AC2 DESCALEX Powder

Size:

Color:

Product Short Description: RXSOL AC-2 chemical is specialized detergent based acid with corrosion inhibitor for evaporators, boilers, heat exchangers, tanks, pipes, and other heat transfer equipment
Product Technical Specification:

 

Appearance

Yellowish Powder

Density

in g/cm3 at 15°C: 1.2

Flash Point

(PMCC) in °C: N/A  

pH

in 10 wt-%: 1.1

Compatibility

 

Metal

Avoid Aluminium, Zinc, Tin and their  alloys and Galvanised surfaces. 

Rubber

No known effect. 

Remarks:

RXSOL DESCALE POWDER is chemical compound and should be handle with all chemicals handling precaution like use chemical protective goggle, Hand gloves etc... For more details pl. refer RXSOL product MSDS. 

Images: Alt



FORMIC ACID

Size:

Color:

Product Short Description: Formic acid is an effective chemical for removing scale from equipment and surfaces due to its ability to dissolve calcium, magnesium, carbonate, and iron
Product Technical Specification:
Remarks:
Images: Alt



Descalex Polymer Heat Exchanger

Size:

Color:

Product Short Description: Free from HCl, Safe and effective way to remove scale deposits from all types of water-cooled and water-heated equipment.
Product Technical Specification:

Typical descaling cleaning procedure :

1st Stage : Take ‘RXSOL-11-1053-010’ weblink ( http://rxmarine.com/Alkaline-Descaler )   and mix with water in the ratio of 1:6 (One litre of RXSOL-1053 and six litres of water). Circulate the solution or immerse the equipment in this solution for 2 hrs. This will be helpful in loosening the hard deposited scale. 

2nd Stage : Circulate the entire system with ample fresh water, at least for 10 minutes.
 
3rd Stage : Take ‘RXSOL-40-1048-025’ and mix with water in the ratio of 1:6 (One litre of RXSOL-1048 and six litres of water). Circulate the solution or immerse the equipment in this solution for 6-8 hrs.
 
4th Stage : Flush the entire system with ample fresh water, at least for  20 minutes.
 
5th Stage :  Take ‘RXSOL-11-1053-010’ weblink ( http://rxmarine.com/Alkaline-Descaler )  and mix with water in the ratio of 1:6 (One litre of NF and six litres of water). Circulate the solution or immerse the equipment in this solution for 2 hrs.

 
6th Stage : Flush the entire system with ample fresh water, till the ph value of outlet water  match as fresh water. 
Remarks:

RXSOL-40-1048-025 should not be used on Aluminium, Zinc, Tin, or any Galvanized Surfaces for which a special grade cleaner should be used. Chemical Cleaning Module Rx cleansers has developed a 280 litres capacity cleaning module, primarily designed for use with chemical acid solvents for descaling boilers, calorifiers, heat exchangers & other types of equipment where rust & scale form RXSOL-11-1008--DC Boilers, See Rx cleansers Practical Application Manual.

Formation of Calcium Sulfate is main cause for SCALE formation :::

The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation.  Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously.  There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.

In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices.  The low hardness levels largely preclude calcium sulfate boiler scale.    By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal.  Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated.  Calcium sulfate scale deposition can  result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals.  Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger.  

Sulfate content can be calculated in Laboratory by using this method ::: http://rxmarine.com/SULFATE-TEST-KIT

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



LIME Marine Water Scale Remover

Size:

Color:

Product Short Description: LIME Marine is a safe, biodegradable marine descaler developed to dissolve problematic fouling mediums including calcium, rust, mussels, barnacles, tiger shells and other scale formed mineral deposits that hinder the performance of vital water systems
Product Technical Specification:

PHYSICAL STATE

: LIQUID, DARK LIQUID
BOILING POINT

: 105° C

SOLUBILITY IN WATER

: MISCIBLE

SPECIFIC GRAVITY, (WATER=1) :1.03 @ 25 DEGREE C
VAPOR PRESSURE

: 20.1mmHg @ 25 DEGREE C

VAPOR DENSITY, (AIR=1): : .62 @ 25 DEGREE C
pH

: UNREADABLE, GENERALLY < 3

EVAPORATION RATE, (WATER=1): :SLOW
Remarks:

LIME Marine does not corrode, erode, attack, oxidize or have other deleterious affects on virtually any metal or materials found in marine water systems such as: BRASS, IRON, LEATHER, CERAMIC ,WOOD, FIBER, PLASTICS FIBERGLASS, COPPER, STEEL, TITANIUM ,COPPER NICKEL ,RUBBER, GLASS, GELCOATS PAINTED SURFACES.

LIME Marine is an electrolyte, as are most cleaning agents. An electrolyte is any liquid that will transfer small electrical currents. Examples: salt water, vinegar, Coca-Cola. An electrolyte may cause plating in some types of equipment. This means a transfer of small amounts of one metal onto another metal according to the galvanic corrosion chart. In some instances, a thin coating of copper may be plated onto a steel drum while circulating an electrolyte such as RXLYME Marine. The only time plating occurs is when two dissimilar metals are in an electrolyte solution.

