Power Plant / Heavy Industries
ECO Safe Descaler
- Part number
- RXSOL-37-1048-030
- Category
- Power Plant / Heavy Industries
- Brand
- RXSOL
Overview
- Calcium carbonate scale
- Magnesium deposits
- Hard-water scale
- Mineral deposits
- Light iron oxide/rust deposits
- Metal oxides
- Inorganic deposits
- Carbonate-based deposits
Technical specifications
| Property | Typical Value |
|---|---|
| Appearance | Clear to slightly hazy liquid |
| Colour | Colourless to pale yellow |
| Odour | Mild acidic |
| Chemical nature | Organic acid |
| pH, neat product | Typically <2 |
| Specific gravity @ 20°C | Approx. 1.12-1.18 |
| Solubility in water | Completely miscible |
| Flash point | Not applicable / non-flammable aqueous formulation |
| VOC | Very low |
| Chloride | Typically negligible, subject to raw materials |
| Foaming | Moderate Foaming |
| Boiling point | Approximately near that of aqueous solution |
| Corrosion Inhibitor | Specialized corrosion inhibitor addition |
| Shelf life | Typically 24 months in unopened original container |
This descaling liquid contains special quaternary corrosion inhibitors which prevent excessive corrosion in the systems provided other parameters are followed. RXSOL ECO Safe Descaler is not a normal descaling liquid: this corrosion inhibitor and other wetting agents provide essential features to this descaling liquid.
Applications
- Calcium carbonate
- Magnesium carbonate
- Mineral scale
- Iron deposits
- Water-scale deposits
- Hard-water deposits
- Carbonate scale
- Iron oxide
- Mineral deposits
- Heat exchangers
- Cooling-water circuits
- Chillers
- Condensers
- Cooling coils
- Pumps
- Piping
- Valves
- Tanks
- Process vessels
- Heat-transfer surfaces
- Water circulation systems
Material Compatibility:
| Material | Recommendation |
|---|---|
| SS 304 | Generally suitable |
| SS 304L | Generally suitable |
| SS 316 | Preferred |
| SS 316L | Preferred |
| SS 321 | Suitable after testing |
| SS 347 | Suitable after testing |
| Carbon Steel | Use only for very less time otherwise pitting may occur |
| Mild Steel | Use only for very less time otherwise pitting may occur |
| Cast Iron | Use only for very less time otherwise pitting may occur |
| Copper | Use only for very less time otherwise pitting may occur |
| Brass | Generally avoid |
| Bronze | Testing required |
| Aluminium | Avoid unless specifically validated |
| Aluminium alloys | Alloy-specific testing required |
| Galvanized Steel | Acid attacks zinc coating |
| Zinc | Rapid acid reaction possible |
| Titanium | Generally excellent |
| Hastelloy | Generally suitable |
| Nickel alloys | Alloy-specific confirmation recommended |
| PTFE | Generally suitable |
| PVDF | Generally suitable |
| PVC | Verify temperature |
| PP | Generally suitable |
| HDPE/PE | Generally suitable |
A compatibility chart should not be interpreted as "ECO Safe Descaler can be left indefinitely in the equipment."
For example, stainless steels are generally very resistant to ECO Safe, but temperature and chloride contamination can change the corrosion risk. The British Stainless Steel Association specifically notes that chloride contamination can cause pitting and that higher temperatures may require more corrosion-resistant stainless grades.
ECO Safe Descaler Liquid is considered safe on elastomers like NBR , Buna-N. Note that elastomer contact time and temperature are exrtemely crucial to prevent swelling on gaskets.
Dosage and directions
| Application | Product Concentration |
|---|---|
| Light scale | 5-10% |
| Moderate scale | 10-20% |
| Heavy scale | 20-30% |
| Severe deposits | Up to 100% product |
- Scale thickness
- Scale composition
- Temperature
- Circulation rate
- Cleaning time
- Equipment metallurgy
- Presence of oil/organic contamination
Best Practice to follow for CLEANING SCALE using RXSOL ECO Safe Descaler Liquid
- pH
- Acid concentration
- Iron concentration
- Calcium concentration
- Appearance of solution
- Scale removal
- Corrosion condition
Characteristics and notes
• Automotive - Closed Circuit Cooling, Dynamometers, Extruders, Molders, Radiators, Welders
• Bottling - CO2 Generators, Heaters, Exchangers, Rinse Tanks, Sterilizers, Washers
. HOUSE HOLD - Dissolves hard and old lime scale deposits from your appliances. It extends the life of the appliance and saves running cost. It can be used in appliances such as Washing Machines, Dish Washers, Geysers, Steam Iron, Coffee Makers, Bath Tubs, Bathroom Fixtures etc.
• Buildings - Chillers, Cooling Towers, Pipework
• Chemicals - Dryers, Extruders, Kettles, Mixers, Reactors, Scrubbers, Vacuum Pumps
• Food - Condensers, Ice Machines, Kathabars, Refrigeration Equipment, Steam Tables
• Manufacturing - Chillers, Compressors, Furnaces, Quenchers, Vacuum Pumps
• Metals - Bearings, Castings, Fans, Hearth & Vacuum Furnaces, Shelters, Sprays
• Mining - Bearings, Conveyors, Filters, Presses, Process Lines, Radiators
• Paper- Calendar Mill Rolls, Caustic Lines, Scrubbers, Compressors, Liquor Tanks, Pulverizers, Vacuum Pumps
• Pharmaceutical- Exchangers, Loop Systems, Kathabars, Pumps, Reactors, Stills, Sterilizers
• Refinery - Compressors, Converters, Crackers, Exchangers, Piping, Pumps
• Rubber/Plastics - Banbury Mixers, Calendar & Mill Rolls, Extruders, Injection Molders, Molds, Temperature Control Units, Throat Coolers, Towers, Tubers
• Steel - Bearings, ConCast Units, Generators, Hearths, Spangle Units, Furnaces
• Textile - Air Washers,Compressors, Condensers, Exchangers, Extruders,Towers
Boilers
Condensers
Filters
Heat Exchangers
Kettles & Tanks
Pipelines
Pots
Reactors
Steam Jackets
Bath Rooms and Showers
Metal Processing and much more!
Applications
|
Automotive |
Bottling |
Chemicals |
Food |
|
- Closed Circuit Cooling - Dynamometers - Extruders - Molders - Radiators - Welders |
- CO2 Generators - Heaters - Exchangers - Rinse Tanks - Sterilizers and Washers |
- Dryers - Extruders - Kettles - Mixers - Reactors - Scrubbers - Vacuum Pumps |
- Condensers - Ice Machines - Kathabars - Refrigeration Equipment - Steam Tables |
|
Manufacturing |
Metals |
Mining |
Paper |
|
- Chillers - Compressors - Furnaces - Quenchers - Vacuum Pumps |
- Bearings - Conveyors - Fans - Hearth & Vacuum Furnaces - Shelters - Sprays |
- Bearings - Conveyors - Filters - Presses - Process Lines - Radiators |
- Calendar Rolls - Mill Rolls - Caustic Lines - Scrubbers - Compressors - Liquor Tanks - Pulverizers - Vacuum Pumps |
|
Pharmaceutical |
Refinery |
Rubber & Plastics |
Steel |
|
- Exchangers - Loop Systems - Kathabars - Pumps - Reactors - Stills - Sterilizers |
- Compressors - Converters - Crackers - Exchangers - Piping - Pumps |
- Banbury Mixers - Calendar & Mill Rolls - Extruders - Injection Molders - Molds - Temperature Control - Units - Throat Coolers - Towers and Tubers |
Bearings ConCast Units Generators Hearths Spangle Units Furnaces |
|
Textile |
Utilities |
Other Applications |
|
|
- Air Washers - Compressors - Condensers - Exchangers - Extruders and Towers |
- Boilers - Turbines - Transformers - Cooling Towers - Air Compressors - Hydrogen Coolers - Lube Oil Heat Exchangers |
- Ball Mills - Demisters - Evaporators - Locomotives - Absorption Units - Diesel Generators - Induction Furnaces |
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | ECO Safe Descaler |
| Part Number | RXSOL-37-1048-030 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Mumbai , Chennai, Vizag, Kolkata, UAE , OMAN , CANADA and KENYA
| Phone | +91 22 20871200 - 1400 |
| Fax | +91 22 27612100 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com | |
| Website | www.rxmraine.com |
Proprietory blend of organic acid, corrosion inhibitor and dispersing agents for efficient scale cleaning.
For the full text of the H-Statements mentioned in this Section, see Section 16.
