Buffer Cleaner
Oman Chemical is leading one Largest Supplier, Manufacture a
CHARACTERISTIC :
Appearance | Clear Solution |
Odour | Characteristic |
pH | 5-6 |
Density | >1.2 |
Sampling And Testing
A sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Rxsol Hardness Test Kit instructions and fill the Boiler Water Log Form according to result results. It is important that regular testing is carried out to ensure levels of treatment are correct.
Physical Properties :
Appearance :White powder
Corrosive action :NonE
pH 1% solution :8.8
Flash point :None
Phosphate/pH relationship recommended to control boiler corrosion. Different forms of phosphate consume or add caustic as the phosphate shifts to the proper form. For example, addition of monosodium phosphate consumes caustic as it reacts with caustic to form disodium phosphate in the boiler water according to the following reaction:
NaH2PO4 | + | NaOH | ® | Na2HPO4 | + | H2O |
monosodium phosphate | sodium hydroxide | disodium phosphate | water |
Conversely, addition of trisodium phosphate adds caustic, increasing boiler water pH:
Na3PO4 | + | H2O | ® | Na2HPO4 | + | NaOH |
trisodium phosphate | water | disodium phosphate |
sodium hydroxide |
This is a white high molecular weight solution. It is hydrophilic and of low causticity.
Appearance / Color : White, viscous liquid
Our others valauable Products :
BOILER TREAT ONE SHOT
Combined Boiler Water Conditioner
A one-product treatment for all auxiliary boilers including waste heat, and exhaust gas boilers. it prevents scale formation, inhibits corrosion and conditions sludge.
HARDNESS CONTROL
Boiler Water Conditioner
Added to the boiler water to maintain optimum phosphate level, which prevents calcium and magnesium hardness salts formation. The precipitate can be removed by blow-down.
ALKALINITY CONTROL
Boiler Water Conditioner
Added to the boiler water to maintain optimum alkalinity level to prevent corrosion. Due to this, Ca and Mg hardness salts cannot form and the precipitate is removed by blow-down.
HYDRAZIDE
Oxygen Scavenger
Used for rapid removal of oxygen in boiler feed water and condensate systems, which prevents corrosion. It is the alternative for hazardous and potentially carcinogenic products.
BOILER TREAT COMBI
Organic Boiler Water Treatment
Special blended low molecular weight compounds that elevate boiler water pH to levels, which reduce corrosion. It also prevents under deposit corrosion caused by excess alkalinity.
LIQUID COAGULANT
Oil and Sludge Conditioner
Used to prevent formation of adherent deposits and sticky sludge in boilers,which are then removed by normal blow-down. It can also be used in the event of an oil contamination.
CONDENSATE CONTROL
Steam and Condensate Conditioner
Injected into the condensate pump to prevent corrosion in steam and condensate lines.It’s also used to protect idle boilers from corrosion. It neutralizes acidic conditions in condensate systems and volatilizes with steam.
COOL WATER TREAT NCLT
Corrosion and Scale Inhibitor
Provides an effective anodic inhibitor treatment and protects ferrous and non-ferrous metals. It deposits a microscopic protective film on surfaces and has built-in pH buffering compounds. It controls formation of hard scale deposits.
EVEPORATOR TREAT
Prevention of scale in Evaporators
Used in both high and low pressure evaporators to prevent foaming, carry-over and scale formation. It’s safe to use where distillate is used for drinking purposes. It prevents scale formation and avoids the need for acid descaling.
Appearance: Clear, viscous liquid
Specific Gravity at 25° C (77° F): 1.0
pH: 6.9 - 10
RXSOL-50-5003-025 eliminate light oil contamination, A concentrated solution of surface-active polymers which is use as an internal sludge conditioners in boilers. Boiler Coagulant is a colorless, high molecular weight solution used in both medium and low-pressure boilers (<850 psig or 60 kg/cm2)
Sampling And Testing
A sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Fill the Boiler Water Log Form according to result. It is important that regular testing is carried out to ensure levels of treatment are correct.
Physical Properties :
Appearance :Liquid
Corrosive action :None
pH 1% solution :8.8
Flash point :None
Phosphate/pH relationship recommended to control boiler corrosion. Different forms of phosphate consume or add caustic as the phosphate shifts to the proper form. For example, addition of monosodium phosphate consumes caustic as it reacts with caustic to form disodium phosphate in the boiler water according to the following reaction:
NaH2PO4 | + | NaOH | -> | Na2HPO4 | + | H2O |
monosodium phosphate | sodium hydroxide | disodium phosphate | water |
Conversely, addition of trisodium phosphate adds caustic, increasing boiler water pH:
Na3PO4 | + | H2O | -> | Na2HPO4 | + | NaOH |
trisodium phosphate | water | disodium phosphate |
sodium hydroxide |