CHEMZOL 941

Size:

Color:

Product Short Description: Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.
Product Technical Specification:
Parameter Result
Appearance Paly Yellow, Clear liquid
Density 1.01-1.1
Boiling Poitnt  100 degree celcius
Remarks:

Frequently Asked Questions about Boiler treatment

Q1. What is a corrosion scale inhibitor and why is it important for boilers?

Answer:

A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.

Q2 How do I choose the right scale inhibitor for my boiler?

Answer:

Choosing the right inhibitor depends on:

  • Boiler pressure and temperature

  • Feedwater quality (e.g., hardness, pH, oxygen content)

  • Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)

Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).

Q3 How often should I dose my boiler with a corrosion scale inhibitor?

Answer:

The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Images: Alt



CHEMZOL 9200

Size:

Color:

Product Short Description: Extremely suitable oxygen scavenger for low and medium pressure boilers.
Product Technical Specification:

 

Solubility (10 % Aquous Soln)  V. S. Hazy to clear solution.
pH Value of 5% Solution 3.5 to 4.5
Specific Gravity @ 25° C  1.310 – 1.370
Density, lbs/gal @ 25° C 10.9 - 11.3
Description Oxygen Scavenger for Boiler
Standard Packing 30 Kg / 50 Kg. / 250 kg HM HDPE Barrel
Remarks:

The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.

Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.

The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.

The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation

It is used to arrest oxygen in sea water

It removes Entrapped Oxygen and thus reduces Corrosion

In Oil Drilling Chemicals

Images: Alt



CorroSOL 66 Corrosion Scale Inhibitor Boiler

Size:

Color:

Product Short Description: Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.
Product Technical Specification:
Appearance Paly Yellow, Clear liquid
Density 1.01-1.1
Boiling Poitnt  100 degree celcius
Remarks:

Frequently Asked Questions about Boiler treatment

Q1. What is a corrosion scale inhibitor and why is it important for boilers?

Answer:

A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.

Q2 How do I choose the right scale inhibitor for my boiler?

Answer:

Choosing the right inhibitor depends on:

  • Boiler pressure and temperature

  • Feedwater quality (e.g., hardness, pH, oxygen content)

  • Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)

Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).

Q3 How often should I dose my boiler with a corrosion scale inhibitor?

Answer:

The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



CorroSOL 30 Polymer Caustic Scale Sludge Conditioner

Size:

Color:

Product Short Description: Product to be used in situations where the boiler water is contaminated with oil. This high performance product is applicable to both medium and low-pressure steam boilers in order to prevent sludge deposits.
Product Technical Specification:

This is a white high molecular weight solution. It is hydrophilic and of low causticity.
Appearance / Color : White, viscous liquid 

pH : 8
Odor : Odorless 
Remarks:

Our others valauable Products : 
BOILER TREAT ONE SHOT

Combined Boiler Water Conditioner

A one-product treatment for all auxiliary boilers including waste heat, and exhaust gas boilers. it prevents scale formation, inhibits corrosion and conditions sludge.

HARDNESS CONTROL
Boiler Water Conditioner

Added to the boiler water to maintain optimum phosphate level, which prevents calcium and magnesium hardness salts formation. The precipitate can be removed by blow-down.

ALKALINITY CONTROL
Boiler Water Conditioner 

Added to the boiler water to maintain optimum alkalinity level to prevent corrosion. Due to this, Ca and Mg hardness salts cannot form and the precipitate is removed by blow-down.

HYDRAZIDE
Oxygen Scavenger 
Used for rapid removal of oxygen in boiler feed water and condensate systems, which prevents corrosion. It is the alternative for hazardous and potentially carcinogenic products.

BOILER TREAT COMBI
Organic Boiler Water Treatment 
Special blended low molecular weight compounds that elevate boiler water pH to levels, which reduce corrosion. It also prevents under deposit corrosion caused by excess alkalinity.

LIQUID COAGULANT
Oil and Sludge Conditioner 

Used to prevent formation of adherent deposits and sticky sludge in boilers,which are then removed by normal blow-down. It can also be used in the event of an oil contamination.

CONDENSATE CONTROL
Steam and Condensate Conditioner 

Injected into the condensate pump to prevent corrosion in steam and condensate lines.It’s also used to protect idle boilers from corrosion. It neutralizes acidic conditions in condensate systems and volatilizes with steam.

COOL WATER TREAT NCLT
Corrosion and Scale Inhibitor 
Provides an effective anodic inhibitor treatment and protects ferrous and non-ferrous metals. It deposits a microscopic protective film on surfaces and has built-in pH buffering compounds. It controls formation of hard scale deposits.