Label elements
| Signal Word | Warning |
| Hazard Statements |
H319 Causes serious eye irritation
H335 May cause respiratory irritation
|
| Precautionary Statements |
Precautionary statements - prevention
P261 Avoid breathing dust/fume/gas/mist/vapours/spray
P280 Wear eye protection/face protection
Precautionary statements - response
P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact
lenses, if present and easy to do. Continue rinsing
P312 Call a POISON CENTER or doctor/physician if you feel unwell
Precautionary statements - storage
P403+P233 Store in a well-ventilated place. Keep container tightly closed
|
| Supplemental Hazard Statements | None |
| Other hazards |
Results of PBT and vPvB assessment
This mixture does not contain any substances that are assessed to be a PBT or a vPvB.
|
| General notes | Take off contaminated clothing. |
| Following inhalation | Provide fresh air. In all cases of doubt, or when symptoms persist, seek medical advice. |
| Following skin contact | Rinse skin with water/shower. In all cases of doubt, or when symptoms persist, seek medical advice. |
| Following eye contact | Rinse skin with water/shower. In all cases of doubt, or when symptoms persist, seek medical advice. |
| Following ingestion | Rinse mouth. Call a doctor if you feel unwell. |
| Most important symptoms and effects, both acute and delayed | Irritation, Cough, Dyspnoea |
| Indication of any immediate medical attention and special treatment needed | None |
| Suitable extinguishing media |
Co-ordinate firefighting measures to the fire surroundings
water spray, alcohol resistant foam, dry extinguishing powder, BC-powder, carbon dioxide (CO₂)
|
| Unsuitable extinguishing media | Water jet |
| Special hazards arising from the substance or mixture | Ingredients of the mixture combustible. The product itself does not burn. |
| Hazardous combustion products | Carbon monoxide (CO), Carbon dioxide (CO₂) |
| Advice for firefighters | In case of fire and/or explosion do not breathe fumes. Fight fire with normal precautions from a reasonable distance. Wear self-contained breathing apparatus. |
Personal precautions, protective equipment and emergency procedures
| For non-emergency personnel |
Avoid contact with skin, eyes and clothes. Do not breathe vapour/spray.
|
| Environmental precautions | Keep away from drains, surface and ground water. The product is an acid. Before discharge into sewage plants the product normally needs to be neutralised. |
| Methods and material for containment and cleaning up | |
| Advice on how to contain a spill | Absorb with liquid-binding material (sand, diatomaceous earth, acid- or universal binding agents). |
| Other information relating to spills and releases | Place in appropriate containers for disposal. |
| Reference to other sections | Hazardous combustion products: see section 5. Personal protective equipment: see section 8. Incompatible materials: see section 10. Disposal considerations: see section 13. |
| Precautions for safe handling | Provision of sufficient ventilation. |
| Advice on general occupational hygiene | Wash hands before breaks and after work. Keep away from food, drink and animal feedingstuffs. |
| Conditions for safe storage, including any incompatibilities |
Keep container tightly closed.
|
| Incompatible substances or mixtures | Observe hints for combined storage |
| Consideration of other advice: | |
| Specific designs for storage rooms or vessels | Recommended storage temperature: 15 – 25 °C |
| Specific end use(s) | No information available. |
| Eye/face protection | Use safety goggle with side protection. |
| Skin protection |
Hand protection
Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374.
For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. The times are approximate values from
measurements at 22 ° C and permanent contact. Increased temperatures due to heated substances, body heat etc. and a reduction of the effective layer thickness by stretching can lead to a considerable reduction of the breakthrough time. If in doubt, contact manufacturer. At an approx. 1.5 times larger / smaller layer thickness, the respective breakthrough time is doubled / halved. The data apply only to the pure substance. When transferred to substance mixtures, they may only be considered as a guide.
Type of material
NBR (Nitrile rubber)
Material thickness
0,11 mm
Breakthrough times of the glove material
480 minutes (permeation: level 6)
Other protection measures
Take recovery periods for skin regeneration. Preventive skin protection (barrier creams/ointments) is recommended.
|
| Respiratory protection |
Respiratory protection necessary at: Aerosol or mist formation. Type: ABEK (combined filters against gases and vapours, colour code: Brown/Grey/Yellow/Green).
|
| Environmental exposure controls | Keep away from drains, surface and ground water. |
| Physical state | Liquid |
| Color | Colorless |
| Odor | Odorless |
| Melting point/freezing point | Not determined |
| Boiling point or initial boiling point and boiling range | ~100 °C at 1,013 hPa |
| Flammability | Non-combustible |
| Lower and upper explosion limit | Not determined |
| Flash point | Not determined |
| Autoignition temperature | Not determined |
| Decomposition temperature | Not relevent |
| pH (value) | 1 - 2 (20 °C) |
| Kinematic viscosity | Not determined |
| Water solubility | Miscible in any proportion |
| Partition coefficient n-octanol/water (log value) | This information is not available |
| Vapour pressure | 23 hPa at 20 °C |
| Density | 1.15-1.24 g /cm³ at 20 °C |
| Relative vapor density | Information on this property is not available |
| Particle characteristics | Not relevant (liquid) |
| Oxidising properties | None |
| Other information | |
| Information with regard to physical hazard classes |
Hazard classes acc. to GHS
(physical hazards): not relevant
|
| Other safety characteristics | |
| Miscibility | Completely miscible with water |
| Reactivity | This material is not reactive under normal ambient conditions. |
| Chemical stability | The material is stable under normal ambient and anticipated storage and handling conditions of temperature and pressure. |
| Possibility of hazardous reactions | Violent reaction with: strong oxidiser, Reducing agents, Metals, Bases |
| Conditions to avoid | There are no specific conditions known which have to be avoided. |
| Incompatible materials | Different metals |
| Hazardous decomposition products | Hazardous combustion products: see section 5. |
| Information on toxicological effects |
Test data are not available for the complete mixture.
