Buffer Cleaner
Oman Chemical is leading one Largest Supplier, Manufacture a
• Automotive - Closed Circuit Cooling, Dynamometers, Extruders, Molders, Radiators, Welders
• Bottling - CO2 Generators, Heaters, Exchangers, Rinse Tanks, Sterilizers, Washers
. HOUSE HOLD - Dissolves hard and old lime scale deposits from your appliances. It extends the life of the appliance and saves running cost. It can be used in appliances such as Washing Machines, Dish Washers, Geysers, Steam Iron, Coffee Makers, Bath Tubs, Bathroom Fixtures etc.
• Buildings - Chillers, Cooling Towers, Pipework
• Chemicals - Dryers, Extruders, Kettles, Mixers, Reactors, Scrubbers, Vacuum Pumps
• Food - Condensers, Ice Machines, Kathabars, Refrigeration Equipment, Steam Tables
• Manufacturing - Chillers, Compressors, Furnaces, Quenchers, Vacuum Pumps
• Metals - Bearings, Castings, Fans, Hearth & Vacuum Furnaces, Shelters, Sprays
• Mining - Bearings, Conveyors, Filters, Presses, Process Lines, Radiators
• Paper- Calendar Mill Rolls, Caustic Lines, Scrubbers, Compressors, Liquor Tanks, Pulverizers, Vacuum Pumps
• Pharmaceutical- Exchangers, Loop Systems, Kathabars, Pumps, Reactors, Stills, Sterilizers
• Refinery - Compressors, Converters, Crackers, Exchangers, Piping, Pumps
• Rubber/Plastics - Banbury Mixers, Calendar & Mill Rolls, Extruders, Injection Molders, Molds, Temperature Control Units, Throat Coolers, Towers, Tubers
• Steel - Bearings, ConCast Units, Generators, Hearths, Spangle Units, Furnaces
• Textile - Air Washers,Compressors, Condensers, Exchangers, Extruders,Towers
Boilers
Condensers
Filters
Heat Exchangers
Kettles & Tanks
Pipelines
Pots
Reactors
Steam Jackets
Bath Rooms and Showers
Metal Processing and much more!
Applications
Automotive |
Bottling |
Chemicals |
Food |
- Closed Circuit Cooling - Dynamometers - Extruders - Molders - Radiators - Welders |
- CO2 Generators - Heaters - Exchangers - Rinse Tanks - Sterilizers and Washers |
- Dryers - Extruders - Kettles - Mixers - Reactors - Scrubbers - Vacuum Pumps |
- Condensers - Ice Machines - Kathabars - Refrigeration Equipment - Steam Tables |
Manufacturing |
Metals |
Mining |
Paper |
- Chillers - Compressors - Furnaces - Quenchers - Vacuum Pumps |
- Bearings - Conveyors - Fans - Hearth & Vacuum Furnaces - Shelters - Sprays |
- Bearings - Conveyors - Filters - Presses - Process Lines - Radiators |
- Calendar Rolls - Mill Rolls - Caustic Lines - Scrubbers - Compressors - Liquor Tanks - Pulverizers - Vacuum Pumps |
Pharmaceutical |
Refinery |
Rubber & Plastics |
Steel |
- Exchangers - Loop Systems - Kathabars - Pumps - Reactors - Stills - Sterilizers |
- Compressors - Converters - Crackers - Exchangers - Piping - Pumps |
- Banbury Mixers - Calendar & Mill Rolls - Extruders - Injection Molders - Molds - Temperature Control - Units - Throat Coolers - Towers and Tubers |
Bearings ConCast Units Generators Hearths Spangle Units Furnaces |
Textile |
Utilities |
Other Applications |
|
- Air Washers - Compressors - Condensers - Exchangers - Extruders and Towers |
- Boilers - Turbines - Transformers - Cooling Towers - Air Compressors - Hydrogen Coolers - Lube Oil Heat Exchangers |
- Ball Mills - Demisters - Evaporators - Locomotives - Absorption Units - Diesel Generators - Induction Furnaces |
PHYSICAL STATE |
: LIQUID, DARK LIQUID |
BOILING POINT |
: 105° C |
SOLUBILITY IN WATER |
: MISCIBLE |
SPECIFIC GRAVITY, (WATER=1) | :1.03 @ 25 DEGREE C |
VAPOR PRESSURE |
: 20.1mmHg @ 25 DEGREE C |
VAPOR DENSITY, (AIR=1): | : .62 @ 25 DEGREE C |
pH |
: UNREADABLE, GENERALLY < 3 |
EVAPORATION RATE, (WATER=1): | :SLOW |
LIME Marine does not corrode, erode, attack, oxidize or have other deleterious affects on virtually any metal or materials found in marine water systems such as: BRASS, IRON, LEATHER, CERAMIC ,WOOD, FIBER, PLASTICS FIBERGLASS, COPPER, STEEL, TITANIUM ,COPPER NICKEL ,RUBBER, GLASS, GELCOATS PAINTED SURFACES.
LIME Marine is an electrolyte, as are most cleaning agents. An electrolyte is any liquid that will transfer small electrical currents. Examples: salt water, vinegar, Coca-Cola. An electrolyte may cause plating in some types of equipment. This means a transfer of small amounts of one metal onto another metal according to the galvanic corrosion chart. In some instances, a thin coating of copper may be plated onto a steel drum while circulating an electrolyte such as RXLYME Marine. The only time plating occurs is when two dissimilar metals are in an electrolyte solution.
It is recommended, but not mandatory, that the LIME Marine solution be thoroughly mixed before using. Some settling of a dark precipitate may occur, resulting in an amber colored liquid, but has no negative affects upon the performance of the solution.
