Answer
Degrease the part, apply the solution by spray or immersion, keep wet for 6 minutes, rinse and inspect; any copper (pink) colour means free iron is present and the test fails. Use only on austenitic (300-series) stainless; other grades can give false failures.
Detailed question
What is the copper sulphate test procedure?
Products