Buffer Cleaner
Oman Chemical is leading one Largest Supplier, Manufacture a
Product Code: RXSOL-42-4029-025
| Appearance | Paly Yellow, Clear liquid |
| Density | 1.01-1.1 |
| Boiling Poitnt | 100 degree celcius |
| pH | Alkaline |
| Not Compatible | : Aluminium, Copper, Copper Alloys, Nickel, Neoprene, Polyurethane. |
|---|
Frequently Asked Questions about Boiler treatment
Answer:
A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.
Answer:
Choosing the right inhibitor depends on:
Boiler pressure and temperature
Feedwater quality (e.g., hardness, pH, oxygen content)
Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)
Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).
Answer:
The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Product Code: RXSOL-11-1048-050
Typical descaling cleaning procedure :
1st Stage : Take ‘RXSOL-11-1053-010’ weblink ( http://rxmarine.com/Alkaline-Descaler ) and mix with water in the ratio of 1:6 (One litre of RXSOL-1053 and six litres of water). Circulate the solution or immerse the equipment in this solution for 2 hrs. This will be helpful in loosening the hard deposited scale.
RXSOL-40-1048-025 should not be used on Aluminium, Zinc, Tin, or any Galvanized Surfaces for which a special grade cleaner should be used. Chemical Cleaning Module Rx cleansers has developed a 280 litres capacity cleaning module, primarily designed for use with chemical acid solvents for descaling boilers, calorifiers, heat exchangers & other types of equipment where rust & scale form RXSOL-11-1008--DC Boilers, See Rx cleansers Practical Application Manual.
Formation of Calcium Sulfate is main cause for SCALE formation :::
The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation. Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously. There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.
In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices. The low hardness levels largely preclude calcium sulfate boiler scale. By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal. Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated. Calcium sulfate scale deposition can result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals. Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger.
Sulfate content can be calculated in Laboratory by using this method ::: http://rxmarine.com/SULFATE-TEST-KIT

Product Code: RXSOL-42-1524-030
| Solubility (10 % Aquous Soln) | V. S. Hazy to clear solution. |
| pH Value of 5% Solution | 3.5 to 4.5 |
| Specific Gravity @ 25° C | 1.310 – 1.370 |
| Density, lbs/gal @ 25° C | 10.9 - 11.3 |
| Description | Oxygen Scavenger for Boiler |
| Standard Packing | 30 Kg / 50 Kg. / 250 kg HM HDPE Barrel |
The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.
Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.
The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.
The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation
It is used to arrest oxygen in sea water
It removes Entrapped Oxygen and thus reduces Corrosion
In Oil Drilling Chemicals

Product Code: RXSOL-42-6141-051
Product Name : Zinc Chloride Liquid (Lye)
CAS No. 7646-85-7
|
Specifications |
Zinc Chloride Liquid (Lye) |
|
Assay (as ZnCI2) |
70% |
|
Appearance |
Water white liquid |
|
pH Value |
4.6-5.5 |
|
Iron & Lead |
Less than 10 ppm |
|
Specific Gravity |
1.40-1.45 |
|
Sulphates |
200 ppm max |
|
Ammonium |
400 ppm max |
|
Solubility |
Very soluble in water, freely soluble in ethanol (96 per cent) and in Glycerol. |

Product Code: RXSOL-42-1304-025
|
Appearance |
Yellowish Powder |
|
Density |
in g/cm3 at 15°C: 1.2 |
|
Flash Point |
(PMCC) in °C: N/A |
|
pH |
in 10 wt-%: 1.1 |
|
Compatibility |
|
|
Metal |
Avoid Aluminium, Zinc, Tin and their alloys and Galvanised surfaces. |
|
Rubber |
No known effect. |
RXSOL DESCALE POWDER is chemical compound and should be handle with all chemicals handling precaution like use chemical protective goggle, Hand gloves etc... For more details pl. refer RXSOL product MSDS.

Product Code: RXSOL-19-4060-025
| Appearance | Yellow Solution |
| Active Content | 14% Min. |
| Ratio of CMI to MI | 2.5-4.0 |
| pH | 2.0 - 5.0 |
| Density | 1.26-1.33 |
| Stability | Stable for 1 year at 25℃ |
| Category | Biocide/ Algaecide/ Disinfectant/ Bactericide |

Product Code: RXSOL-42-4008-020
Appearance Clear, colorless liquid
Physical State Liquid
Color Colorless
Odor Characteristic Odor
Odor threshold Not applicable
pH <= 3.7
Melting point/freezing point -22 °C
Boiling Point/Range 105 °C
Flash point Not flammable
Evaporation Rate No information available
Flammability (solid, gas) Not flammable
Flammability Limit in Air Not applicable
Upper flammability limit:
Lower flammability limit:
Vapor pressure 26 mm Hg @ 30 °C
Vapor density No information available
Density 1.10 g/cm³ @ 20ºC
Specific gravity 1.10
Water solubility completely soluble
Solubility in other solvents No information available
Partition coefficient log Kow = -1.5 @ 20 °C
Autoignition temperature Not combustible
Decomposition temperature 100 °C
Viscosity, kinematic 1.06 cP @ 20 °C
Viscosity, dynamic No information available
Explosive properties No information available
Oxidizing properties Strong oxidizer
Molecular weight 34
Bulk density Not applicable