EVEPORATOR TREAT
Prevention of scale in Evaporators
Used in both high and low pressure evaporators to prevent foaming, carry-over and scale formation. It’s safe to use where distillate is used for drinking purposes. It prevents scale formation and avoids the need for acid descaling.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



CorroSOL 26 Neutralised Sulphite

Size:

Color:

Product Short Description: Extremely suitable oxygen scavenger for low and medium pressure boilers.
Product Technical Specification:

 

Solubility (10 % Aquous Soln)  V. S. Hazy to clear solution.
pH Value of 5% Solution 3.5 to 4.5
Specific Gravity @ 25° C  1.310 – 1.370
Density, lbs/gal @ 25° C 10.9 - 11.3
Description Oxygen Scavenger for Boiler
Standard Packing 30 Kg / 50 Kg. / 250 kg HM HDPE Barrel
Remarks:

The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.

Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.

The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.

The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation

It is used to arrest oxygen in sea water

It removes Entrapped Oxygen and thus reduces Corrosion

In Oil Drilling Chemicals

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



CorroSOL 50 Molybdate Corrosion Inhibitor

Size:

Color:

Product Short Description: Molybdate and phosphonate based corrosion inhibitor for cooling water system to protect steel, cast iron, copper, brass, aluminium and galvanised steel.
Product Technical Specification:

Molybdate-Phosphate for Closed Circulation Machinery Cooling Corrosion inhibitor.

Appearance

Clear Colourless to Pale Liquid

Boiling point [oC]

100

C Density [kg/m3]

1.12 - 1.20

Flashpoint[oC] TCC

NONE Vapour pressure [mm Hg]

Pour point [oC]

NONE Vapour density [a ir=1]:

Auto-ignition temp [oC] NONE 
Expl.omr. [vol%] Solubility in water [w-%]: 100%
pH : Slight Alkaline
Solubility  100% in Distilled water
Rel. evaporation Rate. N/A
Recommend Dosage  ppm LEVEL 400 to 1000 ppm
Soluble in organic solvent: None
Remarks:

Use proper chemical protective hand gloves and Eye Goggles.

CorroSOL 50 Molybdate Corrosion Inhibitor closed cooling systems Molybdate Phosphonate is very effective in high hardness, highly alkaline scaling waters. It contains a proprietary blend of organic and polymeric sequestrants, penetrants and dispersants to minimize system fouling from contaminants such as calcium, silica, iron, sludge and organics. It also contains a unique blend of organic and actives to corrosion sites. Corrosion inhibitor closed cooling systems Molybdate Phosphonate is very effective also in low hardness, low alkalinity corrosive waters. It contains special filming ingredients to establish protective barriers against corrosion on ferrous metal surfaces. It also contains special filming ingredients to establish a protective barrier against corrosion and pitting on both yellow metal and ferrous metal surfaces.

Corrosion inhibitor closed cooling systems Molybdate Phosphonate is environmentally safe for discharge with the cooling system bleedoff. The formulation contains no heavy metals, chromates, or other pollutants requiring removal or treatment prior to discharge at normal usage rates.

Molybdate does not provide a nutrient source as do many other corrosion inhibitors. This eliminates a food source for algae and bacteria in the water system and makes control of microorganisms easier at lower microbiocide dosage rates. Corrosion inhibitor closed cooling systems Molybdate Phosphonate may be used alone as a single product for control of corrosion in systems where hardness and alkalinity does not pose a scaling problem, or in high hardness and/or high alkalinity waters where higher cycles of concentration and lower bleed rates are desired. Corrosion inhibitor closed cooling systems Molybdate Phosphonate offers superior corrosion protection for all metals typically found in cooling water systems. The blend of cathodic and anodic inhibitors provides a durable corrosion inhibitive film for maximum system protection and minimal corrosion rates.

Synergised Molybdate Corrosion Inhibitor

Cost effective
Non-toxic and easy to use
Excellent protection
Protects steel, cast iron, copper, brass, aluminium and galvanised steel
Can be used in systems with aluminium
Suitable for chilled water, LTHW and MTHW systems
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



CorroSOL 40 Nitrite Corrosion Inhibitor

Size:

Color:

Product Short Description: Nitrite based corrosion inhibitor for excellent protection for chilled water, LTHW systems
Product Technical Specification:

Appearance

Colourless 

Odour

Odourless 

pH

11-12 approx

Boiling Point / Boiling Range

Not determined

Melting Point/Melting Range

N/A

Flash Point N/A
Flammability Non flammable
Autoflammability N/A
Explosive Properties N/A
Oxidising Properties N/A
Vapour Pressure Not determined
Relative Density 1.18 approx
Solubility in water  Miscible
Solubility in other solvents  Not determined
Partition coefficient and N-octanol/water  ----------
Other Data None
 
Remarks:
TREATMENT                         Feature
Sodium Nitrate                       Iron and Steel corrosion inhibitor. 800-2500 ppm recommended.
Molybdate                              Slows the growth of bacteria.
Tolyltriazole                            Copper corrosion Inhibitor.
Synthetic polymer                  Prevents hard scale built up.
Borax buffer                           Corrects the water pH (Maintain pH level between 8.5 to 9.2).
Silicates                             A common corrosion inhibitor used by automotive antifreeze suppliers is silicates. Silicates have the disadvantage of building up an insulating layer on components and are not recommended for industrial engines. Concentration should not exceed 25 ppm.
 
