Corrosion Inhibitor for Diesel Cooling Water Treat

Size:

Color:

Product Short Description: Anti-Scalant for use in closed cooling water systems , for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is a concentrated liquid , also used as a corrosion inhib
Product Technical Specification:

SPECIFICATION / HANDLING
Color                           : Odour Pink/ red (Colour changes of the product cannot be excluded the effects will however not impaired.)
Sp. Gravity                  : 1.1 to 1.25
pH                               : Alkaline (11.3 – 11.5)
None. Rxsol-2000 is an alkaline product & should be handled like other chemical Avoid contact with Eyes, Skin, in case of contact, wash with copious amounts of water immediately.
Freezing Point - 17 0 c


Nitrite (as PPM NO2)       0                   100-200      300-600        700-900      1100-1300      1440-2400
RXSOL CIDC /1000L      13.0               11.3              8-10               5-7               1.5-3.5              0

Remarks:

METHOD OF USE
1. Properly clean the system with water and alkaline liquid, if necessary.
2. Add 0 .15-1.5 % of RXSOL CIDC in the system or recommended Nitrite level 1400 – 2500 ppm can be measured and controlled by any standard RXSOL test kit for Nitrite, Chloride test also helps to detect excess contamination to maintain acceptable levels. when the product is dosed as recommended limit By buffering action of RXSOL CIDC, pH should be maintained between 8.3 and 10 by the treatment.

Images: Alt



BIOCIDE MICRO Cooling Water 20 Ltr

Size:

Color:

Product Short Description: Strong algae depressant fully compatible with alkalizing and flocculating agents normally used in cooling / boiler water. Algae growth is the main cause of colour in water. Routine and weekly additions of RXSOL-40-4009-020 establish a buffer action to control very rapid algae growth.
Product Technical Specification:
Remarks:
Images: Alt



Biological Guard Antifouling

Size:

Color:

Product Short Description: Anti fungal based dispersing cleaner for the control of fouling by marine growth such as algae, shellfish, mussels, barnacles and micro-organisms and fungal growth in the sea water side of coolings systems. Due to its molecular firm foaming properties, it
Product Technical Specification:
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Corrosion Inhibitor Nitrite - Phosphonate for CLOSED LOOP

Size:

Color:

Product Short Description: Closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets.
Product Technical Specification:
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Hardness Control Boiler Treatment

Size:

Color:

Product Short Description: Phosphate Boiler Water Treatment Hardness Control is a white dry powder Phosphate Boiler Water Treatment product used for the reduction of hardness in boilers. Hardness Control is highly soluble in water and It will precipitate calcium hardness as a non-a
Product Technical Specification:

Sampling And Testing

A sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Rxsol Hardness Test Kit instructions and fill the Boiler Water Log Form according to result results. It is important that regular testing is carried out to ensure levels of treatment are correct.

Physical Properties :

Appearance        :White powder
Corrosive action  : non
pH 1% solution   : 8,8
Flash point         : none

Remarks:

A precipitant designed to elimate scale deposits and lower the hardness of water in boilers with working pressure up to 60 bars.

It is used in conjunction with alkaline liquid to prevent calcium scale deposits. Both products are used in our standard boiler water treatment programs for low-pressure boiler systems (0-32 bar) and medium-pressure steam propulsion vessels (32-60 bar).

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



BIOCIDE

Size:

Color:

Product Short Description: Very effective controller of BACTERIA in water system.
Product Technical Specification:

Appearance Clear, colorless liquid

Physical State Liquid

Color Colorless

Odor Characteristic Odor

Odor threshold Not applicable

pH <= 3.7

Melting point/freezing point -22 °C

Boiling Point/Range 105 °C

Flash point Not flammable

Evaporation Rate No information available

Flammability (solid, gas) Not flammable

Flammability Limit in Air Not applicable

Upper flammability limit:

Lower flammability limit:

Vapor pressure 26 mm Hg @ 30 °C

Vapor density No information available

Density 1.10 g/cm³ @ 20ºC

Specific gravity 1.10

Water solubility completely soluble

Solubility in other solvents No information available

Partition coefficient log Kow = -1.5 @ 20 °C

Autoignition temperature Not combustible

Decomposition temperature 100 °C

Viscosity, kinematic 1.06 cP @ 20 °C

Viscosity, dynamic No information available

Explosive properties No information available

Oxidizing properties Strong oxidizer

Molecular weight 34

Bulk density Not applicable

Remarks:
Hashtag: #MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant #Demulsifier #WaterlessHandCleaner #AirC
Images: Alt