RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,082 products across 97 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Solvent Chemicals

1,2-DIMETHOXYETHANE

Part number
RXSOL-19-1164-190
Brand
RXSOL
RXSOL

Applications

1,2-Dimethoxyethane is a solvent used in the formation of alikalai metal-hydro-carbon adducts

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name 1,2-DIMETHOXYETHANE
Part Number RXSOL-19-1164-190

Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.

VASHI ,NEW BOMBAY 400703 INDIA

Branch : Kandla,  Hazira,  Chennai,  Vizag, Paradip, Kolkata, UAE, OMAN, CANADA , OMAN

Phone +91 22 20871200 - 1400
Fax +91 22 27612100 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
Website www.rxmarine.com
Name     of        Substance                          Cas Number EC-No. Weight %  CLP Classification - Regulation (EC) No
1,2-DIMETHOXYETHANE 110-71-4 EEC No. 203-794-9 >95 Flam. Liq. 2 (H225)
Acute Tox. 4 (H332)
Repr. 1B (H360FD)
Skin Irrit. 2 (H315)
[EUH019]

 

Environmental hazards Based on available data, the classification criteria are not met
Hazard Statements          H225 - Highly flammable liquid and vapor
H332 - Harmful if inhaled
H315 - Causes skin irritation
H360FD - May damage fertility. May damage the unborn child
EUH019 - May form explosive peroxides
Precautionary Statements P210 - Keep away from heat/sparks/open flames/hot surfaces. - No smoking
P304 + P340 - IF INHALED: Remove to fresh air and keep at rest in a position comfortable for breathing
P312 - Call a POISON CENTER or doctor/ physician if you feel unwell
P302 + P352 - IF ON SKIN: Wash with plenty of soap and water
P280 - Wear protective gloves/ protective clothing/ eye protection/ face protection
Additional EU labelling Restricted to professional users.
General Advice Show this safety data sheet to the doctor in attendance. Immediate medical attention is required.
Eye Contact Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Immediate medical attention is required.
Skin Contact Wash off immediately with plenty of water for at least 15 minutes. Immediate medical attention is required.
Inhalation:              Move to fresh air. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Immediate medical attention is required. If not breathing, give artificial respiration.
Ingestion: Do not induce vomiting. Call a physician or Poison Control Center immediately.
Self-Protection of the First Aider Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and prevent spread of contamination.
Most important symptoms and effects, both acute and delayed Breathing difficulties. Inhalation of high vapor concentrations may cause symptoms like headache, dizziness, tiredness, nausea and vomiting
Indication of any immediate medical attention and special treatment needed Notes to Physician Treat symptomatically.

Suitable extinguishing media Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Cool closed containers exposed to fire with water spray.
Extinguishing media which must not be used for safety reasons             No information available.
Special hazards arising from the substance or mixture Flammable. Containers may explode when heated. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back.
Hazardous Combustion Products Carbon monoxide (CO), Carbon dioxide (CO2).
Advice for firefighters As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full

Personal precautions, protective equipment and emergency procedures Use personal protective equipment. Keep people away from and upwind of spill/leak. Evacuate personnel to safe areas. Ensure adequate ventilation. Remove all sources of ignition. Take precautionary measures against static discharges.
Environmental precautions Should not be released into the environment. See Section 12 for additional ecological information.
Methods and materials for
containment and cleaning up
Soak up with inert absorbent material. Keep in suitable, closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment.
Reference to other sections Refer to protective measures listed in Sections 8 and 13

Precautions for safe handling Use only under a chemical fume hood. Wear personal protective equipment. Do not get in eyes, on skin, or on clothing. Do not ingest. Do not breathe vapors or spray mist. If peroxide formation is suspected, do not open or move container. Keep away from open flames, hot surfaces and sources of ignition. Use only non-sparking tools. To avoid ignition of vapors by static electricity discharge, all metal parts of the equipment must be grounded. Take precautionary measures against static discharges.   
Hygiene Measures Handle in accordance with good industrial hygiene and safety practice.   
Conditions for safe storage, including any incompatibilities Keep containers tightly closed in a dry, cool and well-ventilated place. Containers should be dated when opened and tested periodically for the presence of peroxides. Should crystals form in a peroxidizable liquid, peroxidation may have occurred and the product should be considered extremely dangerous. In this instance, the container should only be opened remotely by professionals. Keep away from heat and sources of ignition.   
Specific end use(s) Use in laboratories  
Exposure limits List source(s)  
Biological limit values This product, as supplied, does not contain any hazardous materials with biological limits established by the region specific regulatory bodies.  
Monitoring methods BS EN 14042:2003 Title Identifier: Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents. MDHS70 General methods for sampling airborne gases and vapours MDHS 88 Volatile organic compounds in air. Laboratory method using diffusive samplers, solvent desorption and gas
chromatography MDHS 96 Volatile organic compounds in air - Laboratory method using pumped solid sorbent tubes, solvent desorption and gas chromatography
 
Predicted No Effect Concentration
(PNEC)
Fresh water 6.4 mg/l
Fresh water sediment 25.7 mg/kg
Marine water 0.64 mg/L
Marine water sediment 2.57 mg/kg
Water Intermittent 40 mg/L
Microorganisms in sewage treatment 20 mg/L
Soil (Agriculture) 1.39 mg/kg
 
Engineering Measures Use only under a chemical fume hood. Ensure that eyewash stations and safety showers are close to the workstation location. Use explosion-proof electrical/ventilating/lighting/equipment. Ensure adequate ventilation, especially in confined areas. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source  
Personal protective equipment Eye Protection Safety glasses with side-shields (European standard - EN 166) Hand Protection Protective gloves  
Skin and body protection Long sleeved clothing Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.  
Respiratory Protection When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly.  
Small scale/Laboratory use Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure
imits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Valve filtering: EN405; or; Half mask: EN140; plus filter, EN
141
When RPE is used a face piece Fit Test should be conducted
 
Environmental exposure controls No information available. 

