RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,061 products across 71 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Lab Chemical

Buffer Solution pH 4

We also have ready stock of Colour code pH Buffers 1.68, 4.01, 7.00, 6.86, 9.18, 10.01, 12.45
Part number
RXSOL-60-6206-030
Category
Lab Chemical
Brand
RXSOL
Buffer Solution pH 4

Overview

Buffer mixture can be made from a mixture of an acid and its conjugate base.  We also have ready stock of Colour code pH Buffers  1.68, 4.01, 7.00, 6.86, 9.18, 10.01, 12.45
Available with ready stock for accurate calibration with traceability certificate.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name RXSOL-60-6206-030
Product Type Buffer Solution, pH 4

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com

  

SARA 313 Component  CAS Number Percent Comp. Dimension
 
Exposure
 Limits
 
Methyl Red Sodium Salt   845-10-3  < W/V  None
Established
 
Potassium Hydrogen Phthalate 877-24-7  1.02% W/V TXDS: orl-rat
LD•: 3200
mg/Kg
 
Thymol Crystal 89-83-8 0.01% W/V TXDS: orl-rat
LD•: 640
mg/Kg
 
Water, Deionized ASTM Type II 7732-18-5  Balance V/V None
Established

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling. Keep

Emergency Overview:Caution! May Cause Irritation to Skin and Eyes.

Inhalation:No Adverse Health Effects Expected from Inhalation.

Ingestion:Large Doses may Cause Stomach Upset.

Skin:Not Expected to be a Health Hazard from Skin Exposure. May Cause Mild Irritation and Redness.

Eye Contact:Not Expected to be a Health Hazard. May Cause Mild Irritation, Possible Reddening.

Chronic Exposure:No Information Found.

Aggravated by Exposure:No Information Found.

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling. Keep container closed.

SKIN:

Wash exposed area with soap and water. If irritation persists, seek medical attention.

EYES: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally. Seek Medical Aid. INHALATION: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen
INGESTION:  If swallowed, induce vomiting immediately after giving two glasses of water. Never give anything by mouth to an unconscious person

Fire Extinguisher Type:

Any means suitable for extinguishing surrounding fire

Fire / Explosion Hazards:  None
Fire Fighting Procedure: Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and clothing.

Absorb spill with inert material. Flush excess down drain. Ventilate area of Leak or Spill. Keep Unnecessary and Unprotected People away from the area of Spill. Wear Appropriate Personal Protective Equipment as Specified in Section 8. Contain and Recover Liquid when Possible. Collect Liquid in an Appropriate Container or Absorb with an Inert Material (e.g., Vermiculite, Dry Sand, Earth). Do Not use Combustible Materials, such as Saw Dust. US Regulations (CERCLA) Require Reporting Spills and Releases to Soil, Water and Air in Excess of Reportable Quantities.

Store in a cool dry place. This Material is not considered hazardous. Handle using safe laboratory practices.

Respiratory Protection

None required

Ventilation Local
OTHER Mechanical
Protective Gloves Gloves to prevent skin exposure as rubber or vinyl
EYE PROTECTION Safety Glasses w/Side Shields
Other Protective Equipment  Use safe laboratory handling procedures.

         

BOILING POINT   ~100° C
VAPOR PRESSURE     Information not available
MELTING POINT  ~0° C
VAPOR DENSITY    Information not available
EVAPORATION RATE  Information not available
Appearance /Odors Clear red  solution/Slight benzoic acid odor
Flash Point  not flammable
Specific Gravity ~ 1
Percent Volatile by  >99%
 
Evaporation Standard  
Auto Ignition Temp

Not applicable

Lower Flamm. Limit in Air Not applicable
Upper Flamm. Limit in Air  Not applicable
 
Solubility in Water Soluble

STABILITY

Stable

CONDITIONS TO AVOID

  High temperature, air

MATERIALS TO AVOID

 Strong acids and bases

HAZARDOUS DECOMPOSITION PRODUCTS

Not known to occur

HAZARDOUS POLYMERIZATION

 Will Not Occur
Conditions to Avoid  None known

Carcinogenic References: NTP Carcinogen - Known: No, IARC Category- None

No Information Found.

Whatever cannot be saved for recovery or recycling should be managed in an appropriate and
approved waste disposal facility. Processing, use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements.

DOT Classification: Not Regulated

DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations.

Chemical Inventory Status –
Part 1:Ingrdient
Potassium Acid Phthalate (877-24-7)
TSCA               Yes
EC                    Yes
Japan              No
Australia          Yes

Chemical Inventory Status –
Part 2:Ingredient
Potassium Acid Phthalate (877-24-7)
Korea               Yes
DSL                  Yes
NDSL               NO
Phil.                 Yes

Federal, State & International Regulations –
Part 1: Ingredient.
Potassium Acid Phthalate (877-24-7)
RQ                             NO
TPQ                           NO
List                             NO
Chemical Catg        No

Federal, State & International Regulations –
Part 2:Ingredient
Potassium Acid Phthalate (877-24-7)
CERCLA                 NO
261.33                     No
8(d)                           No

Chemical Weapons Convention:No
TSCA 12 (b):No
CDTA:NO             Mixture/Liquid)
SARA 311/312: Acute: Yes
Chronic:             NO
Fire:                    No
Pressure:          No
Reactivity:          No
Australian Hazchem Code: None
Poison Schedule: None allocated

Overexposure symptoms. Acute: Essentially non-hazardous. Possible irritation of eyes/stomach. Chronic: None known. Conditions aggravated/Target organs: none known.

                                                              Flammability


Health                                                                                                      Reactivity

                                                                                               

Revisions

  NFPA
  0
7/28/2010  0.1 updated msds to 16 section from 10 section msds. STN

The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Buffer pH 4 solution manufacturer and supplier in Mumbai, Kandla, Kolkata, Gandhidham, Sohar, Barka, Ajman, Abudhabi, Dubai, Fujairah, VISAKHAPATNAM, chennai, CANADA

Our stock points and branches