing Corrosion Inhibitor ( RXSOL 4000 )  can be fed directly or through chemical doses pump. Doses may vary with the quality of water to be treated and the residence time of the water in the system.

Actual consumption is determined under operating conditions.

Recommended Dosage of Hydro Testing Corrosion Inhibitor RXSOL 4000

Hydro Testing Corrosion Inhibitor RXSOL 4000 dosage levels typically are 500ppm for hydrotest operations and between 1000- 4000 ppm when used as a packer fluid inhibitor. The exact dose rate for a specific job would depend on the environment and fluid that the chemical was being deployed into. We are happy to advise on this if required.

Product Note:

Benefit  / Advantage of Hydro Testing Corrosion Inhibitor RXSOL 4000

  • Hydro Testing Corrosion Inhibitor RXSOL 4000 is a liquid multifunctional chemical designed to completely treat hydrostatic test fluid, saltwater packer fluid, saltwater drilling fluid, during Hydro-testing and oil field water injection programme.
  • Hydro Testing Corrosion Inhibitor RXSOL 4000 contains an effective filming corrosion inhibitor, oxygen scavenger and biocide, altogether in a single formulation convenient to dose with single chemical injection pump or skid.
  • Hydro Testing Corrosion Inhibitor RXSOL 4000 is economical to use as handling is limited to one chemical.
  • Rapidly kills Sulphate Reducing (SRB) as well as other offending bacteria that give rise to Microbial Influenced Corrosion (MIC)
  • Mitigates against acid corrosion resulting from residual low pH of surface waters
Product Technical Specification:
 
Form                                         Liquid
Colour Colourless to slightly Yellow
Odour Sharp
Flash Point  > 100C
Density 1.05-1.11 g/cm3 (25C)
pH 3 - 7
 

Non-Flammable

Safe Plant Handling
Low Odor
Provides corrosion protection in the liquid and the vapor phase
When used in hydrostatic testing the product provides protection in liquids below, above and at the liquid levels. Protection of recessed and hard to reach areas. Complicated valves and the interior surfaces of piping and equipment, which are often difficult or impossible to reach, are protected with true Vapor Corrosion Inhibitor action. Can be applied for hydrotest solution, metalworking fluids, coatings, adhesives and water treatment formulations.


 

Remarks:

Risk of serious damage to eyes. In case of contact with eyes, rinse immediately with plenty of water & seek medical advice.  Wear suitable gloves and eye / face protection

prod_useful_area:

The major factor which contributes to the corrosion in hydro-static test water is the dissolved oxygen and dissolved solids do not have much impact on the corrosion rate except the chloride content. The presumptions like not using the corrosion inhibitor if the water is not with high mineral content could beM disastrous as in fact any corrosion process, even a very mild one, will be accompanied by the set up of galvanic cells and formation of corrosion products deposits. Such environment makes the conditions ideal for the corrosion process to continue at accelerated rate once the process fluid will be run through the line.

Product Supply Location:

Hydro Testing Corrosion Inhibitor RXSOL 4000 is Hydro-testing corrosion protection for Pipeline, Tank.  RXSOL 4000 Chemical for conditioning of hydro test water i.e. blend of corrosion inhibitor, one Oxygen scavenger, one scale inhibitor & one biocide manufacturer exporter and supplier Mumbai, Surat, Gandhidham, Chennai, Ennore, Visakhapatnam, Kolkata, Haldia, Paradip, Fujairah, Sharjah, Ajman, Abudhabi, Dubai UAE Middle East, Muscat Oman Sohar

Hashtag: <p> #MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant #Demulsifier #WaterlessHandCleaner #AirC</p>
stock-clearance.png