Power Plant / Heavy Industries
Water Treatment
Thermal and captive power plants buy chemicals in three phases: commissioning and pre-operational cleaning, steady-state water and fuel treatment, and outage cleaning. RXSOL supplies each. Commissioning: Commissioning Cleanser for boiler and pipework degreasing, Corrosion Inhibitor Pretreatment Filming Agent, Catalyzed Hydrazine Hydrate 35% for passivation and oxygen scavenging. Operation: Coagulant Clear AL for raw-water clarification, sodium thiosulphate for dechlorination, Sodium Silicate Neutral and silicate-based inhibitors, Corrosion Inhibitor for metal Rust Preventive for spares and lay-up. Outage: Thermic Fluid Decarbonizer for heat-transfer-oil systems, Alkaline Foam Cleaner for condensers and coolers, Enviro Coil Acid for fin-tube coils, RXSOL 666 Surface Clean for turbine casings and Veg Soft Soap for general degreasing.
Pages give the concentration, circulation temperature and time, and disposal/neutralisation notes required by plant chemists for a cleaning procedure.
Frequently asked questions
What is used for pre-commissioning alkaline boil-out?
Commissioning Cleanser (alkaline degreaser) at the stated percentage, boiled out for 24–48 hours, followed by acid cleaning and passivation with catalysed hydrazine.
Do you supply hydrazine hydrate in 35%, 50% and 80%?
Yes — all three grades, with catalysed 35% for faster oxygen scavenging.
Which product cleans a thermic-fluid (hot-oil) system?
Thermic Fluid Decarbonizer circulated hot to dissolve carbon and sludge before the oil change.
Can you supply tender quantities?
Yes — plant and tender quantities are quoted from Navi Mumbai with delivery across India.
No products found