Typical Properties :
| Appearance | Liquid clear |
| Type | Maleic Multipolymer |
| Odour | Odourless or Mild odor |
|
Molecular weight¹ |
2000 |
| pH | 6.5 - 7.50 |
| % Total solids | 50 |
| % Actives | 60-90 |
| Viscosity, as is, mPa.s/cps² | 400-1200 |

Clog Controller Biocide RXSOL-40-4009-050 should be dosed periodically at a rate of 75 - 150 ppm of the total system volume. In a badly fouled system an initial dosage rate of up to 250m1/m3 may be required which can be reduced once control is gained.In order to comply with Health & Safety recommendations Clog Controller Biocide RXSOL-40-4009-050 should be alternated with another non-oxidising or oxidizing biocide. It is always advisable to carry out a 'Control Of Substances Hazardous to Health' (COSHH) assessment before use.

| Main Ingredients | : | PROPYLENEGLYCOL (1,2-) 94% |
|
Inhibitors and
water
6
Inhibitors and water
|
: | 6 % |
| Colour Bright | : | Clear |
| pH of solution | : | 8.8 |
| Odour | : | PRACTICALLY ODOURLESS |
| Solubility in water | : | SOLUBLE |
| Boiling point | : | 162 oC |
| Freezing point | : | -32 oC |
| Viscosity | : | 58.1 cp at 20 oC |
| Reverse Alkalinity | : | Minimm 15.0 ml |
| Vapour pressure | : | .07 mbar at 20oC |
| Skin absorption/irritation | : | YES |
| TLV Country | : | |
| Pollution category 1994 | : |
III |
Propylene glycol is tolerated well by the skin and shouldn't cause redness or irritation. Propylene glycol is a penetration-enhancing humectant.
Propylene Glycol USP is a widely used ingredient in pharmaceutical, food, cosmetic, personal care, flavors and animal feed applications; an overview of typical uses of Propylene Glycol USP as below.It must be emphasized that it is the user’s responsibility to consult area and country-specific regulations for details of approved use.

RX MARINE INTERNATIONAL are continiously working in water treatement sector, And developed many unique product to avoid corrosion and scale depositon in cooling water system. Here I wants to keep our experiment results with you.Corrosion inhibitor for closed cooling systems containing molybdate/phosphonate ( RXSOL-40-4018-025 ). Sodium molybdate has the advantage in that the dosing of lower ppm's of molybdate allow for lower conductivity of the circulating water. Sodium molybdate at levels of 50-100 ppm offer the same levels of corrosion inhibition that sodium nitrite at levels of 800+ ppm. By utilizing lower concentrations of sodium molybdate, conductivity is kept at a minimum and thus galvanic corrosion potentials are decreased.
Before testing of Nitrite level, Here is some point and guideline, what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate.
for a period of time.
If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.
Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-

| Appearance | Clear Colourless Liquid | Vapor Density Heavier than air |
| Flash Point | 63°C (Closed Cup) |
Stability : Very stable understandard, normal conditions |
| Compatibility | ||
| Metal Plastic Rubber |
No known effect No Known effect May swell |
Note: After use the product must always be well sealed in the drum. |
| Packaging | Order No.: | Size (in kgs./lts.) |
| RXSOL-16-1009-025 | 5, 7, 25 Lts |
Always keep container tightly closed and away from heat and sunlight.



Trisodium Phosphates is available in different forms and helps in softening the water and removes the soil content. Available in
Used for
Widely Used in
TSP is a strong base and can cause severe eye damage and can burn unprotected skin.
Wear suitable clothing and eye protection. Keep away from skin and out of gloves.
Any foliage near where TSP is to be used should be soaked with plain water prior to the application of TSP, and rinsed down afterward. Be sure to read and follow all warnings on the product's packaging.
TSP is a very strong cleaner at the dilutions normally used, which vary from 1/2 cup TSP to 2 gal. warm water for "heavy duty cleaning" to 1 cup TSP to 3 quarts warm water for "ridiculously heavy duty cleaning" (source The Savogran Company). For mildew killing, household bleach is added to the TSP/water mixture. The recommended ratio is 1 part household bleach to 4 parts water.


Red Cleaning Liquid

| Chemical Formula | : C6H15NO2 |
| Structural Formula | : [CH3CH(OH)CH2]2NH |
| Molecular Wt. | : 133,19 g/mol |
| Sp. Gr. at 25ºC | : 1.019 g/cm3 |
| pH | : 12-13 |
| Boiling Point | : 111°C |
| Freezing Point | : 13°C |
| Colour (APHA) | : 40 max. |
| Flash Point (closed cup) |
: ASTM D3828 none below
boiling point
|
| Solubility in water | : Soluble |
Specification ::
| CAS-No. | : 108-18-9 |
| EC-No | : 203-820-9 |
| Appearance | : Clear Liquid |
| Odour | : Ammoniacal |
| Solid Content | : 85-90% |
| Impurities % by wt. by GC |
: 0.10% max. |
| Phone | +91 22 65113333 / 5555 / 9999 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| 123@rxmarine.com | |
| Website |
www.rxmarine.com |
| Phone | +91 22 65113333 / 5555 / 9999 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| 123@rxmarine.com | |
| Website |
www.rxmarine.com |