Antifreeze with Potassium Chromate

pH control and water softening ability. Potassium dichromate is added to antifreeze-antiboil as a corrosion inhibitor. The pH control is used to maintain an acid free solution. The water softening ability deters formation of mineral deposits Inhibi
Part number
RXSOL-60-6236-100
Brand
RXSOL
Antifreeze with Potassium Chromate

Overview

pH control and water softening ability. Potassium dichromate is added to antifreeze antiboil as a corrosion inhibitor.  The pH control is used to maintain an acid free solution.  The water softening ability deters formation of mineral deposits Inhibitor systems are available in various forms such as coolant filter elements, liquid and dry bulk inhibitor additives and as an integral part of permanent antifreeze.

Applications

Antifreeze with Potassium Chromate solution is most popular antifreeze to add in chilled water for prevention of ice formation. In general  GLYCOL only prevent formation of ice in chiller water system, while presence of  Potassium dichromate in antifreeze resulting as a corrosion inhibitor.  And its water softening properties prohibit mineral deposits in systems.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name Potassium Chromate Solution with Antifreeze
Product Type RXSOL-60-6236-100

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
SARA 313 Component  CAS Number Percent Comp. Dimension
 
Exposure
 Limits
 
Methanol (Methyl) CAS# 67-56-1

 25 - 40%

  OSHA TWA200 ppm,ACGIH STEL250 ppm
Potassium Chromate CAS# 7789-00-6 4 - 8% W/V TLV/TWA 0.05 mg/mƒ
Water, Deionized ASTM Type II CAS# 7732-18-5 90% V/V None Established

Causes severe irritation and burns. May be harmful if swallowed. May be harmful if absorbed through the skin. Avoid breathing vapor or dust.Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.

Emergency Overview:Danger! Strong Oxidizer. Contact With Other Material May Cause Fire. Harmful If Swallowed Or Inhaled. May Cause Burns To Skin And Eyes. May Cause Allergic Skin Or Respiratory Reaction.

Inhalation:May irritate the mucous membranes. May cause lung edema. Symptoms may include
sore throat, shortness of breath, inflammation of nasal passages, coughing, and wheezing. Any exposure may cause an allergic reaction. Asthma-like symptoms and life-threatening shock may result.

Ingestion:Corrosive. May produce abdominal pain, nausea and vomiting.

Skin:Corrosive. May cause skin burns.

Eye Contact:May cause severe irritation and pain.

Chronic Exposure:Prolonged skin contact may cause an allergic reaction with dermatitis.

Aggravation of Pre-existing Conditions:Persons with impaired respiratory function may be more susceptible to the effects of the substance.

Causes severe irritation and burns. May be harmful if swallowed. May be harmful if absorbed through the skin. Avoid breathing vapor or dust. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.  

SKIN:

Remove contaminated clothing. Wash exposed area with soap and water. if irritation persists, seek medical attention
EYES: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally.Seek Medical Aid.
INHALATION: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen
INGESTION: Give several glasses of milk or water. Vomiting may occur spontaneously, but DO NOT INDUCE! Never give anything by mouth to an unconscious person.

Fire Extinguisher Type:

Alcohol Resistant Foam or Carbon Dioxide
Fire / Explosion Hazards: Material will burn in a fire.
Fire Fighting Procedure: Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and clothing.

Eliminate Ignition Sources. Absorb with vermiculite or other inert material. Place in container. If fire hazard
exists, blanket spill with alcohol foam or use water spray Ventilate area of leak or spill. Wear appropriate personal protective equipment as specified In section 8. Isolate hazard area. Keep unnecessary and
unprotected personnel from entering.Contain and recover liquid when possible. Neutralize with alkaline
material (soda-Ash, lime), then absorb with an inert material (e.g., vermiculite, drysand, earth), and place
In a chemical waste container. Do not use combustible materials, such as saw dust. Do not flush
to sewer! Us regulations (cercla) require reporting spills and releases to soil, Water and air in excess of reportable quantities.

Wash thoroughly after handling. Remove contaminated clothes and wash before reuse. Use with adequate ventilation. Keep in tightly closeD container. Do not expose to sources of ignition.Containers of this material may be hazardous when.

Respiratory Protection

None required
Ventilation  Local
OTHER Mechanical
Protective Gloves Wear appropriate gloves to prevent skin exposure
EYE PROTECTION Safety Glasses w/Side Shields
Other Protective Equipment Wear appropriate clothing to prevent skin exposure
BOILING POINT information not available
VAPOR PRESSURE  information not available
MELTING POINT information not available
VAPOR DENSITY  not available
EVAPORATION RATE information not available
Appearance /Odors Clear, yellow, odorless liquid
Flash Point

Not applicable

Specific Gravity information not available
Percent Volatile by ~95%
Evaporation Standard  
Auto Ignition Temp

Not applicable

Lower Flamm. Limit in Air Not applicable
Upper Flamm. Limit in Air  Not applicable
Solubility in Water Soluble

STABILITY

Stable

CONDITIONS TO AVOID

Avoid contact with incompatible materials.

MATERIALS TO AVOID

Bases, organic material, Halogens,metalacetylides, Oxides, nitric acid and potassium tertbutoxide.

HAZARDOUS DECOMPOSITION PRODUCTS

Oxides of carbon and formaldehyde if heated.

HAZARDOUS POLYMERIZATION

will not occur
Conditions to Avoid  None known

Carcinogenic References: NTP Carcinogen - Known: Yes - Anticipated: No, IARC Category- 1

No information found.

Disposal should be made in accordance with federal, state and local regulations.

DOT Classification: UN1230, Methanol, 3, PG II
 

DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations.

All components listed on TSCA Inventory.

May cause eye skin and respiratory burns. May cause alllergic skin reaction. May cause damage to internal organs. Corrosive properties! If ingested do not induce vomiting. Give large amounts of water. Get immediate medical attention. Potassium Chromate is listed as a substance which may be reasonably anticipated to be
a carcinogen by the National Toxicology Program (NTP).Acute/Chronic effects: Nasal septum irritation, skin ulcer,sensitization and dermatitis, leukocytoses, leukopenia,monocytosis, eosinophilia, and conjunctivitis. Conditions aggravated: Chronic respiratory disease, pre-existing eye, skin, and blood disorders, impaired kidney or liver function.

INGESTION:May be poisonous or fatal or cause blindness if swallowed.Exposure may adversely affect people with chronic disease of thecentral nervous system, skin, gastrointestinal tract or eyes.

                                                                      Flammability
 

Health                                                                                                      Reactivity

Revisions

  NFPA
6/17/2010 0.1 updated msds to 16 section from 10 section msds. STN
   0

 The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Antifreeze with Potassium Chromate manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Antifreeze with Potassium Chromate at a competitive price from us. We have ready stock of Antifreeze with Potassium Chromate in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches