pH Booster Morpholine Base

Size:

Color:

Product Short Description: RXSOL pH Boosters are morpholine based alkaline formulation,used as alkalinity source for boiler feed water. It is synergized with properties of pH boosting and water conditioning.
Product Technical Specification:

 

Properties Unit Typical Value
Form and Appearance - Clear Colorless Liquid
Odor - Characteristic
pH (neat) pH Alkaline
Solubility - Completely Soluble in Water
Remarks:

STORAGE & HANDLING

pH booster should be stored in an air tight container away from direct heat.
Always store at cool & dry place.
Handle using goggles & do not breathe in the vapours.
Wash thoroughly in case of contact. Do not swallow.

 

pH Control

Maintenance of proper pH throughout the boiler feedwater, boiler, and condensate systems is essential for corrosion control. Most low-pressure boiler system operators monitor boiler water alkalinity because it correlates very closely with pH, while most feedwater, condensate, and high-pressure boiler water requires direct monitoring of pH. Control of pH is important for the following reasons:

  • corrosion rates of metals used in boiler systems are sensitive to variations in pH
  • low pH or insufficient alkalinity can result in corrosive acidic attack
  • high pH or excess alkalinity can result in caustic gouging/cracking and foaming, with resultant carryover
  • speed of oxygen scavenging reactions is highly dependent on pH levels

The pH or alkalinity level maintained in a boiler system depends on many factors, such as sys-tem pressure, system metals, feedwater quality, and type of chemical treatment applied.

The corrosion rate of carbon steel at feedwater temperatures approaches a minimum value in the pH range of 9.2-9.6 . It is important to monitor the feedwater system for corrosion by means of iron and copper testing. For systems with sodium zeolite or hot lime softened makeup, pH adjustment may not be necessary. In systems that use deionized water makeup, small amounts of caustic soda or neutralizing amines, such as morpholine and cyclohexylamine, can be used.

In the boiler, either high or low pH increases the corrosion rates of mild steelThe pH or alkalinity that is maintained depends on the pressure, makeup water characteristics, chemical treatment, and other factors specific to the system.

The best pH for protection of copper alloys is somewhat lower than the optimum level for carbon steel. For systems that contain both metals, the condensate and feedwater pH is often maintained between 8.8 and 9.2 for corrosion protection of both metals. The optimum pH varies from system to system and depends on many factors, including the alloy used 

To elevate pH, neutralizing amines should be used instead of ammonia, which (especially in the presence of oxygen) accelerates copper alloy corrosion rates. Also, amines form protective films on copper oxide surfaces that inhibit corrosion.

Images: Alt



Disinfectant Liquid FOOD GRADE

Size:

Color:

Product Short Description: Effective disinfectant having broad applications for water application.
Product Technical Specification:

Physical Properties : 

Appearance : Clear liquid
Odour : Characteristic
PH Value Cons : 11
Solubility

: Water Miscible

 
Remarks:
Images: Alt



Car Wash Shampoo

Size:

Color:

Product Short Description: A new and exciting silicon base product treated for the really tough cleaning problem faced on the proper maintenance of AUTOMOBILES. our shampoo globules keep apart by mutual repulsion and are said to have been emulsified grease globules bearing dirt can
Product Technical Specification:

 

Appearance/Odour

: Liquid Green / Yellow, Pleasant odour

pH

: 8.5

Boiling point/boiling range

: 100 ºC

Melting point

: Not applicable.

Flammability (solid, gas)

: Not classified

Explosive properties

: Not classified

Oxidising properties

: Not classified

Flash point

: Not applicable.

Relative density

: 1

Water solubility

: Complete

Evaporation rate

: No data available

 
Remarks:
Images: Alt



LIME Marine Water Scale Remover

Size:

Color:

Product Short Description: LIME Marine is a safe, biodegradable marine descaler developed to dissolve problematic fouling mediums including calcium, rust, mussels, barnacles, tiger shells and other scale formed mineral deposits that hinder the performance of vital water systems
Product Technical Specification:

PHYSICAL STATE

: LIQUID, DARK LIQUID
BOILING POINT

: 105° C

SOLUBILITY IN WATER

: MISCIBLE

SPECIFIC GRAVITY, (WATER=1) :1.03 @ 25 DEGREE C
VAPOR PRESSURE

: 20.1mmHg @ 25 DEGREE C

VAPOR DENSITY, (AIR=1): : .62 @ 25 DEGREE C
pH

: UNREADABLE, GENERALLY < 3

EVAPORATION RATE, (WATER=1): :SLOW
Remarks:

LIME Marine does not corrode, erode, attack, oxidize or have other deleterious affects on virtually any metal or materials found in marine water systems such as: BRASS, IRON, LEATHER, CERAMIC ,WOOD, FIBER, PLASTICS FIBERGLASS, COPPER, STEEL, TITANIUM ,COPPER NICKEL ,RUBBER, GLASS, GELCOATS PAINTED SURFACES.

LIME Marine is an electrolyte, as are most cleaning agents. An electrolyte is any liquid that will transfer small electrical currents. Examples: salt water, vinegar, Coca-Cola. An electrolyte may cause plating in some types of equipment. This means a transfer of small amounts of one metal onto another metal according to the galvanic corrosion chart. In some instances, a thin coating of copper may be plated onto a steel drum while circulating an electrolyte such as RXLYME Marine. The only time plating occurs is when two dissimilar metals are in an electrolyte solution.

It is recommended, but not mandatory, that the LIME Marine solution be thoroughly mixed before using. Some settling of a dark precipitate may occur, resulting in an amber colored liquid, but has no negative affects upon the performance of the solution.

Images: Alt



Corrosion Inhibitor 1304

Size:

Color:

Product Short Description: It is a n Anti-Agglo merate Hydr ate Inhibitor that effectively p r events gas h ydrates forming blockages.
Product Technical Specification:
Remarks:
Images: Alt



Pet Coke Remover

Size:

Color:

Product Short Description: Innovative, concentrated liquid product specifically engineered to attack, penetrate and remove Coal Carbon, pet coke, lime deposition
Product Technical Specification:

PROPERTIES

Pet Coke Remover is a concentrated liquid solution containing powerful surface active agents, a corrosion inhibitor and aqueous chemical agents.
Appearance / Color : Clear, light yellow liquid.
Specific gravity         : 1.1–1.2 gr/cm3 at 20°C
pH                              : 11.5–12.5


 

Remarks:

Pet Coke STAIN removal concept - 
Coal and petcoke leaves stain,  its removal is important task during hold cleaning operation. Our expert has 2 suggestion for removal of such stain from the surface. 

1st one to use RX Tuff heavy-duty alkaline cleaner, which can apply as an emulsion, need time to take effect and are rinsed away with seawater. More than one application will be needed to remove stubborn stains. 

2nd one solution is much more effective than 1st one step. Here our expert suggests using New ORG on the spotted area where the residue is tightly deposited on the surface. " New ORG -RXSOL-20-2020-025 " this product is specialized to react with oily residue where any alkaline cleaner fails to emulsify. Uses of New ORG  chemicals for stain removal/cleaning principally dissolve and emulsify OIL RESIDUE stain completely which is resulting stain-free surface, Then without flushing with water follow 1st step.

Images: Alt



RXSOL PCS

Size:

Color:

Product Short Description: Innovative, concentrated liquid product specifically engineered to attack, penetrate and remove Coal Carbon, pet coke, lime deposition
Product Technical Specification:

PROPERTIES

RXsol PCS (Coal Remover) is a concentrated liquid solution containing powerful surface– active agents, a corrosion
inhibitor and aqueous chemical agents.
Appearance / Color : Clear, light yellow liquid.
Specific gravity         : 1.1–1.2 gr/cm3 at 20°C
pH                              : 11.5–12.5


 

Remarks:

SAFETY AND HANDLING

HANDLING

:

Handle with care. Store in a dry, cool and well ventilated environment.

Eye Contact

:

Eye contact. Otherwise, flush with plenty of water for a few minutes. Seek medical attention.

Skin Contact

:

Skin contact. Otherwise, wash contaminated area thoroughly with water. Seek medical attention.

Inhalation

:

Do not breathe gas/vapors. Otherwise, seek fresh air source at once. Seek medical attention. In case of insufficient ventilation, wear suitable respiratory equipment.

If Swallowed

:

Ingestion. Otherwise, consume a considerable quantity of water. Do not induce vomiting. Seek medical attention.

