Drilling Fluids & Mud Oil Field chemicals
Fluorescein Liquid Dye RX
- Part number
- RXSOL-81-8191-025
- Brand
- RXSOL
Overview
Fluorescein Liquid Dye RXSOL is a water-based fluorescent tracer dye that meets the minimum biodegradation requirements, removing the need for a substitution warning unlike the standard fluorescein leak tracing dyes. Fluorescein Liquid Dye Rx provides a fluorescent colour which is visible to the naked eye and can be detected subsea by cameras, fluorimeters calibrated to the appropriate excitation / detection wavelength
.
Fluorescein Liquid Dye Rx is lower in toxicity towards operatives and marine organisms than other leak testing dyes, such as Rhodamine and is non-hazardous for supply and transportation.It is compatible with RXSOL Hydrotech 367 RX corrosion inhibitors and oxygen scavengers.
Technical specifications
| Appearance | Liquid |
| Colour | Brown Fluoroscent Greenish orange liquid |
| Solubility | Soluble In Water. |
| Melting Point | 0 °C |
| Relative Density | 1.0-1.07 @ 20c |
| Ph-Value, Conc. | 9-10 |
| Viscosity |
<5 Cps @ 20degc |
Applications
Fluorescein Liquid Dye RXSOL is a commonly used dye for hydro test operations .Fluorescein Liquid Dye RXSOL is a brown liquid which produces a red / pink solution once diluted in water. The solution then produces an orange fluorescence when excited with a blue or green light. For subsea detection of Fluorescein Liquid Dye RXSOL, an optimum excitation wavelength should be used.
Dosage and directions
Normal dose for application is approximately 100 ppm. Rx Marine can not stipulate an exact dose for Fluorescein Liquid Dye RXSOL . This is due to the strength of colour required being determined by a number of scenarios e.g. style and sensitivity of detection apparatus, sea bed depth and tidal currents. Generally, as a rule of thumb, the dye must not be dosed at below 100ppm for visual detection.
Detection of Fluorescein Liquid Dye RXSOL has been proven using the Leak Detection Systems.
Characteristics and notes
Handling :
No special procedures need to be observed. Normal precautions should be taken and protective clothing,
goggles and PVC/rubber gloves should be worn.
Packing : Available in 25 Litre, Pail, 210 Ltrs drums, 1,000 litre IBC’s capacity.
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name |
Fluorescein Liquid Dye Rx |
| Part Number | RXSOL-81-8191-025 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Chennai, Kolkata, Visakhapatnam, Fujairah, Muscat, Nairobi
| Phone | +91 22 27815540 / 41 / 42 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com/ |
| Name | CAS No | Weight % |
| Fluorescein Liquid | 00518-47-8 | Mixture |
Hazard Category: Not applicable
Hazard Statement: Not applicable
Inhalation: Remove person to fresh air
Eye Contact: Flush eyes with plenty of water. If irritation persists, seek medical attention.
Skin Contact: Wash with soap and water. Seek medical attention if irritation develops.
Ingestion: If conscious, rinse mouth and give victim large amounts of water. Seek medical attention.
Extinguishing Media: Material is not flammable. Use extinguishing media suitable to surrounding materials.
Special Equipment and Precautions: Use water to cool nearby containers and structures. Wear full protective equipment, including suitable respiratory protection.
Specific Hazards: None identified
Hazardous combustion products: None identified
Spill Procedures: Prevent spread of spill. Absorb with sand or inert material. Sweep or scoop into a disposal container. Flush spill area with water.
Incompatible Materials: Incompatible with strong acids.
Storage and Handling: Store in a cool, dry, well-ventilated area away from incompatible materials. Keep containers tightly closed and protect them from physical damage. Protect from direct light and minimize contact with air.
OSHA & ACGIH Exposure Limits:
Water None identified
Fluorescein, sodium salt None identified
Engineering Controls: Use adequate general or local exhaust ventilation to keep fume and/or dust levels as low as possible. Respiratory Protection: If use generates annoying or irritating dusts, mists or vapors, use a NIOSH approved respirator with a particulate filter. Skin/Eye Protective Equipment: Safety glasses. Facilities storing or utilizing this material should have readily accessible eyewash stations and safety showers. Select respirators and other safety equipment in accordance with regulations and based upon the particular conditions of use and risk of exposure. Always use safe chemical-handling and good industrial hygiene practices.
Apearance: Clear, dark reddish orange liquid
Odor:Not available
Odor Threshold:No odor
pH: Not available
Melting/Freezing Point: Not available
Initial Boiling Point and Boiling Range: Not available
Flash Point:Not available
Evaporation Rate: Not available
Flammable or Explosive Limits (% by volume in air) Solubility: Not available
Auto-Ignition Temperature: Not available
Vapor Density: Not available
Reactivity: No information available
Stability: Stable
Possibility of Hazardous Reactions: Hazardous polymerization will not occur
Conditions to Avoid: Excessive heat and exposure to light.
Incompatibles: Incompatible with strong acids.
Decomposition Products: None identified
Effects of Over Exposure:
Inhalation: None identified
Skin Contact: None identified
Eye Contact: None identified
Ingestion: None identified
Additional Effects: None identified
Chronic Effects: None identified
Target Organs: None identified
Reproductive Effects: None identified
Carcinogenicity: None identified
Persistence and degradability: No information available
Bioaccumulative potential: No information available
Mobility in soil: No information available
Other adverse effects: No information available
Disposal Procedures: Dispose of material and containers in accordance with all local, state and federal regulations
This product is not a regulated material for domestic ground transporation.
Environmental hazards: No information available
Special precautions: No information available
Bulk transport: No information available
Symbols & Classification: Xi Irritant
R- Phrases: R36 Ittitating to the Eyes
S- Phrases: S26 In case of contact with eyes, rains immidiately with planty of water and seek medical advice.
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall Rx Marine International be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if RX Marine International has been advised of the possibility of such damages.
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.
Availability
Packaging & Supply
Fluorescein Liquid Dye RX can be supplied in suitable industrial packaging depending on customer requirements, application and availability.
Supply: India | UAE | Oman
Applications: Marine | Industrial | HVAC | Water Systems | Leak Detection | Flow Tracing
Safety
Handle according to the current RXSOL SDS. Avoid unnecessary contact with eyes and skin and use appropriate PPE during handling. Prevent uncontrolled release to drains or natural waterways unless the product and application are specifically approved for such discharge.
For exact concentration, dosage, specifications, packaging and regulatory status, refer to the current RXSOL TDS/SDS/COA for the supplied batch.
Fluorescein Liquid Dye RX, Fluorescein liquid dye, fluorescent tracer dye, fluorescent leak detection dye, water tracing dye, leak detection chemical, fluorescent water dye, industrial tracer dye, marine tracer dye, water flow tracing chemical, fluorescent dye supplier, fluorescein dye India, fluorescein dye UAE, fluorescein dye Oman, RXSOL fluorescent dye.
Fluoroscent Greenish orange liquid manufacturer and supplier in Fujairah, Dubai, Sharjah, Abudhabi, Ajman, Muscat Barka Oman, Mumbai, Gandhidham, Chennai Ennore, Visakhapatnam, Kolkata, Paradip India, Sudan, Yemen, Nairobi Kenya Africa