RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,061 products across 71 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Lab Chemical

Aluminum Chlorid 0.1 M

Lab Reagent
Part number
RXSOL-60-6274-100
Category
Lab Chemical
Brand
RXSOL
Aluminum Chlorid 0.1 M

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name RXSOL-60-6274-100
Product Type Aluminum Chlorid 0.1 M

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA 

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
SARA 313 Component  CAS Number Percent Comp. Dimension
 
Exposure
 Limits
 

Aluminum Chloride Hexahydrate

 CAS# 7784-13-6 2 - 3% W/V ACGIH TWA 2 mg (Al)/mƒ
Water, Deionized ASTM Type II CAS# 7732- 18-5  97-98% V/V None
 Established  

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.

Emergency Overview: May Cause eye and skin burns. May cause severe respiratory tract
irritation with possible burns. May cause severe digestive tract irritation with possible burns. Water-Reactive.

Inhalation: Mists are Irritants to Respiratory Tract.

Ingestion: Swallowing may Cause Burns of the Mouth, Throat and Stomach.

Skin: Can be Corrosive to Skin. May Cause Irritation.

Eye Contact: May Cause Irritation to Eyes, and with Greater Exposure, Severe Burns with
Possibly Blindness Resulting. Sodium Azide: Causes Irritation, Redness, Pain, and Blurred Vision.

Chronic Exposure: Persons with Pre-Existing Skin Disorders may be Susceptible to these
Solutions.

Aggravated by Exposure: Chronic Respiratory Disease, Pre-Existing Eye Problems and Skin Disease.

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.

 

SKIN:

Remove contaminated clothing. Wash exposed area with soap and
water. if irritation persists, seek medical attention.

  EYES: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally.
Seek Medical Aid.
  INHALATION: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen
  INGESTION  Give several glasses of milk or water. Vomiting may occur

Fire Extinguisher Type:

Any means suitable for extinguishing
surrounding fire

Fire / Explosion Hazards:  None Known.
Fire Fighting Procedure: Wear self-contained breathing apparatus and protective
clothing to prevent contact with skin and clothing.

Dispose of in a manner consistent with federal, state and local regulations.Ventilate area of Leak or Spill. Keep Unnecessary and Unprotected People away from the area of Spill. Wear Appropriate Personal Protective Equipment as Specified in Section 8. Contain and Recover Liquid when Possible. Use Non-Sparking Tools and Equipment. Collect Liquid in an Appropriate Container or Absorb with an Inert Material (e.g., Vermiculite, Dry Sand, Earth). Do Not Use Combustible Materials, such as Saw Dust. Do Not Flush to Sewer! US Regulations (CERCLA) Require Reporting Spills and Releases to Soil, Water and Air in Excess of Reportable Quantities.

Store in a cool, dry, well-ventilated place away from incompatible materials. Wash thoroughly after handling.

Respiratory Protection

None required

Ventilation  Local 
OTHER Mechanical

Protective Gloves

Gloves to prevent skin exposure as rubber or vinyl

EYE PROTECTION Splash Goggles
Other Protective Equipment Use safe laboratory handling
procedures.
BOILING POINT ~100° C (212° F)
VAPOR PRESSURE   Information not available
MELTING POINT ~0° C (32° F)
VAPOR DENSITY   Information not available
EVAPORATION RATE  Information not available
Appearance /Odors Clear,colorless, available
Flash Point Information not available
Specific Gravity Information not available
Percent Volatile by >97
Evaporation Standard  

Auto Ignition Temp

Information not available

Lower Flamm. Limit in Air

Information not available

Upper Flamm. Limit in Air Information not available
Solubility in Water Soluble

STABILITY

Stable

CONDITIONS TO AVOID

Heat

MATERIALS TO AVOID

information not available

HAZARDOUS DECOMPOSITION PRODUCTS

HCl fumes

HAZARDOUS POLYMERIZATION

Will Not Occur
Conditions to Avoid  None known

 Carcinogenic References: IARC Category - None, NTP Carcinogen - Known: No

Environmental Fate: No Information Found.

Environmental Toxicity: No Information Found.

Waste must be disposed of in accordance with federal, state and local environmental control regulations.

DOT Classification: Not Regulated

DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations. 

CAS# 7784-13-6 is not listed on the TSCA inventory. It is for research and development use only. 

Conditions aggravated/Target organs: Persons with preexistion skin, eye, or respiratory disorders are more susceptible. Acute: May cause irritation and pain to skin, eyes, lungs, and gastro- intestinal tract. Nausea, coughing. Chronic: Dermatitis.

                                                              Flammability

Health                                                                                                      Reactivity

                                                                                   

Revisions

NFPA
   0
 8/2/2010  0.1  updated msds to 16 section from 10 section msds. STN
 

The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.


 

Request the signed SDS as PDF

Availability

Aluminum Chlorid 0.1 M manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Aluminum Chlorid 0.1 M at a competitive price from us. We have ready stock of Aluminum Chlorid 0.1 M in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches