RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,061 products across 71 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Corrosion Inhibitor

Marine & Ship Care

RXSOL corrosion inhibitors are grouped by where the corrosion happens. During acid cleaning: Acid Corrosion Inhibitor RXSOL 213 and Corrosion Inhibitor for Citric Acid, added to hydrochloric, sulphamic or citric acid so the acid attacks scale and not steel. In cooling and closed systems: Corrosion Inhibitor for Multi Metal Cooling Water, Corrosion Inhibitor Closed Open Cooling Water System, RXSOL 4000 (nitrite-borate), with cyclohexylamine for condensate. In process and oilfield streams: Corrosion Inhibitor Carbon Dioxide and H2S (filming amine), Hydrotech 3670 RX for hydrotest water and lay-up. On bare metal: Corrosion Inhibitor for Metal Rust Preventive (dewatering and film-forming fluids). Also listed: oxygen scavengers and vanadium pentoxide used in inhibitor and catalyst formulations.

Dosing is in ppm or percent of the fluid treated, with contact time and the film-persistence test where relevant; packs 5, 25 and 210 litres.

Frequently asked questions

How much inhibitor do I add to 10% hydrochloric acid for descaling?

Typically 0.1–0.3% of Acid Corrosion Inhibitor RXSOL 213 by volume of the diluted acid; the page lists the ratio for each acid and temperature.

Which inhibitor for hydrotest water?

Hydrotech 3670 RX, dosed per cubic metre of test water, with an oxygen scavenger for long lay-ups.

Is there a vapour-phase inhibitor for enclosed spaces?

Rust-preventive and VCI-type products are listed under Rust Clean & Protect; ask for the lay-up data sheet.

What does RXSOL 4000 do?

It is a nitrite-based closed-system inhibitor for engine jackets and chilled-water loops, maintained at 1,000–2,400 ppm nitrite.