LIME Marine Water Scale Remover

Size:

Color:

Product Short Description: LIME Marine is a safe, biodegradable marine descaler developed to dissolve problematic fouling mediums including calcium, rust, mussels, barnacles, tiger shells and other scale formed mineral deposits that hinder the performance of vital water systems
Product Technical Specification:

PHYSICAL STATE

: LIQUID, DARK LIQUID
BOILING POINT

: 105° C

SOLUBILITY IN WATER

: MISCIBLE

SPECIFIC GRAVITY, (WATER=1) :1.03 @ 25 DEGREE C
VAPOR PRESSURE

: 20.1mmHg @ 25 DEGREE C

VAPOR DENSITY, (AIR=1): : .62 @ 25 DEGREE C
pH

: UNREADABLE, GENERALLY < 3

EVAPORATION RATE, (WATER=1): :SLOW
Remarks:

LIME Marine does not corrode, erode, attack, oxidize or have other deleterious affects on virtually any metal or materials found in marine water systems such as: BRASS, IRON, LEATHER, CERAMIC ,WOOD, FIBER, PLASTICS FIBERGLASS, COPPER, STEEL, TITANIUM ,COPPER NICKEL ,RUBBER, GLASS, GELCOATS PAINTED SURFACES.

LIME Marine is an electrolyte, as are most cleaning agents. An electrolyte is any liquid that will transfer small electrical currents. Examples: salt water, vinegar, Coca-Cola. An electrolyte may cause plating in some types of equipment. This means a transfer of small amounts of one metal onto another metal according to the galvanic corrosion chart. In some instances, a thin coating of copper may be plated onto a steel drum while circulating an electrolyte such as RXLYME Marine. The only time plating occurs is when two dissimilar metals are in an electrolyte solution.

It is recommended, but not mandatory, that the LIME Marine solution be thoroughly mixed before using. Some settling of a dark precipitate may occur, resulting in an amber colored liquid, but has no negative affects upon the performance of the solution.

Images: Alt



Corrosion Inhibitor 1304

Size:

Color:

Product Short Description: It is a n Anti-Agglo merate Hydr ate Inhibitor that effectively p r events gas h ydrates forming blockages.
Product Technical Specification:
Remarks:
Images: Alt



Pet Coke Remover

Size:

Color:

Product Short Description: Innovative, concentrated liquid product specifically engineered to attack, penetrate and remove Coal Carbon, pet coke, lime deposition
Product Technical Specification:

PROPERTIES

Pet Coke Remover is a concentrated liquid solution containing powerful surface active agents, a corrosion inhibitor and aqueous chemical agents.
Appearance / Color : Clear, light yellow liquid.
Specific gravity         : 1.1–1.2 gr/cm3 at 20°C
pH                              : 11.5–12.5


 

Remarks:

Pet Coke STAIN removal concept - 
Coal and petcoke leaves stain,  its removal is important task during hold cleaning operation. Our expert has 2 suggestion for removal of such stain from the surface. 

1st one to use RX Tuff heavy-duty alkaline cleaner, which can apply as an emulsion, need time to take effect and are rinsed away with seawater. More than one application will be needed to remove stubborn stains. 

2nd one solution is much more effective than 1st one step. Here our expert suggests using New ORG on the spotted area where the residue is tightly deposited on the surface. " New ORG -RXSOL-20-2020-025 " this product is specialized to react with oily residue where any alkaline cleaner fails to emulsify. Uses of New ORG  chemicals for stain removal/cleaning principally dissolve and emulsify OIL RESIDUE stain completely which is resulting stain-free surface, Then without flushing with water follow 1st step.

Images: Alt



RXSOL PCS

Size:

Color:

Product Short Description: Innovative, concentrated liquid product specifically engineered to attack, penetrate and remove Coal Carbon, pet coke, lime deposition
Product Technical Specification:

PROPERTIES

RXsol PCS (Coal Remover) is a concentrated liquid solution containing powerful surface– active agents, a corrosion
inhibitor and aqueous chemical agents.
Appearance / Color : Clear, light yellow liquid.
Specific gravity         : 1.1–1.2 gr/cm3 at 20°C
pH                              : 11.5–12.5


 

Remarks:

SAFETY AND HANDLING

HANDLING

:

Handle with care. Store in a dry, cool and well ventilated environment.

Eye Contact

:

Eye contact. Otherwise, flush with plenty of water for a few minutes. Seek medical attention.

