RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,061 products across 71 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Automobiles

SUPER REMOVER Silicon Sealant Remover

SUPER REMOVER
Part number
RXSOL-41-8630-025
Category
Automobiles
Brand
RXSOL
SUPER REMOVER Silicon Sealant Remover

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name

SUPER REMOVER

Product Type RXSOL-41-8630-025

Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Mumbai, Kolkata, Chennai, Kandla, Visakhapatnam, Fujairah, Muscat, Nairobi

Phone +91 22 65113333/ 5555 / 9999 / 27611360 / 27815540
Fax +91 22 2781 1318 :::AOH :0091 9322594669
Email rxsolchemicals@gmail.com

Benzyl alcohol 3%-4%           Xn       Harmful if inhaled or swallowed.

Watery solution of alcohols and alkylpolyglycolethers.

3.1 Health risks: exposure to the product does not involve any particular health risks.
Frequent contact can irritate the eyes and skin. Prolonged inhalation of the vapours can irritate the respiratory system and produce narcotic effects.
Swallowing can cause abdominal pain and nausea.

3.2 Environmental risks: -

4.1 Inhalation: move the person to an open well-ventilated environment and leave him/her to rest. If the patient has breathing difficulty, perform artificial respiration and seek medical advice.

4.2 Skin contact: remove and wash all clothes contaminated by the product. Wash the skin with plenty of water and neutral soap. If the irritation persists, seek medical advice.

4.3 Eye contact: wash eyes with plenty of water. the irritation persists, seek medical advice.

4.4 Swallowing: do not induce vomiting. Seek medical advice. Never force an unconscious person to drink.

4.1 Suitable extinguishing products: chemical powders, alcohol-resistant foams, carbon dioxide, nebulised water (use water to cool containers exposed to fire).

4.2 Extinguishing products not to be used for safety reasons:

4.3 Possible exposure risks combustion produces carbon monoxide deriving from combustion products:

4.4 Special protective equipment wear protective fireproof clothing, including breathing apparatus for fire extinguishing personnel:

6.1 Individual precautions: wear suitable clothing and protective waterproof gloves. In poorly ventilated environments, adequately protect the respiratory system.

6.2 Environmental precautions: keep the product well away from refuse dumps, surface and underground water and the soil.

6.3 Cleaning methods: absorb the leak with inert materials (sand, earth, vermiculite, etc.) and mechanically collect in suitable containers.
Dispose of the waste in accordance with the law. Wash the contaminated area with water.

6.4 Other precautions: avoid contact with strong oxidising agents, acids and bases.

7.1 Handling: Adopt all routine precautions for the handling of chemicals. When using the product, keep well away from foodstuffs and items for consumption. Keep well away from all equipment that generates sparks and all sources of ignition.

7.2 Storage: the product must be kept in the original closed containers, in a cool ventilated place, protected from sunlight, at a temperature not below 0°C and not exceeding 50°C.

8.1 Respiratory protection: for occasional use, employ in adequately ventilated environments. If not, wear a mask with filter for organic vapours.

8.2 Hand protection: use protective waterproof gloves.

8.3 Eye protection: use protective goggles.

8.4 Skin protection: use protective clothing.

8.5 Specific hygiene precautions: wash your hands at the end of work. Keep work clothes in a separate place. Do not smoke or eat during use.

Appearance Liquid
Smell of alcohol
pH   -
Boiling point 55-100°C
Autoinflammability above  300°C
Flash point 10°C
Comburent properties data not available
Vapour pressure data not available
Relative density 1 g/ml (25°C)
Solubility in water soluble
Density of the vapours above 1(air=1)

10.1 Conditions to be avoided: the product is normally stable. The vapours can form explosive mixtures with the air.

10.2 Substances to be avoided: the product is incompatible with strong oxidising agents. The product can dissolve certain plastics.

10.3 Hazardous decomposition carbon monoxide can form as a result of ignition. products:

11.1 Inhalation: 11.1.1. symptoms: irritation of respiratory system, drowsiness.

11.2 Swallowing: 11.2.1. symptoms: irritation of mouth and throat, abdominal pain, headache, nausea, general weakness.

11.3 Skin contact: 11.3.1. symptoms: irritation of skin.

11.4.Eye contact: 11.4.1. symptoms: irritation of eyes with smarting.

Use in accordance with good working practice, avoiding dispersion of the product in the environment.

 

Dispose of in compliance with current local and national regulations (Decree Law of 5th February 1997 no.22 and subsequent amendments).Use of the product is subject to observance of the laws concerning hygiene and safety at work (Presidential Decree no. 203/88, Presidential Decree no. 303/56).

Ground Transportation: Limited quantity exception applies for inner packaging less than 1 liter. Requires limited quantity label. Air Transportation: UN1993; Flammable Liquid NOS (Benzyl alcohol); 3; II. Check for limited quantity values. Maritime Transportation: UN1993; Flammable Liquid NOS (Benzyl alcohol); 3; II. Check for limited quantity values.

 

15.1 Hazard labelling – Decree Law of 16th July 1998

The product contains: - Hazard indications: F highly flammable

Hazard warnings: Highly flammable

Precautions: Keep out of the reach of children . If swallowed, seek medical advice immediately andshow this container or label. Keep container in a well-ventilated place. Keep away from sources of

ignition - No smoking. Do not breathe vapour.

16.1 Main sources used in drawing up the sheet:

“Dangerous properties of industrial materials”, 8th edition Handbook of toxic and hazardous chemicals and carcinogens
While this information and recommendations set forth herein are believed to be accurate and reliable, it is provided without warranty regarding its accuracy. RXSOL SYSTEMS MAKES NO WARRANTY WITH RESPECT HERETO AND DISCLAIMS ALL LIABILITY FROM RELIANCE THEREON. Users must determine safe conditions for use and assume liability for any loss, injury, damage or expense resulting from use of this product.
____________________________________________________________________________________________________
N/A = Not applicable N/D = Not determined N/E = Not established

Request the signed SDS as PDF

Availability

SUPER REMOVER Silicon Sealant Remover manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of SUPER REMOVER Silicon Sealant Remover at a competitive price from us. We have ready stock of SUPER REMOVER Silicon Sealant Remover in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches