Overview
Brine Corrosion Inhibitor RXSOL is a Fatty amine derivative with biocide and oxygen scavenger borate-organic corrosion inhibitor especially designed for use in chloride brine closed re-circulating cooling systems. Brine Corrosion Inhibitor RXSOL provides effective corrosion protection for steel and most other metals in both low and high temperature systems and is formulated to perform without additional supplements. It can be used in chromate containing systems without causing precipitation.
Technical specifications
Physical Properties
| - Odour | Odourless |
|---|---|
| - Appearance | colourless to yellow, miscible with water |
| - pH 11,5 | 14 |
- Boiling point 100 °C at 760 mm /Hg
| - Density 1,155 | 1,190 g/cm3 at 20 deg C |
|---|
Applications
Corrosion Inhibitor chloride brine closed re-circulating cooling systems.
Dosage and directions
The recommended dosage for Brine Corrosion Inhibitor RX is 17.5 litres per tonne of brine in the system. Brine Corrosion Inhibitor Rx may be added directly to the system either neat or in a water dilution. Dilutions should be made with evaporated water. If a chemical dosing pump is used then pump and lines should be mild steel, stainless steel, Teflon, polyethylene, PVC, polypropylene or rubber.
Conversion from chromate Brine corrosion inhibitor RX is compatible with chromate. Systems with chromate need not be flushed before adding the product. Let chromate deplete naturally and maintain boron level at a minimum of 70ppm. Brine Corrosion Inhibitor Rx should be fed slowly. Start feeding 5 to 10% of the total dosage at a time and watch for foaming. Gradually increase the feed rate. Brine Corrosion Inhibitor Rx does not induce foaming at normal dose rates, but if it is fed too much too soon, foaming may occur. Feed lines and pumps should be mild steel, stainless steel, Teflon, polyethylene, PVC polypropylene or rubber.
Testing and Control Control Brine Corrosion Inhibitor RXSOL as Boron at 70 - 100 ppm Note: Because the specific gravity of the brine varies with concentration, the resulting level of boron should be calculated.
Characteristics and notes
Features
- Formulated for brine cooling systems
- Liquid - easy to handle.
- Multi metal corrosion protection.
Benefits
- Can be used to replace chromate technology
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | : BRINE CORROSION INHIBITOR |
| Part Number | : RXSOL-81-4049-210 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Mumbai , Chennai, Vizag, Kolkata, Fujairah UAE, Muscat, Nairobi and CANADA
| Phone | +91 22 2087 1200 - 1400 |
| Fax | +91 22 2761 2100 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com | |
| Website | www.rxmarine.com |
| Name of Substance | Cas Number | EINECS No | Wt.% | Symbol |
| Sodium Borate Anhydrous | 1330-43-4 | 215-540-4 | 5 -10% | Xi |
| Sodium Hydroxide | 310-73-2 | 215-185-5 | 1- 2% | C |
| Proprietory Blend of Inhibitor | --- | --- | 21-30% |
| Signal Word | Warning |
| Hazard Statements |
H315 Causes skin irritation. |
| Precautionary statements - prevention |
P101 If medical advice is needed, have product container or label at hand. P102 Keep out of reach of children. P103 Read carefully and follow all instructions. P201 Obtain special instructions before use. P280 Wear protective gloves, protective clothing, eye protection and face protection. P264 Wash all exposed external body areas thoroughly after handling. |
| Precautionary statements - response |
P308+P313 IF exposed or concerned: Get medical advice/ attention. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337+P313 If eye irritation persists: Get medical advice/attention. P302+P352 IF ON SKIN: Wash with plenty of water. P332+P313 If skin irritation occurs: Get medical advice/attention. P362+P364 Take off contaminated clothing and wash it before reuse. |
| Eye Contact | Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention immediately. |
| Skin Contact | Wash off immediately with plenty of water for at least 15 minutes. Use a mild soap if available. Wash clothing before reuse. Thoroughly clean shoes before reuse. Get medical attention immediately. |
| Inhalation: | If inhaled, If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician. |
| Ingestion: | If swallowed, do not induce vomiting. Allow victim to rinse his mouth and then to drink 2-4 cupfuls of water. Never give anything by mouth to an unconscious person. Call a physician. |
| Notes to Physicians | Treat symptomatically. |
