pH Booster Morpholine Base

Size:

Color:

Product Short Description: RXSOL pH Boosters are morpholine based alkaline formulation,used as alkalinity source for boiler feed water. It is synergized with properties of pH boosting and water conditioning.
Product Technical Specification:

 

Properties Unit Typical Value
Form and Appearance - Clear Colorless Liquid
Odor - Characteristic
pH (neat) pH Alkaline
Solubility - Completely Soluble in Water
Remarks:

STORAGE & HANDLING

pH booster should be stored in an air tight container away from direct heat.
Always store at cool & dry place.
Handle using goggles & do not breathe in the vapours.
Wash thoroughly in case of contact. Do not swallow.

 

pH Control

Maintenance of proper pH throughout the boiler feedwater, boiler, and condensate systems is essential for corrosion control. Most low-pressure boiler system operators monitor boiler water alkalinity because it correlates very closely with pH, while most feedwater, condensate, and high-pressure boiler water requires direct monitoring of pH. Control of pH is important for the following reasons:

  • corrosion rates of metals used in boiler systems are sensitive to variations in pH
  • low pH or insufficient alkalinity can result in corrosive acidic attack
  • high pH or excess alkalinity can result in caustic gouging/cracking and foaming, with resultant carryover
  • speed of oxygen scavenging reactions is highly dependent on pH levels

The pH or alkalinity level maintained in a boiler system depends on many factors, such as sys-tem pressure, system metals, feedwater quality, and type of chemical treatment applied.

The corrosion rate of carbon steel at feedwater temperatures approaches a minimum value in the pH range of 9.2-9.6 . It is important to monitor the feedwater system for corrosion by means of iron and copper testing. For systems with sodium zeolite or hot lime softened makeup, pH adjustment may not be necessary. In systems that use deionized water makeup, small amounts of caustic soda or neutralizing amines, such as morpholine and cyclohexylamine, can be used.

In the boiler, either high or low pH increases the corrosion rates of mild steelThe pH or alkalinity that is maintained depends on the pressure, makeup water characteristics, chemical treatment, and other factors specific to the system.

The best pH for protection of copper alloys is somewhat lower than the optimum level for carbon steel. For systems that contain both metals, the condensate and feedwater pH is often maintained between 8.8 and 9.2 for corrosion protection of both metals. The optimum pH varies from system to system and depends on many factors, including the alloy used 

To elevate pH, neutralizing amines should be used instead of ammonia, which (especially in the presence of oxygen) accelerates copper alloy corrosion rates. Also, amines form protective films on copper oxide surfaces that inhibit corrosion.

Images: Alt



Oxytreat Scavanger Plus 210 Ltr

Size:

Color:

Product Short Description: Oxygen Scavenger Plus is a catalysed liquid solution of Hydrazine and diethylhydroxylamine (DEHA). Its volatile properties ensure distribution throughout the boiler and condensate system, and hence protects against oxygen corrosion in all parts of the sy
Product Technical Specification:

 

Product Specifications:

Density 

1

Packing, Type

PLASTIC

Volume

25 l

pH

10.5

Colour 

LIGHT YELLOW

Appearance

LIQUID

Directions for use
This product is formulated for use in conjunction.Oxygen Scavenger Plus can be used in any boiler system, and in conjunction with mechanical deaeration systems. Removal of dissolved oxygen is vital for prevention of corrosion and especially pitting corrosion in boilers. When dosed into a boiler system, Oxygen Scavenger Plus will react with dissolved oxygen and form non corrosive compounds. The product is volatile, and left over product from oxygen scavenging in the pre-boiler section will evaporate and assist protection of the steam and condensate system. No solid materials are produced when using Oxygen Scavenger Plus.
 

Dosing method
Rx Marine International recommends continuously into the boiler feed line and Boiler Water Treatment Dosing Unit.
Dosing should be controlled so that the DEHA residual in the condensate is between 0.08-0,30 ppm. The consumption will depend on feed water temperature and the amount of water fed into the boiler. For more information about initial dosage and dose rate please consult your nearest Customer Centre.
Test result condensate PPM DEHA   
0.00 - 0.08 0.08 - 0.30 0.30 +
Increase dose 25% Maintain dose Decrease dose 25%

Sampling and testing
A representative sample of Condensate should be drawn for analysis daily. The sample should always be taken from the same sampling point, cooled and tested immediately By Rxsol Test Kit. It is important that regular testing is carried out, to ensure the correct level of treatment is maintained.
 

