RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,061 products across 71 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Corrosion Inhibitor

Corrosion Inhibitor for Gas Compressor

Part number
RXSOL-16-2069-210
Brand
RXSOL
Corrosion Inhibitor for Gas Compressor

Overview

Corrosion Inhibitor for Gas Compressor, is  formulated  using high quality hydrotreated and isodewaxed mineral base inhibitor  and a specialized additive package. The Corrosion Inhibitor for Gas Compressor  is designed in such a way that it has excellent performance. This Corrosion Inhibitor for Gas Compressor provide excellent protection against chemical corrosion caused by the presence of hydrogen sulfide (H 2 S) in the gas stream. The protective properties of the oil, low pour point, excellent shear resistance properties provide a long and trouble-free service life.

The Corrosion Inhibitor for Gas Compressor specially designed for equipment operating in aggressive chemical environments, are chemically inert and do not leave deposits in equipment during operation.

Technical specifications

Test type ASTM method Corrosion Inhibitor
ISO VG   100
     
Water content, ppm D6304 20
Acid number TAN, mgKOH/g D974 1.32
Flash and fire point D92  
Flash point, °C   243
Ignition temperature, °С   268
Kinematic viscosity, cSt D445  
40°C   107.2
100°C   11.7
Viscosity index D2270 116
Pour point, °C D97 -37
Demulsibility D1401  
Oil-Water-Emulsion (time in minutes)   39-40-1 (10)
Volatility by NOACK D972  
Losses in % mass   2.9 
Copper Tape Corrosion D130  
100°C, 3 hours   1A
Corrosion D665  
A - in distilled water   Pass
B - in sea water   Pass

These products are also available in other viscosity grades and packaging. Additional test results are available upon request. 

Applications

 

  • Oil-filled screw compressors
  • Piston compressors
  • Aggressive chemical environment
  • Characteristics and notes

    Features and benefits.

    Low pour point Suitable for low temperature operation
    Excellent lubrication High efficiency, lower costs
    Low volatility Maintenance minimization
    Corrosion protection (H 2 S) Work with sour gases

    Safety and SDS

    Read the safety data sheet before handling. Wear suitable gloves and eye protection.

    View safety data sheet
    Part Number RXSOL-16-2069-210
    Product Name Corrosion Inhibitor for Gas Compressor

    Company Details:

    RX MARINE INTERNATIONAL
    105, A wing , BSEL , TECH PARK.
    VASHI ,NEW BOMBAY 400703 INDIA

    Stock Point : Muscat - Barka, Fujairah, Mumbai, Kandla, Kolkata, Chennai, Vizag, Canada

    Phone +91 22 27815540 / 41 / 42
    Fax +91 22 2781 1318 :::AOH :0091 9821214367
    Email rxsolchemicals@gmail.com

    This product is classified as dangerous in accordance with the Preparations Directive 1999/45/EC.

    Hazardous Substance(s)

    EINECS /

    ELINCS NO

    SYMBOL

    R-PHRASES /

    NOTAS

    % (w/w)

    Thioglycolic Acid

    200-677-4

       T

    R23/24/25, R34

    1 - 5

    Imidazoline Salts

    Proprietary

    Xi

    R38, R41,R52/53

    5 - 10

    Quaternary Ammonium compound

    Proprietary

    C, N

    R22, R34, R50

    1 - 5

    Refer to Section 16 for descriptions of relevant risk phrases and Notas.

    HAZARD CLASSIFICATION :

    This product is classified as dangerous in accordance with the Preparations Directive 1999/45/EC.
    Toxic by inhalation, in contact with skin and if swallowed. Irritating to eyes and skin

    HUMAN HEALTH HAZARDS - ACUTE :

    INHALATION :

    Toxic by inhalation. Repeated or prolonged exposure may irritate the respiratory tract.

    SKIN CONTACT :

    Toxic in contact with skin. Can cause moderate irritation

    EYE CONTACT

     Irritating, and will injure eye tissue if not removed promptly

    INGESTION :

    Not a likely route of exposure. Toxic if swallowed

    PHYSICAL AND CHEMICAL HAZARDS

    Combustible

    INHALATION :

    Remove to fresh air, treat symptomatically. If symptoms develop, seek medical advice

    SKIN CONTACT

    Immediately flush with plenty of water for at least 15 minutes. If symptoms develop, seek medical advice.

     EYE CONTACT

    Immediately flush eye with water for at least 15 minutes while holding eyelids open. If symptoms develop, seek medical advice

    INGESTION

    Do not induce vomiting without medical advice. If conscious, washout mouth and give water to drink. If reflexive vomiting occurs, rinse mouth and repeat administration of water.

    NOTE TO PHYSICIAN

    Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition

    FLASH POINT :

    Non Flammable

    EXTINGUISHING MEDIA 

    Foam, Carbon dioxide, Dry powder, Other extinguishing agent suitable for Class B fires, For large fires, use water spray or fog, thoroughly drenching the burning material.
    Water mist may be used to cool closed containers.

    FIRE AND EXPLOSION HAZARD

    Non Combustible Liquid; may form combustible mixtures at or above the flash point. Empty product containers may contain product residue. Do not pressurize, cut, heat, weld, or expose containers to flame or other sources of ignition. May evolve oxides of carbon (COx) under fire conditions. May evolve oxides of nitrogen (NOx) and sulfur (SOx) under fire conditions. May evolve ammonia under fire conditions .

    SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING

    In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit

    PERSONAL PRECAUTIONS

    Restrict access to area as appropriate until clean-up operations are complete. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection). Stop or reduce any leaks if it is safe to do so. Ventilate spill area if possible. Remove sources of ignition. Ensure clean-up is conducted by trained personnel only. Do not touch spilled material. Have emergency equipment (for fires, spills, leaks, etc.)readily available. Notify appropriate government, occupational health and safety and environmental  Authorities

    METHODS FOR CLEANING UP

    SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, properly labeled container. Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim into recovery or salvage drums or tank truck for proper disposal. Clean contaminated surfaces with water or aqueous cleaning agents. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in compliance with regulations indicated in Section 13(Disposal Considerations)..

    ENVIRONMENTAL PRECAUTIONS

    Do not contaminate surface water

    HANDLING

    Do not get in eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. Do not breathe vapors/gases/dust. Keep the containers closed when not in use. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Ensure all containers are labelled. Do not use, store, spill or pour near heat, sparks or open flame

    STORAGE CONDITIONS

    Store in suitable labelled containers. Store the containers tightly closed. Store away from heat and sources of ignition. Have appropriate fire extinguishers available in and near the storage area. Connections must be grounded to avoid electrical charges

    SUITABLE CONSTRUCTION MATERIAL

    HDPE (high density polyethylene), Stainless Steel 304, Stainless Steel 316L, MDPE (medium density polyethylene), Nitrile, PTFE, Perfluoroelastomer, Compatibility with Plastic Materials can vary; we therefore recommend that compatibility is tested prior to use

    UNSUITABLE CONSTRUCTION MATERIAL

    Viton, Neoprene, Carbon Steel C1018

      

     MONITORING MEASURES

    A small volume of air is drawn through an absorbant or barrier to trap the substance(s) which can then be desorbed or removed and analyzed as referenced below 

      Substance(s)

    Method

     Analysis

    Absorbant

     Thioglycolic Acid

    US OSHA: CIM

     High pressure liquid chromatography

    Impinger containing De-ionised water

      

    ENGINEERING MEASURES

    General ventilation is recommended. The use of local exhaust ventilation is recommended to control emissions near the source. Laboratory samples should be handled in a fumehood. Provide mechanical ventilation of confined spaces

    PERSONAL PROTECTION 

      GENERAL ADVICE

    The use and choice of personal protection equipment is related to the hazard of the product, the workplace and the way the product is handled. In general, we recommend as a minimum precaution that safety glasses with side-shields and workclothes protecting arms, legs and body be used. In addition any person visiting an area where this product is handled should at least wear safety glasses with side-shields.

    RESPIRATORY PROTECTION

    Where concentrations in air may exceed the limits given in this section, the use of a half face filter mask or air supplied breathing apparatus is recommended. A suitable filter material depends on the amount and type of chemicals being handled.

     HAND PROTECTION

     When handling this product, the use of chemical use PVC Gloves should be replaced immediately if signs of degradation are observed. Breakthrough time not determined as preparation, consult PPE manufacturers.

     SKIN PROTECTION

    When handling this product, the use of overalls, a chemical resistant apron and rubber boots is recommended. A full slicker suit is recommended if gross exposure is possible.

    EYE PROTECTION

    Wear chemical splash goggles.

    HYGIENE RECOMMENDATIONS

    Use good work and personal hygiene practices to avoid exposure. Keep an eye wash fountain available. Keep a safety shower available. If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse. Always wash thoroughly after handling chemicals. When handling this product never eat, drink or smoke

     PHYSICAL STATE  Liquid
     APPEARANCE  Clear
     ODOR  Characteristic
     FLASH POINT

    NA

     SPECIFIC GRAVITY

    20 c° : 1.073

     pH (100 %)  NA
    Pour POINT

    -42°C

     Note: These physical properties are typical values for this product and are subject to change

     STABILITY  Stable under normal conditions.
    HAZARDOUS POLYMERIZATION

    Hazardous polymerization will not occur

    CONDITIONS TO AVOID

    Heat and sources of ignition including static discharges

    MATERIALS TO AVOID

    Contact with strong acids (e.g. sulfuric, phosphoric, nitric, hydrochloric, chromic, sulfonic) may generate heat, splattering or boiling and toxic vapors., Contact with strong oxidizers (e.g. chlorine, peroxides, chromates, nitric acid, perchlorate, concentrated oxygen, permanganate) may generate heat, fires, explosions and/or toxic vapors., Avoid contact with SO2 or acidic bisulfite products, which may react to form visible airborne amine salt particles., Certain amines in contact with nitrous acid, organic or inorganic nitrites or atmospheres with high nitrous oxide concentrations may produce N-nitrosamines, many of which are cancer-causing agents to laboratory animals

