Isothiazolinone CMIT MIT 14

Size:

Color:

Product Short Description: Isothiazolinone CMIT/MIT 14 is high performance, broad spectrum, antimicrobial agents based on the proven isothiazolone chemistry.
Product Technical Specification:

 

Appearance Light yellow liquid
Active Ingredient 14%
Viscosity 16 cps @ 25°C
pH 2.0-4.0
Specific Gravity (g/ml) at 20°C

1.27-1.33

5-Chloro-2-Methyl-4-Isothiazoline-one

10.1 - 11.3

Magnesium (%) 4.2 - 5.5
2-Methyl-4-Isothiazoline-3-one 3.0 - 4.1

 

Remarks:
Images: Alt



MAGNESIUM NITRATE HEXAHYDRATE

Size:

Color:

Product Short Description: MAGNESIUM NITRATE HEXAHYDRATE
Product Technical Specification:
Name of Product : 
(Commercial Grade)
Technical name : Magnesium Nitrate Hexahydrate
H.S. Code : 2834.29.2000
Formulae : Mg(NO3)2.6H2O
Excise Code : 2834.29.20
Magnesium : 9.2 % min ( typically 9.4 %)
Nitrate NO3 : 47.9 % min ( typically 48.5 %)
Percentage by mass
Ammonia : less than 0.02 %
 
Product Name : MAGNESIUM NITRATE -HEXAHYDRATE
CAS Number : 13446-18-9
Molecular Weight : 256.41
Min Assay Purity as percentage Magnesium Nitrate Mg (No3)2.6H2O) : 98 - 99%
Assay as MgO : 15.50%
N (Nitrogen) : 10.50%
Apperance : White crystalline powder/ white crystals
Chlorides : 0.01 % Max
Sulphates : 0.01% Max
Calsium (Ca) : 0.05% Max
Feric (Fe) : 0.02% Max
Heavy Metal : 0.01% Max
pH of 5% solution : 5 - 7
Solubility in water : Highly soluble
UN Class : 5.1
UN No :1474
Packing Group : III
IMDG No : 5159
 
Remarks:
Images: Alt



Hydro Testing Corrosion Inhibitor

Size:

Color:

Product Short Description: Hydro-testing corrosion protection for Pipeline, Tank
Product Technical Specification:
 
Form                                         Liquid
Colour Colourless to slightly Yellow
Odour Sharp
Flash Point  > 100C
Density 1.05-1.11 g/cm3 (25C)
pH 3 - 7
 

Non-Flammable

Safe Plant Handling
Low Odor
Provides corrosion protection in the liquid and the vapor phase
When used in hydrostatic testing the product provides protection in liquids below, above and at the liquid levels. Protection of recessed and hard to reach areas. Complicated valves and the interior surfaces of piping and equipment, which are often difficult or impossible to reach, are protected with true Vapor Corrosion Inhibitor action. Can be applied for hydrotest solution, metalworking fluids, coatings, adhesives and water treatment formulations.


 

Remarks:

Risk of serious damage to eyes. In case of contact with eyes, rinse immediately with plenty of water & seek medical advice.  Wear suitable gloves and eye / face protection

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



FERRO IOD CLEAN

Size:

Color:

Product Short Description: FERRO IOD CLEAN removes, dissolves and disperses iron oxide deposits from diesel cooling water systems while providing a temporary passivating film to protect the base metal from corrosion.
Product Technical Specification:

TYPICAL PROPERTIES

Appearance : Light yellow liquid
Specific Gravity @25° C : 1.14
Flash Point : None
Freeze Point : -8° C
Water Solubility : Completely Soluble
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Corrosion Inhibitor OPEN Cooling System

Size:

Color:

