Product Code: RXSOL-40-4097-280
Technical Specification:
| Classification | Chemical Auxiliary Agent |
| CAS No | 1327-41-9 |
| Other Names | Polyaluminium Chloride |
| MF | pac |
| Purity | 30% |
| Type | water treatment chemical |
| Usage | Paper Chemicals, Water Treatment Chemicals |
| Brand Name | RXSOL |
| Model Number | PAC |
| white | Powder |
Packaging & Shipping
Polyaluminium Chloride Packing:de Packing:
25kg/polypropylene woven bags with inner plastic bag, 25kg/PE bag

Product Code: RXSOL-62-5544-4555

Product Code: RXSOL-24-8197-005
| Appearance | Powder |
| Colour | Black |
| Odour | Odourless |
| Boiling Point | 2730 deg C |

Product Code: RXSOL-22-6604-100
Lauric acid, C12H24O2, also known as dodecanoic acid, is a saturated fatty acid with a 12-carbon atom chain. The powdery, white crystalline acid has a slight odor
Lauric Acid is a powerful cleansing agent. It effectively removes dirt, oils, and impurities from the skin, making it an ideal choice for soap intended for cleansing. The combination of cleansing and foaming abilities makes it a preferred ingredient in soaps designed for personal care and cleaning.
Lauric acid is an inexpensive, non-toxic and safe to handle compound often used in laboratory investigations of melting-point depression.

Product Code: RXSOL-19-2505-900
| Appreance | : | Clear Liquid |
| Odour | : | Neutral |
| pH | : | <1.0 |
| Soecific Gravity | : | More than 1 |
| Viscocity | : | 25 cps |
| Boiling Point | : | 108 °C |
| Flash Point | : | Not Applicable |
| Solubility in Water | : |
100 % in any ratio |
How to Cleane Ice Maker Machine?
1st for Ice Maker Component Cleaning: Dip BATH process.
Takes 100 ml of RXSOL Ice Machine Cleaner for 3 Ltr of warm water in plastic container and immerse components in solution. Soak the components until they are free of deposits; for stubborn or thick deposits use a soft brush to help the dissolving action
2nd for Circulation system Cleaning: Recirculation Method.
Use 100 to 150 ml of RXSOL Ice Machine Cleaner in 3 Ltr water in the machine. Allow cleaning solution to circulate for up to 10-20 minutes; it may be necessary to recirculate the solution for longer than 10 minutes to remove heavier and thicker scale deposits. Be sure all distribution and weep holes are clear.
How to Cleane Ice Maker Machine?
1st for Ice Maker Component Cleaning: Dip BATH process.
Takes 100 ml of RXSOL Ice Machine Cleaner for 3 Ltr of warm water in plastic container and immerse components in solution. Soak the components until they are free of deposits; for stubborn or thick deposits use a soft brush to help the dissolving action
2nd for Circulation system Cleaning: Recirculation Method.
Use 100 to 150 ml of RXSOL Ice Machine Cleaner in 3 Ltr water in the machine. Allow cleaning solution to circulate for up to 10-20 minutes; it may be necessary to recirculate the solution for longer than 10 minutes to remove heavier and thicker scale deposits. Be sure all distribution and weep holes are clear.
How Scale formed in Ice Maker Machine?
Dissolved Mineral or presence of mineral present in water is cause of SCALE FORMATION in ICE MAKER. Water tries to freeze in its pure state, while mineral present in water getting precipitate. As the cycle continues and more water is made into ice, the minerals over concentrate and eventually precipitate as a lime scale deposit.
Why Regular Cleaning of SCALE is essential from Ice Maker?

