Refrigerant R410a

Freon 410A is the leading HFC refrigerant for replacing R-22 in positive displacement residential and light commercial air-conditioning and heat pump systems.
Part number
RXSOL-66-6625-010
Category
Gasses
Brand
RXSOL
Refrigerant R410a

Overview

Freon 410A is the leading HFC refrigerant for replacing R-22 in positive displacement residential and light commercial air-conditioning and heat pump systems. It has higher cooling capacity and significantly higher pressure than R-22 and should be used only in systems specifically designed for R-410A A Synthetic HFC refrigerant which is harmless to the ozone layer.

Technical specifications

Contents : 12.30
Weight : 9.5 Kgs
Colour : Rose
ODP/GWP : 2090

ODP = Ozone Depletion Potential
GWP = Global Warming Potential (IPCC Fourth Assessment Report - AR4)

Features

  • All refillable cylinders are inspected prior to refilling.
  • Residue refrigerant recovered to prevent environmental damage.
  • Content is 100% genuine refrigerant from approved producer.
  • Conforms to ARI-700 purity standard.
  • For new systems only


Benefits

  • Worldwide compliance
  • Assured quality
  • Refillable cylinders

Applications

The gas is used in a variety of maritime refrigeration applications such as low, medium and high temperature applications (evaporating temperatures of -45 to +8° C). It is also used for New residential and commercial air conditioning and heat pumps.

Characteristics and notes

Features
 

  • All refillable cylinders are inspected prior to refilling.
  • Residue refrigerant recovered to prevent environmental damage.
  • Content is 100% genuine refrigerant from approved producer.
  • Conforms to ARI-700 purity standard.
  • For new systems only


Benefits
 

  • Worldwide compliance
  • Assured quality
  • Refillable cylinders

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet


Product Name Freon Refrigerant R410a
Part Number RXSOL-66-6625-010

Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.

VASHI ,NEW BOMBAY 400703 INDIA


Stock Point : Mumbai, Kolkata, Chennai, Gandhidham, Visakhapatnam, Fujairah, Muscat

Phone +91 22 27815541  /  42
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
Website www.rxmarine.com
Ingrident  CAS Number Weight Percentage
Difluoromethane                                     75-10-5  50%
Pentafluoroethane 354-33-6 50%
Main Hazards Adverse Contains a liquefied gas. Contact of liquid health effects may cause frostbite and injury to the cornea. In high concentrations may cause  asphyxiation
Chemical hazards Heating will cause a rise in pressure with a risk of bursting. On Combustion, toxic gases are released
Biological hazards Contact with liquid could cause frost burns
Vapour inhalation High exposures may cause an abnormal heart rhythm and prove suddenly fatal. May have a narcotic effect, very high concentrations may cause  anaesthetic effects and asphyxiation
Eye Contact Vapour - unknown effect  Liquid - could cause serious burns
Skin Contact Vapour - unknown effect
Ingestion Liquid - see vapour inhalation above
Skin Take off all contaminated clothing immediately if not stuck to the skin. Flush area with lukewarm water. Do not use hot water. If frostbite has occurred call a physician.
Eyes Hold eyelids apart and flush eyes with plenty of water for at least 15 minutes. Get medical attention.
Inhalation Remove from exposure, lie down. Move to fresh air. Keep patient warm and at rest. Artificial respiration and/or oxygen may be necessary. Consult a physician.
 Ingestion  This is not considered a potential route of exposure. 

General Advice 

Never give anything by mouth to an unconscious person. When symptome persist or in all cases of doubt seek medical advice.

Extinguishing media:  Water spray, Foam, Dry chemical Carbon dioxide (CO2). Use extinguishing measures that are appropriate to local and surrounding environment. Cool cylinders/tanks with water spray. 
Special hazards arising from the mixture  Vapours may form explosive mixtures with air. Vapours are heavier than air and may spread along floors. Vapours or gases may travel considerable distances to ignition source and flash back. Fire or intense heat may cause violent rupture of packages. Hazardous thermal decomposition products: carbon oxides, hydrogen fluoride, carbonyl fluoride
Advice for fire-fighters:  In the event of fire wear self-contained breathing apparatus. Use personal protective equipment. Wear neoprene gloves during cleaning work after a fire. 

 

 Personal Avoid contact with skin and eyes. Do not breathe gas. For further information refer to 8 “Exposurecontrols/Personal Protection” Heavy vapours. Shut off low-level opening in the vicinity (ventilation shafts, drains) Prevent the product from entering cellars, basements of pits. Stop the leak. Ventilate spillage area and basements
 Environmental Prevent the product from spreading into the precautions environment. Contain the spilled material by bunding
Small spills Shut off source of product. Ventilate area
Large spills  Evacuate the area. Shut off the source of the spill if this can be done without risk. Restrict access to the area until completion of the clean-up procedure. Ventilate the area using forced-draft if necessary.

