Stainless Steel Cleaner

Size:

Color:

Product Short Description: RXSOL STAINLESS STEEL CLEANER contains no silicones or abrasives; will not cause spotting or streaking; and resists fingerprints. leaves a high gloss, fingerprint resistant, protective shine, on all solvent resistant surfaces. Quickly removes tarnish and food stains.
Product Technical Specification:
Remarks:
Images: Alt



CHEMZOL 9330

Size:

Color:

Product Short Description: Scale and Corrosion Inhibitor for closed loop systems without presence of any heavy metals
Product Technical Specification:
Parameter Value
Appearance Clear, pale amber liquid
Odor Mild, characteristic
pH (as supplied) Acidic
Specific Gravity @ 25°C 1.12 – 1.18
Solubility 100% water soluble
Biodegradability >90% (readily biodegradable)
Remarks:
Images: Alt



CHEMZOL 941

Size:

Color:

Product Short Description: Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.
Product Technical Specification:
Parameter Result
Appearance Paly Yellow, Clear liquid
Density 1.01-1.1
Boiling Poitnt  100 degree celcius
Remarks:

Frequently Asked Questions about Boiler treatment

Q1. What is a corrosion scale inhibitor and why is it important for boilers?

Answer:

A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.

Q2 How do I choose the right scale inhibitor for my boiler?

Answer:

Choosing the right inhibitor depends on:

  • Boiler pressure and temperature

  • Feedwater quality (e.g., hardness, pH, oxygen content)

  • Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)

Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).

Q3 How often should I dose my boiler with a corrosion scale inhibitor?

Answer:

The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Images: Alt



CHEMZOL 9200

Size:

Color:

Product Short Description: Extremely suitable oxygen scavenger for low and medium pressure boilers.
Product Technical Specification:

 

Solubility (10 % Aquous Soln)  V. S. Hazy to clear solution.
pH Value of 5% Solution 3.5 to 4.5
Specific Gravity @ 25° C  1.310 – 1.370
Density, lbs/gal @ 25° C 10.9 - 11.3
Description Oxygen Scavenger for Boiler
Standard Packing 30 Kg / 50 Kg. / 250 kg HM HDPE Barrel
Remarks:

The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.

Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.

The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.

The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation

It is used to arrest oxygen in sea water

It removes Entrapped Oxygen and thus reduces Corrosion

In Oil Drilling Chemicals

Images: Alt



Tri Ethylene Glycol

Size:

Color:

Product Short Description: High-purity specifications viscous liquid. Big drum sealed packing to maintain its quality to meet
Product Technical Specification:

Physical Properties:

Melting Point   −7 °C(lit.)
Boiling Point  125-127 °C0.1 mm Hg(lit.)
Density 1.124 g/mL at 20 °C(lit.)
Vapour density 5.2 (vs air)
Vapour pressure  <0.01 mm Hg ( 20 °C)
Refractive index  n20/D 1.455(lit.)
Flash Point  165 °C
Storage temprature  Store below +30°C.
Solublity H2O: 50 mg/mL at 20 °C, clear, colorless
Form Viscous liquid 
pKa 14.06±0.10(Predicted)
Colour Clear very slight yellow
PH 5.5-7.0 (25℃, 50mg/mL in H2O)
Odour  Very mild sweet 
Explosive limit  0.9-9.2%(V)
Water solublity  Soluble
Sensitive  Hygroscopic
Dielectric constant 2.4(25℃)
Stability Stable combustible incompatible with strong oxidizing agent

 

H2O: 50 mg/mL at 20 °C, clear, colorless
Remarks:
Images: Alt



Diphenyl Phthalate

Size:

Color:

Product Short Description: Is the diphenyl ester of benzene 1 2 dicarboxylic acid
Product Technical Specification:
PHYSICAL PROPERTIES
Appearance White Powder to Crystal
Purity(GC) min. 98.0 %
Melting point 72.0 to 76.0 °C
Solubility in Hot Methanol Almost transparency
Remarks:

Chemical properties: Diphenyl phthalate has the following chemical and physical properties:

  • Exact mass: 318.08920892 g/mol
  • Hydrogen bond donor count: 0
  • Hydrogen bond acceptor count: 4
  • Rotatable bond count: 6
  • Topological polar surface area: 52.6Ų
  • Heavy atom count: 24 
Images: Alt



Sodium Hydrosulfide Hydrate

Size:

Color:

Product Short Description: Sodium Hydrosulfide Hydrate is a moderately water and acid soluble Sodium source for uses compatible with sulfates.
Product Technical Specification:

Properties :

Compound Formula              H3NaOS
Molecular Weight  74.08
Appearance White crystals or chunks  
Melting Point 52-54 °C
Boiling Point N/A
Remarks:
Hydrogen Sulfide is used in several industries and is a by-product of many industrial processes including oil refining, mining, tanning, wood pulp processing, food processing, craft paper production, and rayon manufacturing.
Images: Alt



Sodium Hydrosulfide Hydrate

Size:

Color:

Product Short Description: Is a moderately water and acid soluble Sodium source for uses compatible with sulfates
Product Technical Specification:

Properties :

Compound Formula              H3NaOS
Molecular Weight  74.08
Appearance White crystals or chunks  
Melting Point 52-54 °C
Boiling Point N/A
Remarks:
Images: Alt



DI OCTYL PHTHALATE

Size:

Color:

Product Short Description: Dioctyl Phthalate DOP is a colourless clear liquid.
Product Technical Specification:
PRODUCT NAME   : DIOCTYLPHTHALATE
CAS number : 117-81-7
UN number  :  
Formula : C6H4(COOC8H17)2
Odour   : MILD
Solubility in water  : INSOLUBLE
Density   : 0.986   at 20 oC
Boiling point  : 386 oC
Melting point    :  -55oC
Viscosity         :  
Flashpoint    : 199oC
Explosive limits  : 0.3 – 2.4 Vol%
Vapour pressure : -10 mbarat 20oC
Skin absorption/irritation      : YES
TLV       Country  NL             Year   1995    : ppm                 5          mg/m3
Pollution category       :  III
 
Remarks:

RXSOL provide wide range of Chemicals such as Detergent Chemical, Agricultural Chemical, Industrial Chemical, Plastic Chemical and many more. We are serving in the industry from a long time period and offering our qualitative product to our renowned customers with the view to satisfying their need by the extreme quality product. They are highly appreciated in the market best of using best quality raw material while manufacturing.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



DI OCTYL PHTHALATE

Size:

Color:

Product Short Description: Dioctyl Phthalate DOP is a colourless clear liquid. Dioctyl Phthalate is one of the most widely used plasticizers
Product Technical Specification:
PRODUCT NAME   : DIOCTYLPHTHALATE
CAS number : 117-81-7
UN number  :  
Formula : C6H4(COOC8H17)2
Odour   : MILD
Solubility in water  : INSOLUBLE
Density   : 0.986   at 20 oC
Boiling point  : 386 oC
Melting point    :  -55oC
Viscosity         :  
Flashpoint    : 199oC
Explosive limits  : 0.3 – 2.4 Vol%
Vapour pressure : -10 mbarat 20oC
Skin absorption/irritation      : YES
TLV       Country  NL             Year   1995    : ppm                 5          mg/m3
Pollution category       :  III
 
Remarks:

RXSOL provide wide range of Chemicals such as Detergent Chemical, Agricultural Chemical, Industrial Chemical, Plastic Chemical and many more. We are serving in the industry from a long time period and offering our qualitative product to our renowned customers with the view to satisfying their need by the extreme quality product. They are highly appreciated in the market best of using best quality raw material while manufacturing.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



CorroSOL 66 Corrosion Scale Inhibitor Boiler

Size:

Color:

Product Short Description: Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.
Product Technical Specification:
Appearance Paly Yellow, Clear liquid
Density 1.01-1.1
Boiling Poitnt  100 degree celcius
Remarks:

Frequently Asked Questions about Boiler treatment

Q1. What is a corrosion scale inhibitor and why is it important for boilers?

Answer:

A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.

Q2 How do I choose the right scale inhibitor for my boiler?

Answer:

Choosing the right inhibitor depends on:

  • Boiler pressure and temperature

  • Feedwater quality (e.g., hardness, pH, oxygen content)

  • Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)

Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).

Q3 How often should I dose my boiler with a corrosion scale inhibitor?

Answer:

The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



CorroSOL 30 Polymer Caustic Scale Sludge Conditioner

Size:

Color:

Product Short Description: Product to be used in situations where the boiler water is contaminated with oil. This high performance product is applicable to both medium and low-pressure steam boilers in order to prevent sludge deposits.
Product Technical Specification:

This is a white high molecular weight solution. It is hydrophilic and of low causticity.
Appearance / Color : White, viscous liquid 

pH : 8
Odor : Odorless 
Remarks:

Our others valauable Products : 
BOILER TREAT ONE SHOT

Combined Boiler Water Conditioner

A one-product treatment for all auxiliary boilers including waste heat, and exhaust gas boilers. it prevents scale formation, inhibits corrosion and conditions sludge.

HARDNESS CONTROL
Boiler Water Conditioner

Added to the boiler water to maintain optimum phosphate level, which prevents calcium and magnesium hardness salts formation. The precipitate can be removed by blow-down.

ALKALINITY CONTROL
Boiler Water Conditioner 

Added to the boiler water to maintain optimum alkalinity level to prevent corrosion. Due to this, Ca and Mg hardness salts cannot form and the precipitate is removed by blow-down.

HYDRAZIDE
Oxygen Scavenger 
Used for rapid removal of oxygen in boiler feed water and condensate systems, which prevents corrosion. It is the alternative for hazardous and potentially carcinogenic products.

BOILER TREAT COMBI
Organic Boiler Water Treatment 
Special blended low molecular weight compounds that elevate boiler water pH to levels, which reduce corrosion. It also prevents under deposit corrosion caused by excess alkalinity.

LIQUID COAGULANT
Oil and Sludge Conditioner 

Used to prevent formation of adherent deposits and sticky sludge in boilers,which are then removed by normal blow-down. It can also be used in the event of an oil contamination.

CONDENSATE CONTROL
Steam and Condensate Conditioner 

Injected into the condensate pump to prevent corrosion in steam and condensate lines.It’s also used to protect idle boilers from corrosion. It neutralizes acidic conditions in condensate systems and volatilizes with steam.

COOL WATER TREAT NCLT
Corrosion and Scale Inhibitor 
Provides an effective anodic inhibitor treatment and protects ferrous and non-ferrous metals. It deposits a microscopic protective film on surfaces and has built-in pH buffering compounds. It controls formation of hard scale deposits.

EVEPORATOR TREAT
Prevention of scale in Evaporators
Used in both high and low pressure evaporators to prevent foaming, carry-over and scale formation. It’s safe to use where distillate is used for drinking purposes. It prevents scale formation and avoids the need for acid descaling.

Images: Alt
stock-clearance.png