Product Code: RXSOL-15-2505-005
| Appreance | : | Clear Liquid |
| Odour | : | Neutral |
| pH | : | <1.0 |
| Soecific Gravity | : | 1.3-1.1.35 |
| Viscocity | : | 25 cps |
| Boiling Point | : | 108 °C |
| Flash Point | : | Not Applicable |
| Solubility in Water | : |
100 % in any ratio |

Product Code: RXSOL-34-1503-210

Product Code: RXSOL-23-2901-035
Technical Data
|
Form |
Liquid |
| Colour | Clear to Light Amber |
| Density | 1.38 |
| pH | <1.0 |
| Freezing Point | -45°C |
| Compatibility Materials | N, Hypalon, Neoprene, Polyethylene, Polypropylene, Polyurethane, PVC, Teflon, Vinyl, Viton. |
| Not compatible | Aluminium, Brass, Carbon Steel, Nickel, Stainless Steel 304/316, Plasite 4005/6000 and 7122 |
| Water solubility | Soluble |
Corroision Inhibitor for METAL is a liquid film-forming corrosion inhibitor. For use in ballast tanks, bilges, voids, cofferdams and barges. It is a blend of organic and inorganic inhibitors. It contains no chromates and is completely soluble in sea water.

Product Code: RXSOL-43-4028-220

Product Code: RXSOL-96-1193-025

Product Code: RXSOL-42-5005-025
We carry a complete line of condensate treatment chemicals. Condensate treatment chemicals are used to increase the condensate pH, thus reducing corrosion to the entire boiler steam system. The most common product is a tri-blend amine of cyclohexylamine, morpholine, and diethylaminoethanol (DEAE) neutralizing amines, although we do have standard RXSOL products or we can custom blend to your needs.
RXSOL-50-5005-DCM1 10% DEAE, 10% Cyclo, 10% Morpholine
RXSOL-50-5005-DCM2 20% DEAE, 20% Cyclo, 20% Morpholine
RXSOL-50-5005-C 20% Cyclohexylamine
RXSOL-50-5005-D 20% DEAE
RXSOL-50-5005-M 20% Morpholine
RXSOL-50-5005-C5 50% Cyclohexylamine
RXSOL-50-5005-D 50% DEAE
RXSOL-50-5005-M5 50% Morpholine
RXSOL-50-5005-025 alkaline and the vapors are irritating to eyes and lungs. Avoid contact with eyes and skin. Do not take internally. Observe safety regulations wear Goggles, PVC gloves and Apron when handling Provide ample ventilation Avoid contact with skin in case of contacts wash with cupious amount of water immediately. If eyes are splashed give immediate and prolonged irrigation with clean running water and obtain medical attention.
Not for internal use :-
If swallowed do not induce vomiting give plenty of water or milk and call a doctor immediately.
Packing. GENERAL REMARKS:-Do not store RXSOL-50-5005-025 near a heating equipment.

Product Code: RXSOL-42-5005-200
We carry a complete line of condensate treatment chemicals. Condensate treatment chemicals are used to increase the condensate pH, thus reducing corrosion to the entire boiler steam system. The most common product is a tri-blend amine of cyclohexylamine, morpholine, and diethylaminoethanol (DEAE) neutralizing amines, although we do have standard RXSOL products or we can custom blend to your needs.
RXSOL-50-5005-DCM1 10% DEAE, 10% Cyclo, 10% Morpholine
RXSOL-50-5005-DCM2 20% DEAE, 20% Cyclo, 20% Morpholine
RXSOL-50-5005-C 20% Cyclohexylamine
RXSOL-50-5005-D 20% DEAE
RXSOL-50-5005-M 20% Morpholine
RXSOL-50-5005-C5 50% Cyclohexylamine
RXSOL-50-5005-D 50% DEAE
RXSOL-50-5005-M5 50% Morpholine
RXSOL-50-5005-025 alkaline and the vapors are irritating to eyes and lungs. Avoid contact with eyes and skin. Do not take internally. Observe safety regulations wear Goggles, PVC gloves and Apron when handling Provide ample ventilation Avoid contact with skin in case of contacts wash with cupious amount of water immediately. If eyes are splashed give immediate and prolonged irrigation with clean running water and obtain medical attention.
Not for internal use :-
If swallowed do not induce vomiting give plenty of water or milk and call a doctor immediately.
Packing. GENERAL REMARKS:-Do not store RXSOL-50-5005-025 near a heating equipment.