Product Short Description: Corrosion Inhibitor for OPEN CIRCULATING SYSTEM
Product Technical Specification:
PHYSICAL CHARACTERICS 
Appearance   : Clear Liquid - Also available in PINK colour
Specific Gravity  : 1.10 to 1.20
Flash Point  : Non Flammable 
Freezing Point  : 0 Degrees Cent. 
Remarks:
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System  product does not require additional acid treatment. 
ADVANTAGES of RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System
Clean Surfaces  - Maximum heat transfer  -
Its regular doses increases Higher efficiency
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System  - Reduced Maintenance down time  - Increased production
Non Toxic  - Easy and Safe in use 
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



RXSOL BIOCIDE MAR

Size:

Color:

Product Short Description: Cooling Water Biocide to control microbiological growth
Product Technical Specification:
BIOCIDE  properties

Colour ::: Yellowish
Density ::: More then Water ( 1 )
Physical State ::: Liquid
pH ::: Alkaline range 10 in  diluted solution
Remarks:

Avoid any contact with DRINKING water.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



ROCCOR NB RXSOL With Indicator

Size:

Color:

Product Short Description: Usefull for use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets.
Product Technical Specification:
Remarks:
Images: Corrosion Inhibitor
Get MSDS
Get Technical Bulletin
Connect On Whats App



ROCCOR NB Corrosion Scale Inhibitor Liquid

Product Short Description: Unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants , dispersant and buffer solution of non carbonate.Usefull for use in high or low temperature closed cooling water syste
Product Technical Specification:

RX MARINE INTERNATIONAL are continiously working in water treatement sector, And developed many unique product to avoid corrosion and scale depositon in cooling water system. Here I wants to keep our experiment results with you.Corrosion inhibitor for closed cooling systems containing molybdate/phosphonate ( RXSOL-40-4018-025 ). Sodium molybdate has the advantage in that the dosing of lower ppm's of molybdate allow for lower conductivity of the circulating water. Sodium molybdate at levels of 50-100 ppm offer the same levels of corrosion inhibition that sodium nitrite at levels of 800+ ppm. By utilizing lower concentrations of sodium molybdate, conductivity is kept at a minimum and thus galvanic corrosion potentials are decreased.

Remarks:

Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate. hours> 4. Re check the readings. and record. 5 track these readings
for a period of time.

If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.

Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-Algaecide

Images: Nitrite Borax Corrosion Inhibitor
Get MSDS
Get Technical Bulletin
Connect On Whats App



ROCCOR NB RXSOL Colour Indicator

Product Short Description: Corrosion Inhibitor for Water Systems having unique formulation with highly concentrated liquid cooling treatment compound
Product Technical Specification:
Remarks:

Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate. hours> 4. Re check the readings. and record. 5 track these readings
for a period of time.

If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.

Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-Algaecide

Images: Corrosion Inhibitor Water Treatment Chemicals manufacturer
Get MSDS
Get Technical Bulletin
Connect On Whats App



Anti Corrosion and Anti Scaler Chiller TRAC 109

Size:

Color:

Product Short Description: Unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants , dispersant and buffer solution of non carbonate.Usefull for use in high or low temperature closed cooling water syste
Product Technical Specification:

RX MARINE INTERNATIONAL are continiously working in water treatement sector, And developed many unique product to avoid corrosion and scale depositon in cooling water system. Here I wants to keep our experiment results with you.Corrosion inhibitor for closed cooling systems containing molybdate/phosphonate ( RXSOL-40-4018-025 ). Sodium molybdate has the advantage in that the dosing of lower ppm's of molybdate allow for lower conductivity of the circulating water. Sodium molybdate at levels of 50-100 ppm offer the same levels of corrosion inhibition that sodium nitrite at levels of 800+ ppm. By utilizing lower concentrations of sodium molybdate, conductivity is kept at a minimum and thus galvanic corrosion potentials are decreased.

Remarks:

Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate. hours> 4. Re check the readings. and record. 5 track these readings
for a period of time.

If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.

Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-Algaecide

Images: Alt
stock-clearance.png