Buffer Cleaner
Oman Chemical is leading one Largest Supplier, Manufacture a
Product Code: RXSOL-42-1008-0025
PRODUCT PROPERTIES of Safe Acid Descalex powder
HS CODE of Safe Acid Descalex powder 34021300
| Appearance | Reddish / Yellowish / white – Powder ( without indicator ) | |
| Density | 1.2g/cm3 | |
| pH | (10 wt %):1.1 | |
| Compatibility | ||
| Metal | Avoid aluminium, zinc, tin and their alloys. Avoid galvanised surfaces | |
| Rubber | No known effect | |
| Packaging | Order No.: RXSOL-54-1008-025 | Size (in kg)25 , 5 |
- Prevent run off water from entering drains if possible
Formation of Calcium Sulfate is main cause for SCALE formation :::
The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation. Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously. There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.
In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices. The low hardness levels largely preclude calcium sulfate boiler scale. By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal. Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated. Calcium sulfate scale deposition can result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals. Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger.
Sulfate content can be calculated in Laboratory by using this method ::: http://rxmarine.com/SULFATE-TEST-KIT

Product Code: RXSOL-42-1308-030
|
Chemical Name |
Percent |
Value |
Test Method |
|
Sodium hydroxide(NaOH),min. |
% |
48-55 |
STAS3068 |
|
Sodium carbonate (Na2CO3), max |
% |
0.7 |
STAS3068 |
|
Water |
% |
45-52 |
|
Appearance: Liquid, clear to slight haze, colorless to light grey tint.
Odor: No odor
pH: 14 as is basis
Melting/Freeze point-range: -18⁰C - -12.8⁰C (0⁰F-5⁰F) approx.
Boiling point-range: 110⁰C-113⁰C (230⁰F- 236⁰F) approx.
Flash point: NA
Evaporation rate: NA
Flammability: Not flammable.
Upper/lower flammability limits: NA
Vapor pressure: NA
Vapor density: NA Relative
Water Solubility: Complete.
Partial coefficient: n-octanol/water: NA
Auto ignition: NA
Decomposition temperature: NA
Viscosity: 7-10 cps @ 20⁰C (68⁰F)

Product Code: RXSOL-42-4049-025

Product Code: RXSOL-42-5040-210

Product Code: RXSOL-42-6001-025
| CharactersItics | Properties | |
| Appearance Thermal Firmness | Clear yellow liquid 250° C | By keeping heat transfer surfaces free of scale, Ensures that the evaporator works at maximum efficiency. |
| Density | In g/cm3 at 15°C: 1.1 |
Permits more efficient evaporation. |
| pH (1 Vol%) | 9 |
Reduces downtime and maintenance costs. |
| Compatibility | Concentrated, safe liquid, easy and economical dosing. | |
| Metal | No known effect |
For use in both high pressure and vacuum evaporators |
| Rubber | No known effect | The antifoaming properties ensure that distillate quality is high |
| Packaging |
20 / 25 ltr |
Improves the quality of distilled water |
RXSOL-51-6001-025 is a concentrated solution of a POLYELECTROLYTE polymer and Antifoaming Agents for use in SEA WATER evaporator as a controller of scale and foam in side the evaporators. It can be used as a scale inhibitor in the feed water to EVAPORATORS producing fresh water .
A liquid polymer-based evaporator treatment specially designed to control and prevent scale formation in evaporators

Product Code: RXSOL-42-2541-210
Physical properties :::
Carbohydrazide the Hydrazide of carbonic acid
| Molecular formula: | OC(N₂H₃)₂ |
| CAS No.: | |
| Molecular weight: | 90.09 |
| Description: | White Solid |
| odor: | Characteristic Smell |
| Density: | 1.34 (25/4°C) |
| Solubility: | Soluble in Water, Ethanol |
| vapor density: | 1.04 (air = 1) |
| vapor pressure: |
14.4 mm Hg at 25°C |
Carbohydrazide is used as an oxygen scavenger for high pressure boilers in power plants and other industries to reduce corrosion of metal pipes and fittings.
What is CarboHydrazide ?
Carbohydrazide the hydrazide of carbonic acid.
Why Hydrazine is replace by Carbohydrazide ?
Carbohydrazide (CH6N4O) - RXSOL-42-2541-025 is an oxygen scavenger often added to boiler systems to control corrosion. It reacts with oxygen at low temperatures and pressures. It also passivates metal surfaces preventing further corrosion. The reaction products are volatile, so they do not contribute to dissolved solids in the system. Carbohydrazide is widely used to replace hydrazine as an oxygen scavenger because it is less toxic.

Product Code: RXSOL-42-5015-005
It is very Powerful Aluminium Cleaner
| Appearence | liquid |
| Colour | light red |
| Odour | mild |
| Melting point: | not applicable |
| Flash point | not applicable |
| Spontaneous ignition |
not applicable, no Danger of explosion |
This product is avilable with all our associated ship chandlers of INDIA and Middle East by product code no RXSOL-16-1028-025.
we are manufactrer of RXSOL-16-1028-025 , and supplier in kakinada, Visakhapatnam, Vizag, Mumbai, Goa, Surat, Gandhidham, Kandla, Mundra, Chennai, Ennore, Kolkata, Haldia, Pirpav, Fujairah, Dubai, Sharjah, Abu Dhabi and Gulf.
RXSOL brand Aluminium Cleaner exporter for TURKEY, Australia.

Product Code: RXSOL-42-4029-035
| Property | Value |
|---|---|
| Appearance | Clear to slightly hazy amber liquid |
| Odor | Mild characteristic |
| pH (as supplied) | Alkaline |
| Specific Gravity @ 25°C | 1.10 – 1.20 |
| Solubility | Fully water soluble |
| Freeze Point | Below 0°C |
| Shelf Life | 12 months (sealed container) |

Product Code: RXSOL-42-4029-050
| Parameter | Result |
|---|---|
| Appearance | Paly Yellow, Clear liquid |
| Density | 1.01-1.1 |
| Boiling Poitnt | 100 degree celcius |
Frequently Asked Questions about Boiler treatment
Answer:
A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.
Answer:
Choosing the right inhibitor depends on:
Boiler pressure and temperature
Feedwater quality (e.g., hardness, pH, oxygen content)
Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)
Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).
Answer:
The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Product Code: RXSOL-42-1524-050
| Solubility (10 % Aquous Soln) | V. S. Hazy to clear solution. |
| pH Value of 5% Solution | 3.5 to 4.5 |
| Specific Gravity @ 25° C | 1.310 – 1.370 |
| Density, lbs/gal @ 25° C | 10.9 - 11.3 |
| Description | Oxygen Scavenger for Boiler |
| Standard Packing | 30 Kg / 50 Kg. / 250 kg HM HDPE Barrel |
The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.
Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.
The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.
The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation
It is used to arrest oxygen in sea water
It removes Entrapped Oxygen and thus reduces Corrosion
In Oil Drilling Chemicals