Corrosion Inhibitor for Gas Compressor

Size:

Color:

Product Short Description: Corrosion Inhibitor for Gas Compressor
Product Technical Specification:

 

Test type ASTM method Corrosion Inhibitor
ISO VG   100
     
Water content, ppm D6304 20
Acid number TAN, mgKOH/g D974 1.32
Flash and fire point D92  
Flash point, °C   243
Ignition temperature, °С   268
Kinematic viscosity, cSt D445  
40°C   107.2
100°C   11.7
Viscosity index D2270 116
Pour point, °C D97 -37
Demulsibility D1401  
Oil-Water-Emulsion (time in minutes)   39-40-1 (10)
Volatility by NOACK D972  
Losses in % mass   2.9 
Copper Tape Corrosion D130  
100°C, 3 hours   1A
Corrosion D665  
A - in distilled water   Pass
B - in sea water   Pass

These products are also available in other viscosity grades and packaging. Additional test results are available upon request. 

 

 

Remarks:
Images: Alt



Corrosion inhibitor closed cooling systems Molybdate Phosphonate

Size:

Color:

Product Short Description: RXSOL-40-4018 is a superior molybdate/phosphonate based corrosion inhibitor developed for use in closed cooling water systems. RXSOL-40-4018 prevents corrosion and deposits in closed and aerated cooling water systems. RXSOL-40-4018 contains inhibitors for
Product Technical Specification:

Molybdate-Phosphate for Closed Circulation Machinery Cooling Corrosion inhibitor.

Appearance

BROWN COLOURED HAZY LIQUID

Boiling point [oC]

100

C Density [kg/m3]

1.12 - 1.20

Flashpoint[oC] TCC

NONE Vapour pressure [mm Hg]

Pour point [oC]

NONE Vapour density [a ir=1]:

Auto-ignition temp [oC] NONE 
Expl.omr. [vol%] Solubility in water [w-%]: 100%
pH : 12.0  on 1% Dilution - 11
Solubility  100% in Distilled water
Rel. evaporation Rate. N/A
Recommend Dosage  ppm LEVEL 1460 to 2070
Soluble in organic solvent: None
Remarks:

Use proper chemical protective hand gloves and Eye Goggles.

Images: Alt



Corrosion Inhibitor Closed Open Cooling Water System

Size:

Color:

Product Short Description: RXSOL-40-4028 creates an insoluble polymeric surface complex on copper and its alloys, and also reacts with copper in solution. RXSOL-40-4028 also works synergistically with other inhibitors to effectively control the corrosion of steel and aluminium in the system.
Product Technical Specification:
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Acid corrosion Inhibitor RXSOL 213

Size:

Color:

Product Short Description: The addition of Acid corrosion Inhibitor RXSOL 213, inhibitors to hydrochloric acid solution provides maximum protection for equipment during,The removal of lime deposits or water scale from power plant boilers and piping systems and from evaporating equi
Product Technical Specification:

ACID inhibitor for HCl, Hydrochloric Acid. 

During Acidization corrosion prevention must required to protect metal surface from ACID effect. Inhibited hydrochloric acid  (HCl), HF doesn't damage metal surface. 
Remarks:

Acids and corrosive materials are used to enhance production and to stimulate reservoirs therefore special care is required to ensure that casing, tubing strings and downhole equipment are not damaged. Blend of ACID with Acid corrosion Inhibitor RXSOL 213 protect your downhole equipment and metal tubulars.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Corrosion Inhibitor for metal RUST Preventive

Size:

Color:

Product Short Description: Metal RUST Prevantiveprotective coating is thin, transparent, clear and slightly oily.
Product Technical Specification:

TYPICAL PHYSICAL AND CHEMICAL PROPERTIES:

Physical State : Liquid
Solubility in Water : Insoluble
Boiling Point : >190°F
Flash Point, COC : 190°F
Total Chlorine/Chloride, wt% : 0.00/0.00ppm
Appearance and Odor : Opaque/Chemical
Specific Gravity : 0.82
VOC Content (ASTM D2369) : 58%
pH Concentrate : NA
Total Sulfur, wt% : 0.00
 
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



RXSOL 2000

Size:

Color:

Product Short Description: Unique formulation with organic Corrosion Inhibitors , Anti-Scalant for use in closed cooling water systems as a high temperature coolant for internal combustion stationers, engines, machinery, snow melting systems, industrial heat transfer fluids , for p
Product Technical Specification:

This product also contails Benzotriazole , which is very effective  effective corrosion inhibitor for copper and its alloys by preventing undesirable surface reactions. It is known that a passive layer, consisting of a complex between copper and benzotriazole, is formed when copper is immersed in a solution containing benzotriazole. The passive layer is insoluble in aqueous and many organic solutions. There is a positive correlation between the thickness of the passive layer and the efficiency of preventing corrosion. The exact structure of the copper-BTA complex is controversial and many proposals have been suggested.


AREAS  OF APPLICATION :

•Automobile.
•Heavy Equipment.
•Generators, Marine Engines.
•Ship or Rig Equipment.

 

Remarks:
Why RXSOL 2000 Corrosion Inhibitor and Antiscalant?
 
 
RXSOL 2000 is specialized formulation of corrosion inhibitor to protect cast iron diesel engine cooling systems
RXSOL 2000 Contains Antiscalant to stop scale and sludge formation 
Keep engine free from SCALE and corrosion which Prevents Engine overheating
RUST formation and Scale deposition damaging the metal surface by pitting and corrosion, RXSOL 2000 helps against corrosion and scale
RXSOL 2000 is compatible with  hoses, diesel liner seals and ‘O’rings
Most popular Corrosion Inhibitor and antiscalant for CAST IRON DIESEL ENGINE cooling system.
 
Engine Cooling system corrosion inhibitor and antiscalant manufacturer and supplier in India, UAE Middle East, Muscat Oman, Kenya Nairobi, Sudan, YEMEN
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Corrosion Inhibitor for Multi Metal Cooling Water

Size:

Color:

Product Short Description: Alkaline Corrosion Inhibitor blend for Metal protection inside the CLOSED circulating system
Product Technical Specification:
Remarks:

Keep in a tightly closed container in storage closed area . Recommended storage temperature is 500C
 

Images: Alt
stock-clearance.png