Skin Contact

:

Skin contact. Otherwise, wash contaminated area thoroughly with water. Seek medical attention.

Inhalation

:

Do not breathe gas/vapors. Otherwise, seek fresh air source at once. Seek medical attention. In case of insufficient ventilation, wear suitable respiratory equipment.

If Swallowed

:

Ingestion. Otherwise, consume a considerable quantity of water. Do not induce vomiting. Seek medical attention.

GENERAL

INSTRUCTIONS

:

Avoid spillage, splashing and mishandling. Precautionary measures for body protection are strongly recommended before use.

Images: Alt



Car Wash Shampoo 210 Ltr

Size:

Color:

Product Short Description: A new and exciting silicon base product treated for the really tough cleaning problem faced on the proper maintenance of AUTOMOBILES. our shampoo globules keep apart by mutual repulsion and are said to have been emulsified grease globules bearing dirt can
Product Technical Specification:

 

Appearance/Odour

: Liquid Green / Yellow, Pleasant odour

pH

: 8.5

Boiling point/boiling range

: 100 ºC

Melting point

: Not applicable.

Flammability (solid, gas)

: Not classified

Explosive properties

: Not classified

Oxidising properties

: Not classified

Flash point

: Not applicable.

Relative density

: 1

Water solubility

: Complete

Evaporation rate

: No data available

 
Remarks:
Images: Alt



Xylene AR reagent

Size:

Color:

Product Short Description: Xylene analar reagent grade for oil, Scale Composition tests, metering operations.
Product Technical Specification:

XYLENE ANALAR,2.5LTR

Remarks:
Images: Alt



Diethyl Hydroxyl Amine N,N- DEHA

Size:

Color:

Product Short Description: A colourless to pale yellow transparent liquid, available as 98% DEHA and also as 85% solution in water.
Product Technical Specification:

Physical Properties

Empirical Formula   C4H11NO
Molecular Wt   89.1
  DEHA 98% DEHA 85%
Sp. Gr. at 20°C  0.855 - 0.875 0.895 - 0.905
Refractive Index 1.418 - 1.420 1.418 - 1.420
Boiling Point 124 to 126°C 94 to 96°C
Freezing Point -25 to -27°C Below 0°C
Flash Point (Closed C) Below 45°C 45 to 47°C
Solubility in water Soluble Soluble
pH 10.2 10

 Specification :

Specification DEHA 98% DEHA 85%
Purity as DEHA (wt. %) 98.00 min.   85.00 min.
Water Content (% by wt.)   -- 15.00 max
Ethylamines (% by wt.) 0.5 max. 0.05 max.
Remarks:

Diethylhydroxylamine (DEHA) is an organic compound with the formula (C2H5)2NOH. It is a colorless liquid, although it is usually encountered as a solution. It is mainly used as an oxygen scavenger in water treatment. It is a volatile oxygen scavenger and reacts in a ratio of 2.8/1 DEHA/O2. It is employed in high pressure (>70 bar) boiler systems due to a very low rate of reaction at low temperatures and pressures. Due to its volatility, it acts as an oxygen scavenger throughout the entire boiler system due to steam carryover. DEHA also reacts with ferrous metals to form a passivized film of magnetite throughout the boiler system.

Images: Alt



Sodium Hypo Chlorite 20%

Size:

Color:

Product Short Description: High-test hypochlorite (HTH) is sold for chlorination of WATER
Product Technical Specification:

12.5% wt. SODIUM HYPOCHLORITE - EXTRA - PURE

Parameters Specification Range Typical

Sodium Hypochlorite

as NaOCl (%wt)

12.5 - 13.2 13.0
Available Chlorine (%wt) 11.9 - 12.6 12.4
Available Chlorine (%vol) 14.3 - 15.3 15.0
Available Chlorine grams/liter 143 - 153 150
Excess Caustic (%wt) 0.25 - 0.80 0.30
Specific Gravity @ 60°F 1.197 - 1.220 1.210
pH 12.0 - 13.0 12.50
Iron (Fe) ppm <0.5 0.05
Nickel (Ni) ppm <0.2 0.02
Copper (Cu) ppm <0.2 0.05
Mercury (Hg) ppb 0.001 - 0.003 0.002
Sodium Chloride (NaCl)% <15.0 12.5

Appearance: Clear greenish-yellow liquid miscible in any proportion with water.
This product meets the requirements of NSF standard 60 for drinking water.