Features
• Fast acting, liquid oxygen scavenger.
• Safe and easy to use, low toxicity.
• Reduces corrosion of iron and copper, increasing system life and reliability.
• Neutralises acids occurring in condensate system.
• Volatile product, provides distribution and protection throughout the boiler system, economical in use.
• Suitable for use in conjunction with combined and co-ordinated treatment programmes.
• Organic product, no dissolved solids added.
• Simple test to determine treatment level. 

Remarks:

The establishment of protective metal oxide lay-ers through the use of reducing agents (such as hydrazine, hydroquinone, and other oxygen scavengers) is known as metal passivation or metal conditioning. Although "metal passivation" refers to the direct reaction of the compound with the metal oxide and "metal conditioning" more broadly refers to the promotion of a protective surface, the two terms are frequently used interchangeably.

The reaction of hydrazine and hydroquinone, which leads to the passivation of iron-based metals, proceeds according to the following reactions:

N2H4 6Fe2O3 ® 4Fe3O4 2H2 N2
hydrazine    hematite    magnetite    water    nitrogen

 

C6H4(OH)2 + 3Fe2O3 ® 2Fe3O4 + C6H4O2 + H2O
hydroquinone   hematite   magnetite   benzoquinone   water

 

Similar reactions occur with copper-based metals:

N2H4 + 4CuO ® 2Cu2O + 2H2O + N2
hydrazine   cupric oxide   cuprous oxide   water   nitrogen

 

C6H6O2 + 2CuO ® Cu2O + C6H4O2 + H2O
hydroquinone   cupric oxide   cuprous oxide   benzoquinone   water

 

Magnetite and cuprous oxide form protective films on the metal surface. Because these oxides are formed under reducing conditions, removal of the dissolved oxygen from boiler feedwater and condensate promotes their formation. The effective application of oxygen scavengers indirectly leads to passivated metal surfaces and less metal oxide transport to the boiler whether or not the scavenger reacts directly with the metal surface.

A significant reduction in feedwater oxygen and metal oxides can occur with proper application of oxygen scavengers.

Images: Alt



Diethyl Hydroxyl Amine N,N- DEHA

Size:

Color:

Product Short Description: A colourless to pale yellow transparent liquid, available as 98% DEHA and also as 85% solution in water.
Product Technical Specification:

Physical Properties

Empirical Formula   C4H11NO
Molecular Wt   89.1
  DEHA 98% DEHA 85%
Sp. Gr. at 20°C  0.855 - 0.875 0.895 - 0.905
Refractive Index 1.418 - 1.420 1.418 - 1.420
Boiling Point 124 to 126°C 94 to 96°C
Freezing Point -25 to -27°C Below 0°C
Flash Point (Closed C) Below 45°C 45 to 47°C
Solubility in water Soluble Soluble
pH 10.2 10

 Specification :

Specification DEHA 98% DEHA 85%
Purity as DEHA (wt. %) 98.00 min.   85.00 min.
Water Content (% by wt.)   -- 15.00 max
Ethylamines (% by wt.) 0.5 max. 0.05 max.
Remarks:

Diethylhydroxylamine (DEHA) is an organic compound with the formula (C2H5)2NOH. It is a colorless liquid, although it is usually encountered as a solution. It is mainly used as an oxygen scavenger in water treatment. It is a volatile oxygen scavenger and reacts in a ratio of 2.8/1 DEHA/O2. It is employed in high pressure (>70 bar) boiler systems due to a very low rate of reaction at low temperatures and pressures. Due to its volatility, it acts as an oxygen scavenger throughout the entire boiler system due to steam carryover. DEHA also reacts with ferrous metals to form a passivized film of magnetite throughout the boiler system.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Xylene AR reagent

