Mark Ship Chandler:

Commissioning Cleaner

Product Code: RXSOL-25-1078-025

Size:

Color:

Product Short Description: Commissioning Cleanser is for cleaning of new boilers and cooling systems on board new buildings. It will remove scale, rust, oil and grease at the same time from the systems
Product Technical Specification:

Technical Properties

The following is a proposed specification profile for a mildly alkaline, water-based flushing and degreasing formulation. It must be validated against the actual manufactured product.

Property

Proposed Target / Description

Appearance

Clear to slightly hazy liquid

Colour

Colourless to pale yellow

Odour

Mild, characteristic

Chemical Nature

Alkaline detergent, dispersant and chelating formulation

pH at 25°C

Target 9.5–11.5

Specific Gravity at 25°C

Target 1.02–1.10

Solubility

Completely dispersible or soluble in water

Foaming

Low-foaming formulation preferred

Main Function

Degreasing, particulate dispersion and system flushing

Cleaning Method

Circulation, flushing and filtration

Suggested Working Concentration

1–3% by volume for preliminary trials

Working Temperature

25–50°C, subject to system compatibility

Cleaning Duration

Typically 4–12 hours for preliminary trials

Post-Cleaning Treatment

Rinsing and corrosion inhibitor/passivation programme

Packing

25 L, 210 L and IBC options subject to confirmation

Important: These are formulation-development targets and preliminary operating ranges, not measured RXSOL product specifications. The pH, density, dosage and operating limits must be confirmed through formulation testing and system-specific cleaning trials.

 
Odour Odourless
Appeearance Liquid Off White
Specific Vapor Density No data
Liquid Density 1.12  at 20 °C
pH 8.5-9.0
Boiling Point 100 °C at 760 mm /Hg

 

Remarks:

Cleaning Mechanism

RXSOL System Flushing & Cleaning Chemical is intended to work through a combination of cleaning mechanisms:

Degreasing: Surfactants and compatible cleaning agents help emulsify cutting oils, grease and oily fabrication residues.

Wetting and Penetration: Wetting agents improve contact between the cleaning solution and deposits on internal metal surfaces.

Dispersion: Dispersing agents help suspend fine rust particles, sludge and other removable solids in the circulating water.

Chelation: Where included in the formulation, chelating agents can assist in mobilizing certain metal-containing deposits.

Flushing Action: Circulation and filtration physically remove loosened particles, welding debris and construction contamination.

Limitation: A mildly alkaline cleaner will not reliably dissolve heavy, adherent mill scale or iron oxide. These may require a separate inhibited acid or specialized chelant-based cleaning procedure.

Recommended Concentration and Contact Time

The following ranges are proposed for initial trials with a validated, mildly alkaline flushing formulation.

Cleaning Condition

Concentration

Circulation Time

Light construction dust and residues

0.5–1.0%

2–4 hours

General pre-commissioning cleaning

1.0–2.0%

4–8 hours

Moderate oil, grease and loose rust

2.0–3.0%

6–12 hours

Heavy iron oxide or adherent mill scale

Separate treatment

Determined by deposit analysis

Concentrations are expressed as percentage by volume of the final cleaning solution.

These values are provisional development recommendations, not verified field instructions for an existing RXSOL product.

 

Recommended Circulation Cleaning Procedure

01

System inspection and preparation

Confirm system volume, piping materials, pump capacity, valve arrangement and drainage facilities. Isolate sensitive components and provide suitable temporary bypasses where required.

02

Initial water flushing

Fill with suitable clean water and carry out dynamic flushing to remove loose construction debris. Clean strainers and filters regularly.

03

Chemical preparation

Prepare the selected cleaning concentration using water of suitable quality. Introduce the cleaner through an approved dosing or circulation point.

04

Chemical circulation

Circulate the cleaning solution through all intended sections of the system. Maintain sufficient flow to reach remote branches without exceeding equipment limits. Monitor pH, temperature, appearance and filtration condition.

05

Cleaning verification

Inspect strainers and representative samples. Where practical, measure suspended solids, iron concentration and oil contamination to evaluate cleaning progress.

06

Drainage and final flushing

Collect spent solution for appropriate treatment or disposal. Flush thoroughly with clean water until residual cleaner and suspended contamination meet the agreed acceptance criteria.

07

Post-cleaning passivation

Immediately apply a compatible corrosion inhibitor or passivation treatment to exposed metal surfaces, then establish the permanent water treatment programme.

 

Post-Cleaning Passivation Procedure

After cleaning, exposed carbon steel surfaces can be particularly susceptible to flash rusting. Passivation should therefore follow promptly after the final rinse.

Recommended Approach

  1. Confirm the system is free of excessive cleaning chemical and suspended solids.

  2. Select a corrosion inhibitor compatible with the system metallurgy and operating conditions.

  3. Prepare the passivation solution using water of suitable quality.

  4. Circulate the solution to ensure contact with all wetted surfaces.

  5. Monitor pH and inhibitor residual.

  6. Establish the permanent closed-loop corrosion inhibitor concentration.

  7. Maintain circulation or an approved lay-up treatment until commissioning.

Suggested Passivation Technologies

System Material

Potential Treatment Approach

Carbon Steel

Nitrite-based or nitrite-free corrosion inhibitor

Stainless Steel

Compatible low-chloride treatment

Copper / Brass

Azole-containing corrosion inhibitor programme

Mixed Metal Systems

Multi-metal inhibitor formulation

Aluminium-Containing Systems

Specially selected inhibitor and controlled pH

A nitrite-free formulation based on suitable molybdate, organic inhibitors or other approved technologies may be considered for mixed-metal cooling systems.

Passivation concentration and duration: These must be established from the selected inhibitor's formulation, manufacturer instructions and system conditions. A universal dosage cannot be recommended.

 

Cleaning and Passivation Monitoring

Parameter

During Cleaning

After Final Flushing / Passivation

pH

Monitor chemical activity and compatibility

Maintain approved system range

Conductivity

Track solution changes

Confirm flushing and final water quality

Dissolved Iron

Evaluate oxide mobilization

Confirm acceptable residual concentration

Suspended Solids

Monitor particulate removal

Meet project cleanliness criteria

Oil and Grease

Evaluate degreasing

Confirm acceptable residual levels

Inhibitor Residual

Not applicable unless included

Maintain required treatment level

Microbiological Activity

Assess where relevant

Control through approved programme

Acceptance criteria should be agreed before cleaning and based on the system specification, water treatment programme and applicable commissioning standards.

Material Compatibility

The proposed alkaline formulation is intended for use in appropriately evaluated water systems.

Material

Consideration

Carbon Steel

Generally a target material; verify cleaning chemistry

Stainless Steel

Confirm chloride and chemical compatibility

Copper and Brass

Evaluate chelant and inhibitor effects

Aluminium

Sensitive to elevated alkalinity; special assessment required

Galvanized Steel

Can be damaged by alkaline formulations

Rubber Seals

Confirm chemical resistance

Plastic Pipes

Verify temperature and solvent compatibility

Protective Coatings

Conduct a compatibility test

Do not use a strongly alkaline formulation on aluminium or galvanized components without specific validation.

Safety and Handling

  • Read the approved Safety Data Sheet before handling.

  • Wear chemical-resistant gloves, goggles and protective clothing.

  • Avoid contact with skin and eyes.

  • Provide adequate ventilation.

  • Do not mix concentrated cleaning chemicals with acids, oxidizers or biocides.

  • Use chemical-resistant pumps, hoses and storage containers.

  • Monitor pressure, temperature and circulation conditions.

  • Prevent uncontrolled release of spent cleaning solution.

  • Follow site-specific isolation, lockout and confined-space safety procedures.

Storage and Packing

Storage: Keep in tightly closed, properly labelled containers in a cool, dry, ventilated location.

Packing Options: 25 L cans, 210 L drums and 1,000 L IBCs, subject to commercial confirmation.

Shelf Life: To be established through finished-product stability testing.

Images: Alt

Urea Solution 40 Percent

Product Code: RXSOL-25-1920-1250

Size:

Color:

Product Short Description: Liquid Urea is a crystal clear aqueous solution of urea.
Product Technical Specification:

Typical Specifications

Property Typical Value
Product Name Urea Solution 40%
Appearance Clear, colourless liquid
Urea Content 40 ± 1% w/w
Balance Water
Molecular Weight of Urea 60.06 g/mol
Specific Gravity @ 20°C Approx. 1.10–1.12
pH Typically 7.0–10.0*
Solubility Completely miscible with water
Odour Mild / essentially odourless
Physical Form Liquid

*Exact specification should be established from the actual formulation and batch COA.

Remarks:

Storage

Store in a clean, closed and compatible tank or container and protect from contamination and excessive temperature. Because concentrated urea solutions can crystallize at sufficiently low temperatures, storage and transfer conditions should be selected to keep the product fully liquid.

For emission-control applications, contamination by metals, oils, salts or other chemicals should be carefully avoided where reagent purity is critical.

Urea 40 Percent solution is used as Selective Supplement for Urea Agar Base Christensen or Urea broth Base. Bacterial decomposition of urea has been especially useful in distinguishing between members of Proteus group and other organisms.

Images: Alt

Bilge Clean

Product Code: RXSOL-25-1002-005

Size:

Color:

Product Short Description: Powerful degreaser for Industries, engine rooms and fuel cargo tanks. Also breaks the oil-in-water emulsion and destabilizes the remaining small oil droplets and agglomerates them into larger particles (flocs) that are easily collected by filtering.
Product Technical Specification:
Product Properties
Appearance ............. Clear liquid
Density ..................... In g/cm3 at 20°C: 1.1
Compatibility
Metal ......................... No known effect
Rubber ...................... No known effect
pH Flash point ........... Not Applicable
Solubility .................... 100% soluble in water
Remarks:

Avoid direct contact with hand and eye. Always use MSDS before using of this product.

Images: Alt

Disinfecting Anticeptic All purpose Cleaner

Product Code: RXSOL-25-1652-025

Size:

Color:

Product Short Description: This product is concentrate cleaner and disinfectant for efficient cleaning and sainitizing.
Product Technical Specification:
Property Typical Value
Product Name Disinfecting Antiseptic All Purpose Cleaner
Appearance Clear to slightly hazy liquid
Colour Colourless to pale coloured
Odour Mild / characteristic
pH Typically 6.5-9.0*
Specific Gravity @ 25°C Typically 0.98-1.05*
Solubility Completely soluble in water
Foam Low to moderate
Base Water-based
Flash Point Normally not applicable for aqueous formulation*
Application Spray / mop / wipe / bucket
Rinsability Good on suitable surfaces
Storage Cool, dry and ventilated area
Remarks:

Two-in-One Cleaning & Disinfection

The product is designed to provide:

CLEAN → DEGREASE → DISINFECT → DEODORIZE

For routine maintenance cleaning, the same application can provide both soil removal and antimicrobial treatment.

Where heavy contamination is present, use a separate cleaning/degreasing step before disinfection. This is particularly important where heavy organic material may remain on the surface.

Images: Alt

Electrolyte KOH Liquid 30 Percent

Product Code: RXSOL-25-1024-030

Size:

Color:

Product Short Description: Potassium Hydroxide Solution in Distilled Water suitable for Nickel Cadmium Batteries
Product Technical Specification:

Key Product Information

  • Chemical Name: Potassium Hydroxide Solution

  • Common Name: Caustic Potash

  • Chemical Formula: KOH

  • Concentration: 30% w/w

  • Physical Form: Clear, colorless liquid

  • Nature: Strongly alkaline

  • Solubility: Completely miscible with water

  • Application: Electrolyte and industrial chemical

Remarks:
Images: Alt

Corrosion Treat 3762

Product Code: RXSOL-16-3762-210

Size:

Color:

Product Short Description: Corrosion Treat 3762
Product Technical Specification:
Remarks:
Images: Alt

Degreaser Solvent Green

Product Code: RXSOL-25-1005-030

Size:

Color:

Product Short Description: Heavy Duty Degreaser, especially developed for Industrial, Marine, and Engine cleaning applications
Product Technical Specification:
Remarks:

PROEDURE OF USE:-

1st Method:-
Mix 1 part of RXSOL-10-1005-025 with 2 -10 parts of water / GAS-OIL  , For heavy oil,greasy surface use directly)Spray directly on the entire surface to be cleaned. This can be achieved by Hand spray / mechanical spray pump. Immediately after 2 -5 minute of spray the RXSOL-10-1005-025 starts its function. The Dirt, oil grease etc will loosen. 5 to 6 minutes after spraying start rinsing the system with water (High pressure recommended). Dirt and mud starts vanishing with cleaning media and water.

2nd Method:-
Application in immersion process with or without ultrasonic support, manual wipping.

3rd Method:- 
RXSOL-10-1005-025 is also used in conjunction with alkaline degreasing bath at 3-5% (v/v) concentration for better and quick degreasing action. Eithers the bath is heated to be 70c or the solution can be stirred or air agitated.

Key Features of Degreaser Heavy Duty

  • Superior Cleaning Power – Quickly dissolves and removes heavy oil, grease, wax, carbon deposits, and tough hydrocarbon residues.
  • Water Soluble in All Proportions – Easily mixes with water, allowing flexible dilution for light to heavy-duty cleaning.
  • Dual Action (Solvent + Detergent) – Solvent base penetrates and loosens stubborn residues, while surfactants disperse and emulsify them for easy rinsing.
  • Non-Corrosive – Safe on common metals such as mild steel, copper, aluminium, and also compatible with plastics.
  • Reduced Manual Effort – Cuts through thick grease layers without excessive scrubbing, saving time and labor.
  • Versatile Application – Suitable for spray, brush, soak, or circulation cleaning systems in marine, industrial, automotive, and workshop environments.
  • Residue-Free Rinsing – Emulsifies contaminants and rinses away cleanly, leaving surfaces oil-free and ready for use.
  • Safe to Handle – Non-toxic formulation ensures safer handling compared to harsh solvent-only degreasers.
  • Economical – Concentrated formula offers high coverage area and low consumption per cleaning cycle.
Images: Alt

Sea Water Scale Dissolver

Product Code: RXSOL-25-1048-020

Size:

Color:

Product Short Description: Sea Water Scale Remover Cleaner Sea Water SIDE is specialized product to dissolve water scale smoothly.
Product Technical Specification:

Procedure-of-use: The most effective descaling is accomplished by circulation.In the case of small components,the soak method in an immersion bath can be used. If the equipment to be cleaned is contaminated by oil, grease or sludge, then pre-cleaning with DEGREASER ( RXSOL OB 1005 ) is necessary. Depending on the extent of scaling, use a solution of 2.5-10% RXSOL-54-1008-025 . The solution will have a red colour which changes to orange when 85% of the acid has been neutralized , & to colourless  when the solution is totally neutralized. Whenever possible, the solution should be heated to 60°C.Neutralised  solutions can be re-activated by adding more RXSOL-54-1008-025  until the red colour reappears. 

Fields: Descaling of  Boilers, Descaling  of Diesel Engine Cooling Systems, Condenser, Pipeline collection system, Evaporators, Calorifiers, Heat Exchangers,The strength of the acid can be enhanced by adding 1part sodium chloride (common salt) to 20 parts of Descalex.If salt is not available, an acceptable alternative is to dissolve RXSOL-54-1008-025  in sea water. After use of RXSOL-54-1008-025  a  0.5% solution of Alkalinity Control in fresh  water should be used for neutralization.

Remarks:

RXSOL-54-1048-020 should not be used on Aluminium, Zinc, Tin, or any Galvanized Surfaces for which a special grade cleaner should be used. Chemical Cleaning Module RX cleansers has developed a 280 litres capacity cleaning module, primarily designed for use with chemical acid solvents for descaling boilers, calorifiers, heat exchangers & other types of equipment where rust & scale form RXSOL-11-1008--DC Boilers, See RX cleansers Practical Application Manual

 

The engine room is the heart of any vessel, responsible for the propulsion and essential power systems that keep the ship running smoothly. Proper engine room maintenance is critical to ensuring safety, efficiency, and regulatory compliance. At RXMARINE International, we specialize in providing high-quality marine chemicals that enhance maintenance procedures, keeping vessels in top condition.

Why Engine Room Maintenance Matters

  • Prevents Downtime & Costly Repairs: Regular inspections help detect early signs of wear and tear, reducing expensive breakdowns.

  • Enhances Fuel Efficiency: A well-maintained engine operates efficiently, cutting down fuel consumption and operational costs.

