Ammonium Thiocyanate AR
- Part number
- RXSOL-60-6132-500
- Category
- Lab Chemical
- Brand
- RXSOL
Overview
Ammonium Thiocyanate Analytical reagent grade supplier in India and Middle East.
Technical specifications
| Assay | Min.98% |
| Heavy metals (as Pb) | Max. 5ppm |
| Insolubility in water | Max. 50 ppm |
| Cl (Chloride) | Max. 50 ppm |
| So4 (Sulphate) | Max. 100 ppm |
| Fe (Iron) | Max. 1 ppm |
| pH (200c; 5%) | 4.2 to 5.8 |
| Ignition residue (So4) | Max. 0.025% |
| Substances reducing iodine | Max. 0.4% |
| S (Sulphide) | Max. 10 ppm |
| Cu (Copper) | Max. 4 ppm |
| Pb (Lead) | Max.4 ppm |
Applications
Ammonium thiocyanate is used in chemical analysis, in photography, as a fertilizer, and for many other uses.
#AMMONIUMthiocynate_QATAR
Dosage and directions
Other valuable Product:
Silver nitrate (Analytical reagent grade) – 100gm – CAS no – 7761-88-8
Ammonium iron (III)sulfate dodecahydrate (for analysis) – 200 gm
Nitric Acid (2 lit)
Sulphuric Acid (Con H2SO4) – 1 lit.
Hydrochloric Acid ( Con HCL) – 1 lit.
Characteristics and notes
Ammonium thiocyanate is a colorless crystalline solid. It is soluble in water.
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | Ammonium Thiocyanate |
| Part Number | RXSOL-60-6132-500 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Sikka, Dahej, Hazira, JNPT, Goa, Mangalore, Cochin, Tuticorin, Chennai, Kakinada, Vizag, Paradip, Kolkata, UAE, muscat
| Phone | +91 22 27815540 / 41 / 42 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com | |
| Website | www.rxmarine.com |
| Product Name | CAS-No. | Classification | Concentration |
| Ammonium thiocyanate | 1762-95-4 | Acute Tox. 4; Aquatic Chronic | <= 100 % |
| Classification according to Regulation (EC) No 1272/2008 |
Acute toxicity, Inhalation (Category 4), H332 Acute toxicity, Dermal (Category 4), H312 Acute toxicity, Oral (Category 4), H302 Chronic aquatic toxicity (Category 3), H412 For the full text of the H-Statements mentioned in this Section, see Section 16. |
| Hazard statement(s) |
H302 + H312 + H332Harmful if swallowed, in contact with skin or if inhaled H412Harmful to aquatic life with long lasting effects. |
| Precautionary statement(s) |
P273 Avoid release to the environment. P280 Wear protective gloves/ protective clothing. |
| Supplemental Hazard information (EU) | EUH032 Contact with acids liberates very toxic gas. |
| Other hazards | None |
| General advice | Consult a physician. Show this safety data sheet to the doctor in attendance. |
| Inhaled | If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician. |
| Skin contact | Wash off with soap and plenty of water. Consult a physician. |
| Eye contact | Flush eyes with water as a precaution. |
| Swallowed | Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician. |
| Most important symptoms and effects, both acute and delayed | The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11 |
| Indication of any immediate medical attention and special treatment needed | No Data Available |
| Extinguishing media | Suitable extinguishing media Dry powder |
| Special hazards arising from the substance or mixture | Carbon oxides, nitrogen oxides (NOx), Sulphur oxides. |
| Advice for firefighters | Wear self contained breathing apparatus for fire fighting if necessary. |
| Further information | No Data Available |
| Personal precautions, protective equipment and emergency procedures | Wear respiratory protection. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Avoid breathing dust. For personal protection see section 8. |
| Environmental precautions | Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. |
|
Methods and materials for containment and cleaning up |
Pick up and arrange disposal without creating dust. Sweep up and shovel. Do not flush with water. Keep in suitable, closed containers for disposal. |
| Reference to other sections | For disposal see section 13. |
| Precautions for safe handling | Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2. | |
| Conditions for safe storage, including any incompatibilities |
Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Never allow product to get in contact with water during storage. Do not store near acids. |
|
| Specific end use(s) | A part from the uses mentioned in section 1.2 no other specific uses are stipulated. |
| Appropriate engineering controls | Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday. | |
| Personal protective equipment |
Eye/face protection Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). |
|
| Skin protection | Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. | |
| Body Protection | Complete suit protecting against chemicals, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. | |
| Respiratory protection | Where risk assessment shows air-purifying respirators are appropriate use a full-face particle respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU). | |
| Control of environmental exposure | Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. |
Gloves Suit
| Appearance | Solid |
| Odour | Odourless |
| Odor Threshold | No Data Available |
| pH | 4,0 - 5,5 at 76,1 g/l at 25 °C |
| Melting Point/Range | 152 - 154 °C Point |
| Initial boiling point and boiling range | No Data Available |
| Flash point | Not Applicable |
| Evapouration rate | No Data Available |
| Flammability (solid, gas) | No Data Available |
|
Upper/lower flammability or explosive limits |
No Data Available |
| Vapour pressure | 0,000114 hPa at 20 °C |
| Vapour density | No data available |
| Relative density | 1,300 g/cm3 |
| Water solubility | ca.76,1 g/l at 20 °C |
| Partition coefficient | n- log Pow: -2,287 - The preceding data, or interpretation of data, was octanol/water determined using Quantitative Structure Activity Relationship (QSAR) modeling. |
| Auto-ignition | No Data Available |
| Decomposition | No Data Available |
| Viscosity | No Data Available |
| Explosive properties | No Data Available |
| Oxidizing properties | No Data Available |
| Other safety information | No Data Available |
| Recativity | No Data Available |
| Stability | Stable under recommended storage conditions. |
| Possibility of hazardous reactions | No Data Available |
| Incompatible materials | Strong oxidizing agents, Strong acids, Forms shock-sensitive mixtures with certain other materials., Lead nitrate |
| Condition to Avoid | Avoid moisture. Exposure to air may affect product quality. |
| Hazardous decomposition products | In the event of fire: see section 5. |
| Acute toxicity | LD50 Oral - rat - 750 mg/kg |
| Skin corrosion/irritation | No Data Available |
| Serious eye damage/eye irritation | No Data Available |
| Respiratory or skin sensitisation | No Data Available |
| Germ cell mutagenicity | No Data Available |
| Carcinogenicity IARC | No component of this product present at levels g |
Availability
Ammonium Thiocyanate supplier in Mumbai, Kandla Gandhidham Gujrat Surat, Visakhapatnam, Kolkata, Chennai, Fujairah, Dubai, Sharjah, Ajman, Abudhabi, Muscat - Oman, Nairobi Kenya