 Handling Advice on handling: Avoid breathing vapours or mist. Avoid liquid contact with skin and clothing. Provide sufficient air exchange and/or exhaust in work rooms. Advice on protection against fire and explosion: No special measures against fire required.
 Storage Do not drag, slide or roll cylinders. Never attempt to lift cylinder by its cap. Use a check valve or trap in the discharge line to prevent hazardous back flow into the cylinder. Keep at temperature not exceeding 52oC. Keep cylinders tightly closed in a dry, cool and wellventilated place.
 Storage temperature: Less than 52oC .
 Occupational As R410A is a simple asphyxiant, avoid exposure hazards any areas where spillage has taken place. Only enter once testing has proved the atmosphere to be safe, and remember that the  gas is heavier than air
 Engineering Engineering control measures are preferred to control measures reduce exposures to oxygen depleted atmospheres. General methods include forced-draft ventilation, separate from other exhaust ventilation systems. Ensure that  sufficient fresh air enters at, or near, floor level.
Personal protection Self-contained breathing apparatus should always be worn when entering area where oxygen depletion may have occurred. Safety goggles, gloves and shoes or boots should be worn when  handling cylinders
Skin No known effect.

                         

Colour:                                        Clear colourless liquid and vapour.

Odour :                                        Ethereal

Molecular weight:                       72.59 g/mole

Boiling Point/range:                   - 51.2 to -51.1oC (boiling range)

Flash Point:                                 Does not flash. Non-flammable

Vapour pressure:                        14.706 Bar (14706 hPa) at 20oC

Liquid Density:                              1081 kg/m3 at 20oC

Conditions to avoid  The dilution of oxygen concentration in the atmosphere to levels which cannot support life Never use cylinders as rollers or supports, or for any other purpose than the storing of R410A. Never expose the cylinders to excessive heat, as this may cause sufficient build-up of pressure to  rupture the cylinders
Incompatible Since the performance of plastic materials is affected by polymer variations, compounding agents, fillers, and moulding processes, verifying compatibility using actual fabricated parts under end-use conditions is advised. The effects on specific elastomers depend on the nature of the polymer, the compounding formulation used and the curing of vulcanizing conditions. Actual samples should be tested under end-use conditions before specifying elastomers for critical  components
 Hazardous Decomposition On combustion or on thermal decomposition  (pyrolysis) releases: toxic gases (Fluorinated compounds) (hydrofluoric acid)

Acute Toxicity (TWA 8+12 hr)

Skin & eye contact No known effect

Chronic Toxicity No known effect

Carcinogenicity No known effect

Mutagenicity No known effect

Reproductive Hazards No known effect

(For further information see Section 3. Adverse health effects)

Prevent the product from spreading into the environment

 Disposal Methods Do not allow the product to be released into the environment. Consult the manufacturer of supplier for information regarding recovery and recycling of the product.

UN Number UN 3163
Proper Shipping Name Liquefied gas, n.o.s., (Pentafluoroethane, Difluoromethane)
Hazard Class 2.2
Packing Group  Not applicable
 TOXIC SUBSTANCES CONTROL ACT (TSCA)
 Tsca Inventory Status Listed on the TSCA inventory
 Other Tsca Issues Subject to Section 12(b)  export notification. May contain 0-10ppm Ethane, 2- chloro-1,1,1-trifluoro, CAS#75-88-7
 SARA TITLE III / CERCLA Reportable Quantities” (RQs) and/or “Threshold Planning Quantities” (TPQs) exist for the following ingredients.
Ingredient Name Sara / No ingredients listed in this section.Spills or releases resulting in the loss of any ingredient at or above its RQ requires immediate notification to the National Response Center USA  [(800) 424-8802] and to your Local Emergency Planning Committee.
Section 311 Hazard Class  Immediate Pressure
Sara 313 Toxic Chemicals The following ingredients are SARA 313 “Toxic Chemicals”. CAS numbers and weight percents are found in Section 2. .
    Ingredient Name                                                          Comment
    Chlorodifluoromethane (HCFC-22)                          None
State Right-To-Know In addition to the ingredients found in Section 2, the following are listed for state right-to-know purposes.
Ingredient Name                                                             Weight %                                  Comment
No ingredients listed in this section
Additional Regulatory Information R-410A is subject to U.S. Environmental Protection Agency Clean Air Act Regulations at 40 CFR Part 82.WARNING: Do not vent to the atmosphere. To comply with provisions of the U.S. Clean Air Act, any residual must be recovered. Contains Pentafluoroethane (HFC-125) and Difluoromethane (HFC-32), greenhouse gases which may contribute to global warming.
WHMIS Classification (Canada): This product has been evaluated in accordance with the hazard criteria of the CPR and the SDS contains all the information required by the CPR.
Foreign Inventory Status EU – EINECS
# 2065578 – HFC-125
HMIS Classification  Health – 1,
Flammability – 1,
Reactivity – 0
NFPA Classification Health – 2,
Flammability – 1,
Reactivity – 0
OSHA regulations For compressed gases: 29 CFR 1910.101
DOT classification Per 49 CFR 172.101
Clean Air Act Toxicity information per PAFT Testing

The information above is believed to be accurate and represents the  best information   currently    available  to us.  However,   we  make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and  we assume  no liability resulting from its use. Users should make  their  own  investigations  to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International  has been advised of the possibility of such damages.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Refrigerant R410a manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Refrigerant R410a at a competitive price from us. We have ready stock of Refrigerant R410a in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.