  • Ensures Crew Safety: Proper maintenance minimizes the risk of hazardous incidents such as fires, leaks, or mechanical failures.

  • Regulatory Compliance: Compliance with international maritime regulations (IMO, SOLAS) is essential to avoid fines and ensure smooth sailing.

Key Aspects of Engine Room Maintenance

1. Cleaning & Degreasing

The accumulation of oil, grease, and dirt can lead to overheating and reduced efficiency. Using RXMARINE’s Engine Room Cleaners & Degreasers, you can effectively remove sludge, carbon deposits, and oil residues.

2. Lubrication System Maintenance

  • Regular oil changes using high-quality marine lubricants help prevent friction and wear.

  • Monitoring oil viscosity and contamination is crucial to detect potential engine issues early.

3. Cooling System Efficiency

  • Scale and corrosion in heat exchangers and cooling lines reduce efficiency. Descaling chemicals like RXMARINE’s RXSCALE help prevent blockages and maintain optimal cooling.

  • Ensure coolant levels are checked regularly to prevent overheating.

4. Fuel System Treatment

  • Fuel contamination with water, sludge, and microbial growth can affect engine performance. Using fuel additives and biocides prevents clogging and improves combustion efficiency.

  • Regularly clean fuel injectors and filters to maintain smooth operation.

5. Bilge Cleaning & Oil Spill Management

  • The bilge area accumulates oil and sludge, which can pose environmental and safety hazards.

  • RXMARINE’s Oil Spill Dispersants & Bilge Cleaners effectively break down oil and prevent pollution.

6. Corrosion Prevention

  • Saltwater exposure accelerates corrosion in pipes, tanks, and metal surfaces.

  • Apply corrosion inhibitors and protective coatings to extend the life of engine room components.

Best Practices for Engine Room Maintenance

  • Implement a Routine Inspection Schedule – Daily, weekly, and monthly checks help identify problems early.
  • Train Crew Members – Ensure engineers and crew are well-trained in maintenance procedures.
  • Use High-Quality Marine Chemicals – Investing in premium cleaning, degreasing, and protective products ensures longevity and efficiency.
  • Document Maintenance Activities – Keeping detailed logs helps in audits, repairs, and regulatory compliance.
Images: Alt

M.DET-300

Product Code: RXSOL-16-1029-005

Size:

Color:

Product Short Description: General Purpose Degreaser
Product Technical Specification:

STRUCTURE  :
HEAD - Molecule have a long chain non polar Hydrocarbon, whose structure can be Studied as follows:-
Head : It is water soluble & ‘-‘Vely charged.
Tail   :   It is oil soluble.

CLEANSING ACTION 

When solution  water is poured over the DIRTY surface  the  hydrocarbon Tail  of the each molecules peg in to it, while the (–ve) HEAD is held in water. The dirt or grease layer is then disloged from the skin by rubbing or from garment by tumbling  and stirring. Each grease globule thus separated in PIN CUSHIONED by hydrocarbon  TAILS with (-ve) HEADS out wards in water. The (-ve) HEAD globules keep apart by mutual repulsions & are said to have emulsified.The emulsified grease globules bearing dirt can be readly washed with water.

Remarks:
Images: Alt

M.DET-300

Product Code: RXSOL-25-1029-005

Size:

Color:

Product Short Description: General Purpose Degreaser
Product Technical Specification:

STRUCTURE  :
HEAD - Molecule have a long chain non polar Hydrocarbon, whose structure can be Studied as follows:-
Head : It is water soluble & ‘-‘Vely charged.
Tail   :   It is oil soluble.

CLEANSING ACTION 

When solution  water is poured over the DIRTY surface  the  hydrocarbon Tail  of the each molecules peg in to it, while the (–ve) HEAD is held in water. The dirt or grease layer is then disloged from the skin by rubbing or from garment by tumbling  and stirring. Each grease globule thus separated in PIN CUSHIONED by hydrocarbon  TAILS with (-ve) HEADS out wards in water. The (-ve) HEAD globules keep apart by mutual repulsions & are said to have emulsified.The emulsified grease globules bearing dirt can be readly washed with water.

Remarks:
Images: Alt
stock-clearance.png