| Flammability | Non Flammable |
| Suitable extinguishing media | Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. |
| Protective Equipment | Use personal protective equipment. |
| Advice for firefighters | Wear self-contained breathing apparatus. Wear full protective equipment. |
| Specific extinguishing methods | Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations. In the event of fire and/or explosion do not breathe fumes. |
| Personal precautions, protective equipment and emergency procedures |
Ensure adequate ventilation. Keep people away from and upwind of spill/leak. Avoid inhalation, ingestion and contact with skin and eyes. Wear suitable personal protective equipment.Respiratory protective equipment. |
| Enviromental Precaution | Do not allow contact with soil, surface or ground water.If the products get into drains, inform the relevant authorities immediately. |
|
Methods and materials for containment and cleaning up |
Stop leak if safe to do so. Contain spillage, and then collect with noncombustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13). Flush away traces with water. For large spills, dike spilled material or otherwise contain material to ensure runoff does not reach a waterway. |
| Advice on safe handling | Do not ingest. Do not get in eyes, on skin, or on clothing. Do not breathe dust/ fume/ gas/ mist/ vapors/ spray. Use only with adequate ventilation. Wash hands thoroughly after handling. |
| Storage | Do not store near acids. Keep out of reach of children. Store in suitable labeled containers. Storage temperature : 10 °C to 50 °C |
| Advice on general occupational hygiene | Wash hands after use. Do not to eat, drink and smoke in work areas. Remove contaminated clothing and protective equipment before entering eating areas. |
| Engineering Control | Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. Well-designed engineering controls can be highly effective in protecting workers and will typically be independent of worker interactions to provide this high level of protection. The basic types of engineering controls are: Process controls which involve changing the way a job activity or process is done to reduce the risk. Enclosure and/or isolation of emission source which keeps a selected hazard "physically" away from the worker and ventilation that strategically "adds" and "removes" air in the work environment. Ventilation can remove or dilute an air contaminant if designed properly. The design of a ventilation system must match the particular process and chemical or contaminant in use. Employers may need to use multiple types of controls to prevent employee overexposure. | |||||||||||||||||||||||||
| Personal Protection |
Eye & face protection : Safety glasses with unperforated side shields may be used where continuous eye protection is desirable, as in laboratories; spectacles are not sufficient where complete eye protection is needed such as when handling bulk-quantities, where there is a danger of splashing, or if the material may be under pressure. Chemical goggles.whenever there is a danger of the material coming in contact with the eyes; goggles must be properly fitted. Full face shield (20 cm, 8 in minimum) may be required for supplementary but never for primary protection of eyes; these afford face protection. Alternatively a gas mask may replace splash goggles and face shields. Contact lenses may pose a special hazard; soft contact lenses may absorb and concentrate irritants. A written policy document, describing the wearing of lenses or restrictions on use, should be created for each workplace or task. This should include a review of lens absorption and adsorption for the class of chemicals in use and an account of injury experience. |
|||||||||||||||||||||||||
| Occupational Exposure Limits (OEL) |
|
|||||||||||||||||||||||||
|
Emergency Limits Ingredient |
|
|||||||||||||||||||||||||
| Hygiene measures | Handle in accordance with good industrial hygiene and safety practice. Remove and wash contaminated clothing before re-use. Wash face, hands and any exposed skin thoroughly after handling. Provide suitable facilities for quick drenching or flushing of the eyes and body in case of contact or splash hazard. |
Gloves Suit
| Form | Liquid |
| Colour | Yellow |
| Odour | Not Available |
| Odour threshold | Not Available |
| Boiling point and boiling range | 100°C |
| Flash Point | Non FlammableNo |
| Freezing Point | Not Available |
| pH | 11.5 -14 |
| Evaporation rate | Not available |
| Flammability (solid, gas) | Not Available |
| Upper explosion limit | Not Available |
| Lower explosion limit | Not Available |
| Explosive properties | Not Available |
| Vapor pressure | Not Available |
| Relative vapor density | Not Available |
| Relative density | 1.155 - 1.190 (25C) |
| Water solubility | Miscible |
| Solubility in other solvents | Not Available |
| Partition coefficient: octanol | Not Available |
| Autoignition temperature | Not Available |
| Thermal decomposition | Not Available |
| Viscosity, kinematic | Not Available |
| Explosive properties | Not Available |
| Oxidizing properties | Not Available |
| Molecular weight | Not Available |
| VOC | Not Available |
| Recativity | None |
| Stability | Stable under normal conditions. |
| Possibility of hazardous reactions | No dangerous reaction known under conditions of normal use. |
| Incompatible materials |
Avoid to contact with strong acids Avoid to contact with oxidizing agents. Store away from aldehydes. |
| Hazardous Decomposition |
Decomposition products may include the following materials: |
| Condition to Avoid | None Known |
| Polymerization | Will not occur. |
| Route of Exposure | Inhalation, Eye contact, Skin contact |
| Eyes |
Causes serious eye damage. |
| Skin | Causes severe skin burns. |
| Ingestion | Causes digestive tract burns |
| Inhalation | Inhalation of vapours leads to irritation of respiratory tract and mucous membranes, headache, nausea, dizziness, vomiting. Sensitisation possible through inhalation |
| Chronic Exposure | Health injuries are not known or expected under normal use. |
| Acute oral toxicity | Oral (man) LDLo: 709 mg/kg[2] |
| Acute inhalation toxicity | No data available |
| Acute dermal toxicity | No data available |
| Classification | The classification was made by the conventional (calculation) method of Dangerous Preparations Directive(1999/45/EC) |
| Environmental Effects | No data available |
| Toxicity to fish |
Endpoint Test Duration (hr) Species Value Source EC50 96h Algae or other aquatic plants 2.6-21.8mg/l 4 |
| Toxicity to daphnia and others |
Endpoint Test Duration (hr) Species Value Source EC50 48h Crustacea 34.59-47.13mg/l 4 EC50(ECx) 48h Crustacea 34.59-47.13mg/l 4 LC50 96h Fish 144-267mg/l 4 |
| Toxicity to algae | No data available |
| Biodegradability | Low (28 d) |
| Persistence and degradability | No data available |
| Bioaccumulative potential | No data available |
| Mobility in soil | No data available |
| Remarks | Please consider the relevant national or regional provisions. Waste shall be separated into the categories that can be handled separately by the local or national waste management facilities. |
| Waste Disposal | The product should not be allowed to enter drains, water courses or the soil. Where possible recycling is preferred to disposal or incineration. If recycling is not practicable, dispose of in compliance with local regulations. Dispose of wastes in an approved waste disposal facility |
Not classified as hazardous forany mode of Transport
| DOT | TDG Classification | IMDG | IATA | |
| UN Number | Not Regulated For transort | Not Regulated For transort | Not Regulated For transort | Not Regulated For transort |
| Proper shipping name | Not Regulated For transort | Not Regulated For transort | Not Regulated For transort | Not Regulated For transort |
|
Transport hazard class(es) |
Not Applicable | Not Applicable | Not Applicable | Not Applicable |
| Packing Group | Not Applicable | Not Applicable | Not Applicable | Not Applicable |
|
Environmental hazards |
NO | NO | NO | NO |
| US Federal Regulations | All components of this product are listed, or excluded from listing, on the United States Environmental Protection Agency Toxic Substances Control Act (TSCA) inventory. This product or mixture does not contain a toxic chemical or chemicals in excess of the applicable de minimis concentration as specified in 40 CFR §372.38(a) subject to the reporting requirements of section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 and 40 CFR Part 372. |
| WHMIS Classification | Class D Division 2 Subdivision A - Very toxic material causing other toxic effects |
| Further information |
FOR INDUSTRIAL USE. Water Hazard Class:. WGK 1. |
| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if RX Marine International has been advised of the possibility of such damages. DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable. |
Availability