                                       

            Gloves                       Suit                          

  

Appearance Colorless
Physical State Liquid
Odour Petroleum distillates
Odor Threshold No Data Available
pH No Data Available
Melting Point/Range 69 °C / -92.2 °F
Softening Point No Data Available
Boiling Point/Range 84 - 86 °C / 183.2 186.8 °F @ 760 mmHg
Flash Point -6 °C / 21.2 °F Method No Information Available
Flammability (solid, gas) Not applicable Liquid
Upper explosion limit 10.4 vol%
Lower explosion limit 1.6 vol%
Vapor Density 3.1 (Air = 1.0) (Air = 1.0)
Vapor pressure 64 hPa @ 20 °C
Specific Gravity / Density 0.867
Bulk Density Not applicable Liquid
Water solubility Miscible
Solubility in other solvents No information available
Partition coefficient: octanol log Pow
Autoignition temperature 200 200 - °C / 392 - °F
Ethylene glycol dimethyl ether 0.21
Decomposition Temperature No data available
Viscosity  1.1 mPa.s at 20 °C
Explosive Properties No data available Vapors may form explosive mixtures with air
Oxidizing Properties No information available
Other information Molecular Formula C4 H10 O2
Molecular Weight 90.12
Recativity                                             None known, based on information available
Stability Stable under normal conditions.
Possibility of hazardous reactions Hazardous Polymerization Hazardous polymerization does not occur.
Hazardous Reactions None under normal processing.
Conditions to avoid Incompatible products. Excess heat. Keep away from open flames, hot surfaces and sources of ignition.
Incompatible materials Strong oxidizing agents.
Hazardous decomposition products Carbon monoxide (CO). Carbon dioxide (CO2).
Acute Toxicity Oral Based on available data, the classification criteria are not met
Dermal Based on available data, the classification criteria are not met
Inhalation Category 4
Skin corrosion/irritation Category 2
Serious eye damage/irritation Based on available data, the classification criteria are not met
Respiratory or skin sensitization Respiratory Based on available data, the classification criteria are not met
Skin Based on available data, the classification criteria are not met
Inhalation Inhalation of vapours leads to irritation of respiratory tract and mucous membranes, headache, nausea, dizziness, vomiting. Sensitisation possible through inhalation
Germ cell mutagenicity Based on available data, the classification criteria are not met
Carcinogenicity Based on available data, the classification criteria are not met
The table below indicates whether each agency has listed any ingredient as a carcinogen
Reproductive toxicity Category 1B
Reproductive Effects May impair fertility. Developmental Effects May cause harm to the unborn child.
STOT-single exposure Based on available data, the classification criteria are not met Target Organs None known.
STOT-repeated exposure Based on available data, the classification criteria are not met Target Organs None known.
Aspiration Hazard Based on available data, the classification criteria are not met Other Adverse Effects.
Other Adverse Effects The toxicological properties have not been fully investigated.
Symptoms / effects,both acute and delayed Inhalation of high vapor concentrations may cause symptoms like headache, dizziness,
tiredness, nausea and vomiting.


Environmental Effects Do not empty into drains
Persistence and degradability Persistence Not readily biodegradable Persistence is unlikely, based on information available.
Bioaccumulative potential Bioaccumulation is unlikely
Mobility in soil                 The product contains volatile organic compounds (VOC) which will evaporate easily from all
surfaces Will likely be mobile in the environment due to its volatility. Disperses rapidly in air
Results of PBT and vPvB Assessment Substance is not considered persistent, bioaccumulative and toxic (PBT) / very persistent and very bioaccumulative (vPvB).
Other adverse effects Endocrine Disruptor Information This product does not contain any known or suspected endocrine disruptors Persistent Organic Pollutant This product does not contain any known or suspected substance Ozone Depletion Potential This product does not contain any known or suspected substance

 

Waste from Residues / Unused
Products
Waste is classified as hazardous. Dispose of in accordance with the European Directives
on waste and hazardous waste. Dispose of in accordance with local regulations.
Contaminated Packaging Dispose of this container to hazardous or special waste collection point. Empty containers retain product residue, (liquid and/or vapor), and can be dangerous. Keep product and empty container away from heat and sources of ignition.
European Waste Catalogue (EWC) According to the European Waste Catalogue, Waste Codes are not product specific, but application specific.
Other Information Waste codes should be assigned by the user based on the application for which the product was used. Do not dispose of waste into sewer. Can be incinerated, when in compliance

 Land transport (DOT) / ADR/ ADNR / IATA / 

UN        Number                                          UN2252
Proper shipping name 1,2-DIMETHOXYETHANE
Class 3
Packing Group II

Request the signed SDS as PDF

Availability

1,2-DIMETHOXYETHANE manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of 1,2-DIMETHOXYETHANE at a competitive price from us. We have ready stock of 1,2-DIMETHOXYETHANE in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.