    HAZARDOUS DECOMPOSITION PRODUCTS

     

    Under fire conditions

    Oxides of carbon, Oxides of nitrogen, Oxides of sulfur, ammonia

    No toxicity studies have been conducted on this product

     SENSITIZATION

    This product is not expected to be a sensitizer

     CARCINOGENICITY

    None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists (ACGIH).

     For additional information on the hazard of the preparation, please consult section 3 and 12

     ECOTOXICOLOGICAL EFFECTS

     MOBILITY The environmental fate of this product under the defined conditions of the models. If released into the environment this material is expected to distribute to the air, water and soil/sediment in the approximate respective percentages (Air-<5%, Water- 30 - 50%, Soil/Sediment- 50 - 70%) The portion in water is expected to be soluble or dispersible

    PERSISTENCY AND DEGRADATION

    The organic portion of this preparation is expected to be readily biodegradable

    BIOACCUMULATION POTENTIAL

    Component substances have a low potential to bioconcentrate

    Use  authorized contractors and ensure compliance with EC, national and local regulations.

    Dispose of wastes in an approved incinerator or waste treatment/disposal site, in accordance with all applicable regulations. Do not dispose of wastes in local sewer or with normal garbage. This product is ashless and can be burned directly in appropriate equipment. This product is NOT suitable for disposal via municipal sewers, drains, natural streams or rivers.

    Empty drums should be taken for recycling, recovery, or disposal through a suitably qualified or licensed contractor.

    EUROPE WASTE CODE  16 03 05*- OFF SPECIFICATION BATCHES AND UNUSED PRODUCTS - Organic wastes containing dangerous substances. If this product is used in any further processes, the final user must redefine and assign the most appropriate European Waste Catalogue Code.

    Not classified as hazardous . Can easly transport by Land, Air and sea. Typical Proper Shipping Names for this product are as follows. 

     LAND TRANSPORT  
     Proper Shipping Name  PRODUCT IS NOT REGULATED DURING TRANSPORTATION.

    AIR TRANSPORT (ICAO/IATA)

     

    Proper Shipping Name

    PRODUCT IS NOT REGULATED DURING TRANSPORTATION

    MARINE TRANSPORT (IMDG/IMO)

     

    Proper Shipping Name

    PRODUCT IS NOT REGULATED DURING TRANSPORTATION

     

    CLASSIFICATION AND LABELLING  
     GOVERNING DIRECTIVE(S): Dangerous Substances Directive 67/548/EEC and Dangerous Preparations Directive 1999/45/EC.
     HAZARD SYMBOLS

    T

     

    Contains:..Thioglycolic Acid

     RISK PHRASES  

    R23/24/25 -

    Toxic by inhalation, in contact with skin and if swallowed

    R36/38 -

    Irritating to eyes and skin

    SAFETY PHRASES

     

    S24/25 -

    Avoid contact with skin and eyes

    S26-

    In case of contact with eyes, rinse immediately with plenty of water and seek medical advice

    S28 -

    After contact with skin, wash immediately with plenty of water.

    S45 -

    In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).

    INTERNATIONAL CHEMICAL CONTROL LAWS
    UNITED STATES
    The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710)

    CANADA :This product contains substance(s) which are found on the Non-Domestic Substances List (NDSL), or are not in compliance with other Canadian Acts.

    EUROPE: The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS inventories.

    JAPAN: All substances in this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed on the Ministry of International Trade & industry List (MITI).

    LIST OF RELEVANT R-PHRASES AND NOTAS IN SECTION 2
    R10 - Flammable.
    R22 - Harmful if swallowed.
    R23/24/25 - Toxic by inhalation, in contact with skin and if swallowed.
    R34 - Causes burns.
    R35 - Causes severe burns.
    R38 - Irritating to skin.
    R41 - Risk of serious damage to eyes.
    R50 - Very toxic to aquatic organisms.
    R52/53 - Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment.

    The information provided about the product on this Safety Data Sheet  has  been  compiled  from  knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties.The data given here only applies  when  product  used for proper application(s). The productis not sold as suitable for other  applications -  usage  in  such  may  cause  risks  not mentioned in this sheet. Do not  use for other application(s) without seeking advice from manufacturer.

    DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

    Request the signed SDS as PDF

    Availability

    Corrosion Inhibitor for Gas Compressor manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Corrosion Inhibitor for Gas Compressor at a competitive price from us. We have ready stock of Corrosion Inhibitor for Gas Compressor in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.