It is recommended, but not mandatory, that the LIME Marine solution be thoroughly mixed before using. Some settling of a dark precipitate may occur, resulting in an amber colored liquid, but has no negative affects upon the performance of the solution.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Hydrocarbon Scale Deposit Remover

Size:

Color:

Product Short Description: Removal of Hydrocarbon Scale deposit from heat exchanger tube...
Product Technical Specification:
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Hydrochloric Acid Lab Grade

Size:

Color:

Product Short Description: HCl Lab Reagent
Product Technical Specification:

Product Specification:

Product Number:

258148

CAS Number:

7647-01-0

MDL:

MFCD00011324

Formula:

HCl

Formula Weight:

36.46 g/mol

 

TEST  Specification

Appearance (Clarity)

Clear

Appearance (Color)

Colorless

Appearance (Form)

Liquid

Free from Suspended Matter or Sediment Color Test

<_ 10 APHA

Titration with NaOH

<_ 0.01 ppm

Arsenic (As)

<_ 0.01 ppm

Bromide

<_ 0.005 %

Iron (Fe)

<_ 0.2 ppm

Heavy Metals (as Pb)

<_ 1 ppm

Sulfate

<_ 1 ppm

Residue on Ignition (ppm)

<_ 5 ppm

Extractable Organic Substance  Not Greater Than 5 ppm

Pass

Free Chlorine

<_ 1 ppm

Ammonium

<_ 3 ppm

Sulfite (ppm)

<_ 1 ppm

Meets ACS Requirements 10th Edition

Current ACS Specification

Storage Life

 3 Years

 
Remarks:

First Aid

Eye Contact - The eyes should be immediately flushed with large amounts of water continuously for at least 15 minutes. Get immediate medical attention. It is necessary to hold the eyelids apart while flushing to ensure complete irrigation of the eye. Washing eyes within several seconds is essential to achieve maximum effectiveness. A delay of a few moments or incomplete washing can result in partial or permanent blindness. Never attempt to neutralize hydrochloric acid in the eyes with chemicals. Do not apply oils or ointments unless specifically prescribed by a physician.

Skin Contact - Flush the area of contact with large amounts of water. Contaminated clothing should be removed while underneath a safety shower. Get immediate medical attention. Do not attempt to neutralize the acid with alkaline solutions. No oils or ointments should be applied unless specified by a physician.

Inhalation Remove individual to fresh air and get immediate medical attention. In cases of severe exposure, humidified oxygen should be administered by someone medically trained to administer oxygen. If respiration or pulse has stopped, have a trained person administer Basic Life Support (Cardio-Pulmonary Resuscitation and/or Automatic External Defibrillator) and CALL FOR EMERGENCY SERVICES IMMEDIATELY.

Ingestion - Get immediate medical attention. If individual is a fully conscious, give large amount of water. Do not use sodium bicarbonate in an attempt to neutralize the acid. Do not induce vomiting. Never give anything by mouth to an unconscious person. 

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



RXSOL Zyme Descaler 25 Ltr

Size:

Color:

Product Short Description: The environmentally friendly and efficient treatment for urine scale build-up in vacuum pipes.This Product prevents scale and keeps sewage flowing freely. Routine use of Product puts an end to scale altogether.
Product Technical Specification:
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Alkaline Descaler 25 Ltr

Size:

Color:

Product Short Description: Strongly surface conditioner and cleaner designed to descale , concentrated liquid compound developed for rapid and through cleaning of heat transfer surfaces by chemically removing rust and water scale.
Product Technical Specification:
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Scale Mineral Cleaner

Size:

Color:

Product Short Description: Safe Acid Mineral Cleaner Very effective products to remove MINERAL SCALE deposits from SURFACES
Product Technical Specification:
Remarks:

Suggestion ::: Our daily descaling works helps to share helpful tricks to dissolve hard scale easily, Always use 5-10 %  our new generation hard scale deposit remover powder RXSOL-11-1102-025 . Addition of RXSOL-11-1102-025 helps to clean 100% scale from system .

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Scale Remover Silica Hard water

Size:

Color:

Product Short Description: This is powerfull concentrated and newly developed silica scale cleaner to clean hard silica water scale. Formation of Silica Scale stop heat transmission from heat exchanger, condenser tubes and boiler tubes. New Generation formula of Silica Scale Removal makes silica and silicate deposit removal
Product Technical Specification:

Compatibility: 
Silica Scale remover is inhibited with corrosion inhibitors so it can be used on most common metals such as ms, ss, Cast Iron, Copper, copper alloys and aluminum but not on galvanized surfaces. 

Remarks:

Silica scale deposits removal always be challenging task. RXSOL-11-1102-025 having strong new generation formula to clean process equipment.

Never use silca scale remover with glass equipment as this product has ability to dissolve glass or glasswares.

Images: Alt
stock-clearance.png