|
| Classification procedure | The method for classification of the mixture is based on ingredients of the mixture (additivity formula). |
| Acute toxicity | Shall not be classified as acutely toxic. |
| Skin corrosion/irritation | Shall not be classified as corrosive/irritant to skin |
| Serious eye damage/eye irritation | Causes serious eye irritation. |
| Respiratory or skin sensitisation | Shall not be classified as a respiratory or skin sensitiser. |
| Germ cell mutagenicity | Shall not be classified as germ cell mutagenic |
| Carcinogenicity | Shall not be classified as carcinogenic. |
| Reproductive toxicity | Shall not be classified as a reproductive toxicant |
| Specific target organ toxicity - single exposure | May cause respiratory irritation. |
| Specific target organ toxicity - repeated exposure | Shall not be classified as a specific target organ toxicant (repeated exposure). |
| Aspiration hazard | Shall not be classified as presenting an aspiration hazard. |
| If swallowed |
Data are not available.
|
| If in eyes | Causes serious eye irritation |
| If inhaled | Irritation to respiratory tract, cough, Dyspnoea |
| If on skin | irritant effects, pruritis, localised redness |
| Other information | None |
| Endocrine disrupting properties | None of the ingredients are listed. |
| Toxicity | Shall not be classified as hazardous to the aquatic environment. |
| Biodegradation | Data are not available. |
| Bioaccumulative potential | Data are not available. |
| Mobility in soil | Data are not available. |
| Results of PBT and vPvB assessment | Data are not available. |
| Endocrine disrupting properties | Data are not available. |
| Other adverse effects | Data are not available. |
| Waste Treatment Methods | This material and its container must be disposed of as hazardous waste. Dispose of contents/container in accordance with local/regional/national/international regulations. |
| Sewage disposal-relevant information | Do not empty into drains. |
| Remarks | Waste shall be separated into the categories that can be handled separately by the local or national waste management facilities. Please consider the relevant national or regional provisions. |
| UN number | Not subject to transport regulations |
| UN proper shipping name | Not assigned |
| Transport hazard class(es) | Not assigned |
| Packaging group | Not assigned |
| Environmental hazards | Non-environmentally hazardous acc. to the dangerous goods regulations |
| Special precautions for user | There is no additional information. |
| Transport in bulk according to IMO instruments | The cargo is not intended to be carried in bulk. |
| Information for each of the UN Model Regulations | |
| Transport informationNational regulationsAdditional information(UN RTDG) | Not subject to transport regulations. UN RTDG |
| International Maritime Dangerous Goods Code (IMDG) - Additional information | Not subject to IMDG. |
| International Civil Aviation Organization (ICAO-IATA/DGR) - Additional information | Not subject to ICAO-IATA. |
| Safety, health and environmental regulations/legislation specific for the substance or mixture | There is no additional information. |
| Australian Inventory of Chemical Substances(AICS) | All ingredients are listed or exempt from listing. |
| Other information | Directive 94/33/EC on the protection of young people at work. Observe employment restrictions under the Maternity Protection Directive (92/85/EEC) for expectant or nursing mothers. |
| Chemical Safety Assessment | Chemical safety assessments for substances in this mixture were not carried out. |
| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and weassume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International has been advised of the possibility of such damages. DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable. |
Availability
ECO Safe Descaler Liquid Manufacturer and supplier in Visakhapatnam Vizag Andhrapradesh, Chennai Ennore Tamilnadu, Kolkata Haldia West Bengal, Gandhidham Surat Gujrat, Mumbai Pune Maharastra, Fujairah UAE Middle East, Dubai, Ajman, Abudhabi, Sharjah, Doha Qatar, Sudan, Kuwait, Muscat Barka Sohar Oman, Yemen, Nairobi Kenya Africa