Answer
3–5 litres of cleaning solution per m² of cooler surface, or by engine power: 2–3 L for 6,000–12,000 HP, 4–5 L for 12,000–24,000 HP, 5–6 L above 24,000 HP; in general 10–25% in fresh water depending on contamination.
Detailed question
What is the ACC9 dose?