Size:

Color:

Product Short Description: Xylene analar reagent grade for oil, Scale Composition tests, metering operations.
Product Technical Specification:

XYLENE ANALAR,2.5LTR

Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



BOILPLEX AT Hardness Control

Size:

Color:

Product Short Description: In addition to controlling the alkali content, scale and sediment, Boilplex ATprotects the condensate system (Steam superheater) from corrosion caused by low pH. Boilplex AT control sludge and sediment deposition by adsorption on sludge boiler surfaces, Particles are soft, do not stick together
Product Technical Specification:

 

Appearance

: Clear liquid

Specific gravity at 25 º C (77 º F)

: 1.056

Fire

: off

Freezing temperature

: -6.6 º C (20 º F)

pH

: 13.4

Stability after freeze / that

: yes

Remarks:

Did you know, how to keep BOILER water CLEAR and Sludge free?

RXSOL BOILPLEX AT Phosphate and synthetic polymer Based Boiler water treatment chemicals to control sludge for low and medium pressure Boilers which results in the clean boiler water. USES of RXSOL BOILPLEX AT Hardness Control provide tolerance of feedwater quality fluctuations.

Chemically one part of The polymers used in BOILPLEX AT  keeping the sludge particles soft by increasing property of nonadherent which also resulting smooth blowdown during boiler cleaning and maintenance operation.


While Other part of Phosphate which is used in BOILPLEX AT serve as deposit control agents by Iron dispersancy, main cause of sequestering deposits.

USES of RXSOL BOILPLEX AT boiler water treatment, can help BOILER WATER CLEAN and CLEAR.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Potassium Chromate

Size:

Color:

Product Short Description: Potassium Chromate Pure indicator for determination of Chloride by titration method.
Product Technical Specification:
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Antiscalant Boiler

Size:

Color:

Product Short Description: Antiscalant for Boiler Water Units , specially designed to control the development of scale in water plants.
Product Technical Specification:
 
Appearance Clear, Yellowish Amber Liquid
Flash point Non-flammable
Solubility in water Soluble in all proportions
Freezing Point -15 Degree

General Specification :-

Gloves and goggles should be worn as a precaution when handling the concentrated solution. (See Material Safety Data Sheets for further information)

Remarks:

SAFETY INFORMATION:

Gloves and goggles should be worn as a precaution when handling the concentrated solution. (See Material Safety Data Sheets for further information).
Antiscalant Boiler  is compatible with carbon steel and other commonly used materials of construction. Observe all safety precautions shown in the material safety data sheet, available on request.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Antiscalant ORG EV 2030

Size:

Color:

Product Short Description: High performance liquid product for the control of scaling and particulate fouling in seawater multi-stage flash distillation plants. It is a multifunctional product based on polycarboxylic acid chemistry.
Product Technical Specification:

 

Appearance   Liquid
Colour   Clear Amber
pH   8.0-9.0
Solids content    37 to 43% w/w
specific gravity at 20oC    1.25 to 1.30
Boiling point range   100 to 102 oC
 Freezing point range    0 to -10 oC

Tranortation : 

Not Claasified as Hazardouce.
Classification non-hazardous for conveyance

Packing : 250 Kgs Drum.

Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



SODIUM SULPHIDE solution

Size:

Color:

Product Short Description: Colourless water-soluble salts that give strongly alkaline solutions
Product Technical Specification:
Remarks:

The solution of Sodium Sulphide obtained from the process is concentrated to 10-12% and is available at different percentages in tanker loads. In Industries Na2S is produced by carbothermic reduction of sodium sulfate often using coal. It is used in the production of rubber chemicals, sulfur dyes and other chemical compounds. It is used in other applications including ore flotation, oil recovery, making dyes, and detergent.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Boiler Hydrocarbon Oil Sludge Remover

Size:

Color:

Product Short Description: Boiler Hydrocarbon Sludge Remover is a product to be used in situations where the boiler water is contaminated with oil. This high performance product is applicable to both medium and low–pressure steam boilers in order to prevent sludge deposits.
Product Technical Specification:
Remarks:
Images: Alt