Remarks:

Sodium Hypo Chlorite

Electrolysis Process ( Pure & Concentrated )
This is an improved version of this method, known as the Hooker process, In the process, sodium hypochlorite (NaClO) formed when chlorine is passed into cold and dilute sodium salt solution. It is prepared with minimal separation between the anode and the cathode .The solution must be kept below 40 °C (by cooling coils) to prevent the undesired formation of sodium chlorate and to keep chlorine concentration up to 15%.

Chloro Alkali process ( Chlorine value is less )

E. S. Smith patented a method of sodium hypochlorite production involving electrolysis of brine to produce sodium hydroxide and chlorine gas, which then mixed to form sodium hypochlorite. This is known as the chloralkali process. Both electric power and brine solution were in cheap supply at the time, and various enterprising marketers took advantage of the situation to satisfy the market's demand for sodium hypochlorite. Bottled solutions of sodium hypochlorite were sold under numerous trade names.

Bye Products

This is bye products of HEAVY / Metal industries. During treatment of main products, huge quantities of SOD. HYPO Chlorite produce, with mixture of many unwanted toxic impurities . This is completely waste of the plant , but sold by traders to satisfy market demands.

Images: Alt



Carburising Fluid Rx

Size:

Color:

Product Short Description: Gas carburising fluid is basically pit-pot type fluid used for hardening / case carburising / carbonitriding of various components made of steel such as railway part, auto parts, gears, precision turned components, construction machinery parts and any oth
Product Technical Specification:

PHYSICAL & CHEMICAL PROPERTIE

 

Colour & Appearance     

: Yellow liquid

Sp. Gravity @ 30°C

: 0.81

pH (neat)

: 8.00

Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Lime Remover HD 25 Ltrs

Size:

Color:

Product Short Description: LIME REMOVER HD is an innovative, concentrated liquid product specifically engineered to attack, penetrate and remove lime deposit accumulations from cargo and storage tanks. It is liquid product designed to Clean and eliminate limestone caustic lime de
Product Technical Specification:

Lime Remover HD is a concentrated aqueous solution consisting of a blend of special surfactants and specific corrosion inhibitors.

Appearance / Color   : Clear  liquid

Specific gravity         : 1.10–1.20 at 15°C

Solubility in water     : 100% Soluble

Boiling Point             : 100 °C

Remarks:

Lime Remover HD  is formulated with strong Surfactant agents and special corrosion inhibitors, sufficient enough to neutralize strong alkaline nature of LIME.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



HBI CARGO Hold Wash Concentrate RX 25 Ltrs

Size:

Color:

Product Short Description: HBI CARGO Hold Wash Concentrate RX is a versatile all-purpose QUALITY marine cleaning solution. It can be used as a powerful stand-alone cleaner for HBI CARGO . it can be used as a powerful\ stand alone cleaner for HBI CARGO dust and deposition .
Product Technical Specification:
Remarks:

HBI at Elevated Temperatures
The Master of the ship must notify the port authorities if hydrogen gas is detected in the ship holds or if abnormal temperatures are measured in the HBI cargo holds. The Harbor Master and qualified personnel are responsible for executing the action plan when a ship or barge arrives with HBI at the following temperature levels:

A. Greater Than 65° Celsius but Less Than or Equal to 80° Celsius
Proceed with the following actions:

1 > Before unloading the vessel, measure the HBI temperature in each hold and record the measurements in the temperature log book.
2 >  Unload the holds in the assigned zone and immediately transfer the HBI to the storage yard zone as described in PART II, Section 5.4 of this guide.

B. Temperature Greater Than 80° Celsius and Less Than or Equal to 150°
Celsius

Proceed with the following actions:
1 > Before unloading the vessel, measure the HBI temperature in each hold and record the measurements in the temperature log book. This should be done every two hours while the contingency is in effect.
2 >  Unload the holds with HBI at temperature less than 65º Celsius first, then those containing HBI between 65º and 100º Celsius. Continue unloading HBI with temperatures between 100º and 150º Celsius in the
first transfer station, using the movement sense of the belt as a
reference.
3 >  Transfer the HBI from the unloading zone clean and free of debris and flammable material, such as coal, coke and wood to the storage yard indicated by the client as follows:
Transfer the HBI during a maximum of three-minute intervals, and dose (i.e., mix the hotter with the cooler material to have an average temperature lower than the hottest one – no water to be used) the HBI that is at temperatures between 100° and 150° Celsius with cooler material for a maximum of two minutes. Stop the vibrating feeders for about five minutes, but keep the conveyor belts in motion. Repeat these steps until finished with HBI removal. While transferring the HBI, inspect the belt transfer system for any sign of overheating. In case of belt overheating, stop the HBI dosing and transfer but keep the transfer belts in motion until they cool. Take special care to avoid pouring water into hoppers and other equipment. Use a front-end loader to spread the HBI to a level of approximate 30 centimeter height to stop the reoxidation,  Verify that the belts are cooled down and resume HBI transfer per
the previous instructions.


C . Greater than 150° Celsius
Proceed with the following actions:
1 > Before unloading the holds, measure the HBI temperature in each hold and record the measurements in the temperature log book. This should be done every two hours while the contingency is in effect.
2 > Position the HBI with temperatures greater than 150° Celsius at the end of the reception area and spray with pressurized water. In this case, there is no option but to momentarily cool down the HBI.
3 >  When the temperature is reduced to between 80º and 150° Celsius proceed with the steps described in 6.3.2.2. Caution: Do not spray water on hot HBI that is steaming (i.e., emitting water vapor). 

Procedure If Hydrogen Concentration Is Over 1% (25% LEL)
1 > Inform the shipper immediately and seek expert advice.
2 > Keep the natural surface ventilation open at all times
3 > Monitor LEL in the holds continuously until level drops to less than 25 %.
4 > Avoid any possible ignition source on the vicinity.
5 > Care shall be taken as to prevent any spark generation.
6 > Monitor the hydrogen concentration in the holds and keep the surface ventilation (either natural or mechanical) until values fall below 1%.
7 > When hydrogen levels are within safe values, proceed as normal.
8 > On the contrary, additional ventilation should be applied to the space if available and re-testing should be conducted after a suitable interval.
9 > Contact the P & I Club and Shipper and follow the instructions of the appointed expert or surveyor.
10 > At sea, do not open the troubled hold without explicit instructions from the shipper or appointed expert or surveyor.
11 > Ensure there are no possible sources of ignition near the cargo spaces, adjacent spaces or open decks.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



NITRIC ACID 68 % 50 Kg

Size:

Color:

Product Short Description: Extra pure NITRIC , removes iron residue & forms an oxide layer that boosts the corrosion resistance of the stainless steel intended to improve the corrosion resistance
Product Technical Specification:
Remarks:

Nitric Acid (68%) Safety Data Sheet

 

Chemical Identity

Chemical Name

Nitric Acid

Chemical Classification

Inorganic Acid

Formula

HNO3

CAS Number

7697-37-2

UN Number

2031

Shipping Name

Nitric Acid

Codes / Label

Corrosive, Oxidiser, Class 8

Hazardous waste ID No.

16

Hazchem Code

2 PE

 

 

 

 

Physical / Chemical Data

Boiling Point / Range

120 Deg. C

Melting / freezing Point

- 40 Deg. C

PhysicalState

Watery Liquid

Specific Gravity

1.40

Solubility in water

Soluble

PH

Acidic

Appearance

Colourless to Brown

Odour

Choking Odour

 

 

 

Fire / Explosion Hazard Data

Flammability

No

LEL / UEL

Not Pertinent

Flash Point

Not Pertinent

Autoignition Temperature

Not Pertinent

Explosion Sensitivity to Impact

Stable

Explosion Sensitivity to Static Electricity

Stable

Hazardous Combustion Products

May emit poisonous oxides of
Nitrogen and Acid fumes

Oxidiser

Yes

Corrosive Material

Yes

Combustible / Flammable / Explosive Material

No

 

 

Health Hazards / First Aid Measures
Seek Medical help immediately in case of ingestion / inhalation / contact with skin. In the meanwhile following actions are recommended.

Inhalation

Remove the victim to fresh air area. Provide artificial respiration if required.

Ingestion

Give large quantities of water. Do not induce vomiting.

Contact with skin

Flush the affected area with plenty of water for long time.

 

 

 

 

Preventive Measures
Avoid contact with liquid or vapours. Provide air mask, rubber acid suit, hood, boots, gloves, safety goggles, face shield to the workmen. Water shower and eye wash basin should be provided near the workplace.

Spills
Dilute with water and neutralise with alkali.

 

Images: Alt
stock-clearance.png