It is very Powerful Aluminium Cleaner
Appearence | liquid |
Colour | light red |
Odour | mild |
Melting point: | not applicable |
Flash point | not applicable |
Spontaneous ignition | not applicable, no Danger of explosion |
This product is avilable with all our associated ship chandlers of INDIA and Middle East by product code no RXSOL-16-1028-025.
we are manufactrer of RXSOL-16-1028-025 , and supplier in kakinada, Visakhapatnam, Vizag, Mumbai, Goa, Surat, Gandhidham, Kandla, Mundra, Chennai, Ennore, Kolkata, Haldia, Pirpav, Fujairah, Dubai, Sharjah, Abu Dhabi and Gulf.
RXSOL brand Aluminium Cleaner exporter for TURKEY, Australia.
Do not allow concentrate to come in contact with skin. Avoid contact Eyes and clothing. Alu Brightener is a concentrated liquid acid formulated .
First Aid: Skin Contact: Wash area with soap and water. Rinse with a solution of vinegar and water. If irritation persists seek medical attention
Eye Contact: Flush with water for 15 minutes. Obtain medical attention
Ingestion: Drink several glasses of fruit juice. Do not induce vomiting. Obtain immediate medical attention.
Property | Value |
Density, lbs/gal 68°F (20°C)
|
8.6 lb/gal. |
Pour Point °F | -30 |
Ionic Charge | Cationic |
pH | 2.5-3.5 |
15% HCl | Soluble |
Solubility ,Water | Soluble |
Hydrocarbon | Dispersable |
Appearance | liquid |
Appearance |
Yellowish Powder |
Density |
in g/cm3 at 15°C: 1.2 |
Flash Point |
(PMCC) in °C: N/A |
pH |
in 10 wt-%: 1.1 |
Compatibility |
|
Metal |
Avoid Aluminium, Zinc, Tin and their alloys and Galvanised surfaces. |
Rubber |
No known effect. |
RXSOL DESCALE POWDER is chemical compound and should be handle with all chemicals handling precaution like use chemical protective goggle, Hand gloves etc... For more details pl. refer RXSOL product MSDS.
Thiourea, also chemically named as Thiocarbamide, is a nitrogen and sulfur containing compound. It has three functional. groups, amino, imino and thiol, each with important biological roles.
THIOUREA AR is used in vulcanization accelerators. It is used as an auxiliary agent. It is used in silver – gelatin photographic prints. It is used in diazo paper, light – sensitive photocopy paper.
The percentages of nitrogen and sulfur in all the samples synthesized from thiourea were roughly 5–20 wt. % and 3–8 wt. % even after washing with hot water, respectively.
PHYSICAL STATE |
: LIQUID, DARK LIQUID |
BOILING POINT |
: 105° C |
SOLUBILITY IN WATER |
: MISCIBLE |
SPECIFIC GRAVITY, (WATER=1) | :1.03 @ 25 DEGREE C |
VAPOR PRESSURE |
: 20.1mmHg @ 25 DEGREE C |
VAPOR DENSITY, (AIR=1): | : .62 @ 25 DEGREE C |
pH |
: UNREADABLE, GENERALLY < 3 |
EVAPORATION RATE, (WATER=1): | :SLOW |
LIME Marine does not corrode, erode, attack, oxidize or have other deleterious affects on virtually any metal or materials found in marine water systems such as: BRASS, IRON, LEATHER, CERAMIC ,WOOD, FIBER, PLASTICS FIBERGLASS, COPPER, STEEL, TITANIUM ,COPPER NICKEL ,RUBBER, GLASS, GELCOATS PAINTED SURFACES.
LIME Marine is an electrolyte, as are most cleaning agents. An electrolyte is any liquid that will transfer small electrical currents. Examples: salt water, vinegar, Coca-Cola. An electrolyte may cause plating in some types of equipment. This means a transfer of small amounts of one metal onto another metal according to the galvanic corrosion chart. In some instances, a thin coating of copper may be plated onto a steel drum while circulating an electrolyte such as RXLYME Marine. The only time plating occurs is when two dissimilar metals are in an electrolyte solution.
It is recommended, but not mandatory, that the LIME Marine solution be thoroughly mixed before using. Some settling of a dark precipitate may occur, resulting in an amber colored liquid, but has no negative affects upon the performance of the solution.
Typical descaling cleaning procedure :
1st Stage : Take ‘RXSOL-11-1053-010’ weblink ( http://rxmarine.com/Alkaline-Descaler ) and mix with water in the ratio of 1:6 (One litre of RXSOL-1053 and six litres of water). Circulate the solution or immerse the equipment in this solution for 2 hrs. This will be helpful in loosening the hard deposited scale.
RXSOL-40-1048-025 should not be used on Aluminium, Zinc, Tin, or any Galvanized Surfaces for which a special grade cleaner should be used. Chemical Cleaning Module Rx cleansers has developed a 280 litres capacity cleaning module, primarily designed for use with chemical acid solvents for descaling boilers, calorifiers, heat exchangers & other types of equipment where rust & scale form RXSOL-11-1008--DC Boilers, See Rx cleansers Practical Application Manual.
Formation of Calcium Sulfate is main cause for SCALE formation :::
The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation. Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously. There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.
In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices. The low hardness levels largely preclude calcium sulfate boiler scale. By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal. Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated. Calcium sulfate scale deposition can result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals. Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger.
Sulfate content can be calculated in Laboratory by using this method ::: http://rxmarine.com/SULFATE-TEST-KIT