GENERAL

INSTRUCTIONS

:

Avoid spillage, splashing and mishandling. Precautionary measures for body protection are strongly recommended before use.

Images: Alt



Car Wash Shampoo 210 Ltr

Size:

Color:

Product Short Description: A new and exciting silicon base product treated for the really tough cleaning problem faced on the proper maintenance of AUTOMOBILES. our shampoo globules keep apart by mutual repulsion and are said to have been emulsified grease globules bearing dirt can
Product Technical Specification:

 

Appearance/Odour

: Liquid Green / Yellow, Pleasant odour

pH

: 8.5

Boiling point/boiling range

: 100 ºC

Melting point

: Not applicable.

Flammability (solid, gas)

: Not classified

Explosive properties

: Not classified

Oxidising properties

: Not classified

Flash point

: Not applicable.

Relative density

: 1

Water solubility

: Complete

Evaporation rate

: No data available

 
Remarks:
Images: Alt



Carburising Fluid Rx

Size:

Color:

Product Short Description: Gas carburising fluid is basically pit-pot type fluid used for hardening / case carburising / carbonitriding of various components made of steel such as railway part, auto parts, gears, precision turned components, construction machinery parts and any oth
Product Technical Specification:

PHYSICAL & CHEMICAL PROPERTIE

 

Colour & Appearance     

: Yellow liquid

Sp. Gravity @ 30°C

: 0.81

pH (neat)

: 8.00

Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Lime Remover HD 25 Ltrs

Size:

Color:

Product Short Description: LIME REMOVER HD is an innovative, concentrated liquid product specifically engineered to attack, penetrate and remove lime deposit accumulations from cargo and storage tanks. It is liquid product designed to Clean and eliminate limestone caustic lime de
Product Technical Specification:

Lime Remover HD is a concentrated aqueous solution consisting of a blend of special surfactants and specific corrosion inhibitors.

Appearance / Color   : Clear  liquid

Specific gravity         : 1.10–1.20 at 15°C

Solubility in water     : 100% Soluble

Boiling Point             : 100 °C

Remarks:

Lime Remover HD  is formulated with strong Surfactant agents and special corrosion inhibitors, sufficient enough to neutralize strong alkaline nature of LIME.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



HBI CARGO Hold Wash Concentrate RX 25 Ltrs

Size:

Color:

Product Short Description: HBI CARGO Hold Wash Concentrate RX is a versatile all-purpose QUALITY marine cleaning solution. It can be used as a powerful stand-alone cleaner for HBI CARGO . it can be used as a powerful\ stand alone cleaner for HBI CARGO dust and deposition .
Product Technical Specification:
Remarks:

HBI at Elevated Temperatures
The Master of the ship must notify the port authorities if hydrogen gas is detected in the ship holds or if abnormal temperatures are measured in the HBI cargo holds. The Harbor Master and qualified personnel are responsible for executing the action plan when a ship or barge arrives with HBI at the following temperature levels:

A. Greater Than 65° Celsius but Less Than or Equal to 80° Celsius
Proceed with the following actions:

1 > Before unloading the vessel, measure the HBI temperature in each hold and record the measurements in the temperature log book.
2 >  Unload the holds in the assigned zone and immediately transfer the HBI to the storage yard zone as described in PART II, Section 5.4 of this guide.

B. Temperature Greater Than 80° Celsius and Less Than or Equal to 150°
Celsius

Proceed with the following actions:
1 > Before unloading the vessel, measure the HBI temperature in each hold and record the measurements in the temperature log book. This should be done every two hours while the contingency is in effect.
2 >  Unload the holds with HBI at temperature less than 65º Celsius first, then those containing HBI between 65º and 100º Celsius. Continue unloading HBI with temperatures between 100º and 150º Celsius in the
first transfer station, using the movement sense of the belt as a
reference.
3 >  Transfer the HBI from the unloading zone clean and free of debris and flammable material, such as coal, coke and wood to the storage yard indicated by the client as follows:
Transfer the HBI during a maximum of three-minute intervals, and dose (i.e., mix the hotter with the cooler material to have an average temperature lower than the hottest one – no water to be used) the HBI that is at temperatures between 100° and 150° Celsius with cooler material for a maximum of two minutes. Stop the vibrating feeders for about five minutes, but keep the conveyor belts in motion. Repeat these steps until finished with HBI removal. While transferring the HBI, inspect the belt transfer system for any sign of overheating. In case of belt overheating, stop the HBI dosing and transfer but keep the transfer belts in motion until they cool. Take special care to avoid pouring water into hoppers and other equipment. Use a front-end loader to spread the HBI to a level of approximate 30 centimeter height to stop the reoxidation,  Verify that the belts are cooled down and resume HBI transfer per
the previous instructions.


C . Greater than 150° Celsius
Proceed with the following actions:
1 > Before unloading the holds, measure the HBI temperature in each hold and record the measurements in the temperature log book. This should be done every two hours while the contingency is in effect.
2 > Position the HBI with temperatures greater than 150° Celsius at the end of the reception area and spray with pressurized water. In this case, there is no option but to momentarily cool down the HBI.
3 >  When the temperature is reduced to between 80º and 150° Celsius proceed with the steps described in 6.3.2.2. Caution: Do not spray water on hot HBI that is steaming (i.e., emitting water vapor). 

Procedure If Hydrogen Concentration Is Over 1% (25% LEL)
1 > Inform the shipper immediately and seek expert advice.
2 > Keep the natural surface ventilation open at all times
3 > Monitor LEL in the holds continuously until level drops to less than 25 %.
4 > Avoid any possible ignition source on the vicinity.
5 > Care shall be taken as to prevent any spark generation.
6 > Monitor the hydrogen concentration in the holds and keep the surface ventilation (either natural or mechanical) until values fall below 1%.
7 > When hydrogen levels are within safe values, proceed as normal.
8 > On the contrary, additional ventilation should be applied to the space if available and re-testing should be conducted after a suitable interval.
9 > Contact the P & I Club and Shipper and follow the instructions of the appointed expert or surveyor.
10 > At sea, do not open the troubled hold without explicit instructions from the shipper or appointed expert or surveyor.
11 > Ensure there are no possible sources of ignition near the cargo spaces, adjacent spaces or open decks.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



NITRIC ACID 68 % 50 Kg

Size:

Color:

Product Short Description: Extra pure NITRIC , removes iron residue & forms an oxide layer that boosts the corrosion resistance of the stainless steel intended to improve the corrosion resistance
Product Technical Specification:
Remarks:

Nitric Acid (68%) Safety Data Sheet

 

Chemical Identity

Chemical Name

Nitric Acid

Chemical Classification

Inorganic Acid

Formula

HNO3

CAS Number

7697-37-2

UN Number

2031

Shipping Name

Nitric Acid

Codes / Label

Corrosive, Oxidiser, Class 8

Hazardous waste ID No.

16

Hazchem Code

2 PE

 

 

 

 

Physical / Chemical Data

Boiling Point / Range

120 Deg. C

Melting / freezing Point

- 40 Deg. C

PhysicalState

Watery Liquid

Specific Gravity

1.40

Solubility in water

Soluble

PH

Acidic

Appearance

Colourless to Brown

Odour

Choking Odour

 

 

 

Fire / Explosion Hazard Data

Flammability

No

LEL / UEL

Not Pertinent

Flash Point

Not Pertinent

Autoignition Temperature

Not Pertinent

Explosion Sensitivity to Impact

Stable

Explosion Sensitivity to Static Electricity

Stable

Hazardous Combustion Products

May emit poisonous oxides of
Nitrogen and Acid fumes

Oxidiser

Yes

Corrosive Material

Yes

Combustible / Flammable / Explosive Material

No

 

 

Health Hazards / First Aid Measures
Seek Medical help immediately in case of ingestion / inhalation / contact with skin. In the meanwhile following actions are recommended.

Inhalation

Remove the victim to fresh air area. Provide artificial respiration if required.

Ingestion

Give large quantities of water. Do not induce vomiting.

Contact with skin

Flush the affected area with plenty of water for long time.

 

 

 

 

Preventive Measures
Avoid contact with liquid or vapours. Provide air mask, rubber acid suit, hood, boots, gloves, safety goggles, face shield to the workmen. Water shower and eye wash basin should be provided near the workplace.

Spills
Dilute with water and neutralise with alkali.

 

Images: Alt
stock-clearance.png