Product Code: RXSOL-42-1519-500
Standardized at 25°C against chemicals whose certification is traceable to NIST.
Formula: C₁₀H₁₄N₂Na₂O₈·2H₂O
MW: 372.24 g/mol
Melting Point: 255 °C
Storage Temperature: Ambient
CAS Number: 6381-92-6
EINECS: 205-358-3

Product Code: RXSOL-42-6168-025
EDTA is most commonly used to determine hardness (i.e., Calcium and Magnesium ions) in water, where the pH must be approximately 10 and is usually controlled by adding a buffer such as Water Hardness Buffer. Water Hardness Indicator (Eriochrome Black T), Eriochrome Blue Black R, Calmagite, and Murexide are used for hardness or Calcium determinations using EDTA.
EDTA cas no : 6381-92-6
EDTA chemical Formula : [(HO2CCH2-)(NaO2CCH2-)N-CH2]2·2H2O

Product Code: RXSOL-42-6141-050
|
Physical state and appearance |
Snow White Solid. |
|
Odor |
Odorless. |
|
Taste |
Not available. |
|
Molecular Weight |
136.29 g/mole |
|
Color |
White. |
|
Assay % |
Refer below for various grade |
|
Boiling Point |
732°C (1349.6°F) |
|
Melting Point |
290°C (554°F) |
|
Critical Temperature |
Not available. |
|
Specific Gravity |
2.907 (Water = 1) |
|
Vapor Pressure |
Not applicable. |
|
Vapor Density |
4.7 (Air = 1) |
|
Volatility |
Not available. |
|
Odor Threshold |
Not available. |
|
Water/Oil Dist. Coeff. |
Not available. |
|
Ionicity (in Water) |
Not available. |
|
Dispersion Properties |
See solubility in water. |
|
Solubility |
See solubility in water. |
| PARTICULARS | H.P. GRADE | TECHNICAL | COMMERCIAL | SOLUTION |
| ASSAY (%) | 98-99 | 90-92 | 80-85 | APCR |
| APPEARANCE | SNOW WHITE | SNOW WHITE | SNOW WHITE | CLEAR SOLUTION |
| AMMONIA (AS NH4CL) % | < 1 | < 5 | 10-15 | APCR |
| ALKALIES & ALKALINE EARTH (%) | < 1 | < 1.5 | APCR | APCR |
| IRON (PPM ) | < 10 | < 15 | < 15 | < 15 |
| LEAD (PPM ) | < 10 | < 15 | APCR | APCR |
| NICKLE (PPM) | < 2 | < 2 | APCR | APCR |
| COPPER (PPM) | < 2 | < 2 | APCR | APCR |
| COBALT (PPM) | < 2 | < 2 | APCR |
APCR |
Use of the Zinc Chloride are Following :
Fluxes :
The property to attack metal oxide and salts from metal surface and gives good metal to metal bonding make Zinc Chloride a better raw material for fluxes.
________________________________
Dry Cell Batteries :
Zinc Chloride is used in Dry Cell Batteries as an electrolyte and also as a moisture absorbent and corrosion inhibitor.
________________________________
Glue :
It is used in manufacture of Glue, Paper, Cosmetics, Synthetic, Fibers, Disinfectants and Fire Fitting form.
________________________________
Electro Plating :
It is one of the main raw material for manufacturing of electroplating chemicals.
________________________________
Wood Preservative :
It is also a good preservative.
________________________________
Water treatment Chemicals :
It is using in water treatment because of corrosion inhibitor property.
________________________________
Catalysts :
Zinc Chloride is used as a catalyst in production of methylene chloride from methyl alcohol.
________________________________
Petroleum :
It is used to separate water from oil as it is a good emulsion breaker. It is also used in oil and gas wells.
________________________________
Rubber Vulcanization :
It is used as accelerator in the vulcanizing process of rubber.
________________________________
Anteseptic AND Deodorant Preparation :
Zinc Chloride is also used to prepare antiseptics and deodorants.
________________________________
Textile Finishing :
Zinc chloride is a more active catalyst than magnesium chloride and almost as active as zinc nitrate. It does not contribute to resin yellowing on white goods and has little effect on dye shades in tinted materials. The textile grade is used as a catalyst in resin systems that impart a durable-press or wash and wear finish to cotton and cotton synthetic blend fabrics. Zinc Chloride 50% Solution also serves as a high quality mercerizing agent for cotton.
________________________________
Raw Material & Other Chemicals :
Zinc Chloride is an excellent source of zinc and used as a raw material for the production of other zinc chemicals.