Concrete Truck Cleaner CRMC-83
- Part number
- RXSOL-41-4135-210
- Category
- Automobiles
- Brand
- RXSOL
Overview
A clear liquid, low-fuming acid detergent compound to use as a concrete truck cleaner or ready mix truck cleaner, works well for removing plaster, rust, scale, grease, oil, and road film also great for removing lime.
Technical specifications
|||
| Characteristic odor. |
N/A
| Vapor Density (Air = 1) | ||| |
|---|
.1
| Water Reactive | ||| |
|---|
Applications
Great ready mix truck cleaner, brick cleaner, concrete floor cleaner before applying floor sealer, concrete form cleaner, windows on concrete trucks, tools, and other cement handling equipment.
Dosage and directions
Using the proper dilution (1 part concrete truck cleaner concentrate to 3 -10 parts water), apply by spraying or brushing for ready mix truck cleaner. Allow surface to remain wet four to five minutes, while agitating with a brush. Rinse thoroughly with clear water, allow to dry. This concrete truck cleaner contains a soap and a low pH cleaner for concrete removal from trucks.
Characteristics and notes
Companies that need ready mix truck cleaner, cement contractors, and other accounts having accumulations of cement, plaster, rust, scale, grease, oil, and road film to be removed from equipment.
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | RXSOL-41-4135 |
| Product Type | Concrete Truck Cleaner (CRMC-83) |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point ::: Mumbai, Kandla, Kolkata, Visakhapatnam, Fujairah, Muscat Barka, Chennai, Surat, Canada, Kenya, Uganda
| Phone | +91 22 65113333 / 5555 / 9999 / 27611360 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com |
|
Chemical Name |
CAS Number |
SARA-III LIST |
OSHA PEL |
ACGIH |
OTHER LIM |
| ETHYLENE GLYCOL MONO BUTYL ETHER | 111-76-2 | Yes | 25 PPM | 25 PPM | d |
| PHOS PHORIC ACID | 7664-38-2 | Yes | 1mg/m3 | 3 PPM | d |
| AMMONIUM BIFLUORIDE ( EXP . LIMITS FOR FLUORIDEAS DUST ) | 1341-49-7 | No | N/E | 1 MG/M3 | d |
|
Appearance |
Clear to slightly hazy viscous pink liquid |
|
Odour |
characteristic odor. |
|
Contact with eyes |
May cause burns. |
|
Contact with skin |
May cause severe irritation & fluoride burns, which may not be |
|
Inhalation |
May cause severe irritation to upper respiratory tract. Not likely to be a problem under normal conditions of handling and use. |
|
Ingestion |
May cause systemic toxic ef fects as wel l as t issue damage to GI t ract . |
|
Eye Contact: |
Flush (including under lids) with water for 30 minutes. Get medical attention. |
|
Skin Contact: |
Flush with cold water for at least 15 minutes. Use alkaline soap. If irritation occurs, get medical attention. |
|
Ingestion |
DO NOT INDUCE VOMI T ING. Drink large quantity of water. Get immediate medical attention. |
|
Inhalation |
Remove to fresh air. If breathing is difficult, give oxygen. Get medical attention. |
- FLASH POINT AND METHOD USED:-Non-combustible
- EXTINGUISHER MEDIA:-Non-combustible. Use media appropriate to surrounding fire.
- SPECIAL FIRE FIGHTING PROCEDURE S :- Self-contained breathing apparatus
|
Respiratory Protection (specify type) : |
Not generally needed under normal conditions of handling and use. |
|
Protective Gloves: |
Neoprene or PVC. |
|
Eye Protection: |
Chemical goggles. |
|
Other Protective Clothing & Equipment : |
Eyewash stat ions & safety showers. |
|
Hygienic WorkPractices: |
Avoid contact with skin and avoid breathing vapors. |
|
Ventilation Requirements: |
Special ventilation is not generally needed under normal conditions of handling & use. |
|
Steps To Be Taken If Material Is Spilled Or Released: |
Contain spill. Do not contaminate sewers, ground or surface waters. Neutralize with soda ash or lime. Soak up in inert absorbent. Place in sealed, leak-proof, properly labeled containers |
| Waste Disposal Methods: | Dispose of in accordance with all local, state and federal regulations. |
|
Storage |
Store in original container. Keep container sealed when not in use. Shelf life one year. Protect from extreme heat or cold. |
| Other Precautios & / or Special Hazar s : | KEEP OUT OF REACH OF CHI LDREN |
|
FLASH POINT AND
METHOD USED |
Non-Combustible |
|
EXTINGUISHER MEDIA: |
Non-combustible. Use media appropriate to surrounding fire. |
|
SPCIAL FIRE FIGHTING PROCEDURES : |
Self-contained breathing apparatus. |
|
Appearance: |
Clear to slightly hazy liquid |
|
Odor |
Characteristic odor. |
|
Boiling Point: |
100ºC |
|
Vapor Pressure: |
N/A |
| Vapor Density (Air = 1): | N/D |
|
Solubility in Water: |
Miscible |
|
Specific Gravity (H2O=1): |
1.100-1.250 |
|
Evaporation Rate |
.1 |
| Water Reactive : | No |
- Incompatibility (Mat. to avoid): (Mat. to avoid): Bases, metals, glasses, carbides, acetylides, phosphides, silicides
- Conditions to Avoid: Contact with strong bases can cause violent reaction generating large amounts of heat.
|
Toxicological information |
No experimental data available. |
|
Inhalation |
Remove to fresh air. If breathing is difficult, give oxygen. Get medical attention. |
|
Contact with skin |
May cause severe irritation & fluoride burns, which may not be |
|
Contact with eyes |
May cause burns. |
|
Ingestion |
May cause systemic toxic ef fects as wel l as t issue damage to GI t ract . |
-
Availability
Concrete Truck Cleaner (CRMC-83) manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Concrete Truck Cleaner (CRMC-83) at a competitive price from us. We have ready stock of Concrete Truck Cleaner (CRMC-83) in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.