Traditional nitrite based inhibitor
Cost effective
Excellent protection
Protects steel, cast iron, copper & brass
Not recommended for aluminium
Suitable for chilled water, LTHW systems
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



LIQUIVAP TREAT

Size:

Color:

Product Short Description: Evaporator Treatment Chemicals
Product Technical Specification:
CharactersItics   Properties
Appearance Thermal Firmness Clear  yellow liquid 250° C            By keeping heat transfer surfaces free of scale, Ensures that the evaporator works at maximum efficiency.
Density In g/cm3 at 15°C: 1.1

Permits more efficient evaporation.

pH (1 Vol%) 9

Reduces downtime and maintenance costs.

Compatibility   Concentrated, safe liquid, easy and economical dosing.
Metal No known effect

For use in both high pressure and vacuum evaporators

Rubber No known effect The antifoaming properties ensure that distillate quality is high
Packaging

20 / 25 ltr

Improves the quality of distilled water

Remarks:

RXSOL-51-6001-025 is a concentrated  solution of a POLYELECTROLYTE  polymer and Antifoaming Agents for  use in SEA WATER evaporator  as a controller of scale and foam in side the  evaporators.  It can be used as a scale inhibitor  in the  feed water  to EVAPORATORS producing fresh water .

A liquid polymer-based evaporator treatment specially designed to control and prevent scale formation in evaporators

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



AMERZAMINE

Size:

Color:

Product Short Description: 100 percent water soluble and 100 percent Volatile corrosion inhibitor for Low Medium High Pressure Boiler Water System.
Product Technical Specification:

We carry a complete line of condensate treatment chemicals.  Condensate treatment chemicals are used to increase the condensate pH, thus reducing corrosion to the entire boiler steam system.  The most common product is a tri-blend amine of cyclohexylamine, morpholine, and diethylaminoethanol (DEAE) neutralizing amines, although we do have standard RXSOL products or we can custom blend to your needs.
RXSOL-50-5005-DCM1          10% DEAE, 10% Cyclo, 10% Morpholine   
RXSOL-50-5005-DCM2          20% DEAE, 20% Cyclo, 20% Morpholine   
RXSOL-50-5005-C                  20% Cyclohexylamine    
RXSOL-50-5005-D                  20% DEAE    
RXSOL-50-5005-M                  20% Morpholine   
RXSOL-50-5005-C5                50% Cyclohexylamine    
RXSOL-50-5005-D                  50% DEAE  
RXSOL-50-5005-M5                50% Morpholine    
  

PRODUCT INTRODUCTION
Pure anisole or methoxybenzene, is an organic compound. CAS NO: 100-66-3
HANDLING & STORAGE
Keep away from heat and sources of ignition.
Store in a sealed condition at ambient temperature or below. Keep containers in tightly closed condition.
Use proper PPE during handling.
PRODUCT APPLICATION
Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.
PROPERTIES
Appearance
Clear Colorless Liquid
Purity ( by GC ) , %
99.8 Min
Specific Gravity @25°C
0.9995 ± 0.05
Moisture (by KF) , %
0.3 Max
PACKAGING
Packed in drums or in ISO TANKS on request.
Remarks:

Corrosion Inhibitor for Boiler Neutralizer alkaline and the vapors are irritating to eyes and lungs. Avoid contact with eyes and skin. Do not take internally. Observe safety regulations wear Goggles, PVC gloves and Apron when handling Provide ample ventilation Avoid contact with skin in case of contacts wash with cupious amount of water immediately. If eyes are splashed give immediate and prolonged irrigation with clean running water and obtain medical attention.

Not for internal use :-
If swallowed do not induce vomiting give plenty of water or milk and call a doctor immediately.

Packing. GENERAL REMARKS:-Do not store  
Corrosion Inhibitor for Boiler Neutralizer  near a heating equipment.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Alkaline Corrosion Inhibitor for Boiler

Size:

Color:

Product Short Description: Caustic based alkaline corrosion inhibitor for Boiler treatment
Product Technical Specification:
Remarks:
Images: Alt
stock-clearance.png