RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,116 products across 118 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Boiler Chemicals

CorroSOL 30 Polymer Caustic Scale Sludge Conditioner

Product to be used in situations where the boiler water is contaminated with oil. This high performance product is applicable to both medium and low-pressure steam boilers in order to prevent sludge deposits.
Part number
RXSOL-42-5010-050
Generic name
Sludge Conditioner
Active matter
63-72
Brand
RXSOL
RXSOL

Overview

Corrosol 30 Sludge Conditioner is a high-performance boiler treatment formulation designed for effective pH control, sludge conditioning, and scale prevention in steam boiler systems.

This advanced product utilizes a strong alkaline base to elevate feedwater alkalinity, neutralize acidic components, and maintain optimal pH levels within the boiler.

In addition to its pH control function, Corrosol 30 incorporates specialized high-temperature polymers that efficiently condition sludge and inhibit scale formation, ensuring enhanced system cleanliness and heat transfer performance under demanding operating conditions.

Very effective corrosion, scale and sludge conditioners and also effective neutralized organic acids, pH. This will affect clear transparent BOILER WATER effect. 
BOILER SLUDGE CONDITIONER DESCRIPTION BOILER SLUDGE CONDITIONER is a product to be used in situations where the boiler water is contaminated with oil. This high performance product is applicable to both medium and low-pressure steam boilers in order to prevent sludge deposits.

Technical specifications

Specifications of CorroSOL 30 Polymer Caustic Scale Sludge Conditioner
This is a white high molecular weight solution. It is hydrophilic and of low causticity.
Appearance / ColorWhite, viscous liquid
pH8
OdorOdorless

Applications

Application Area Purpose
Steam Boilers Maintains feedwater alkalinity, disperses sludge, and prevents scale formation.
High-Pressure Boilers Ensures high-temperature stability and effective sludge conditioning under demanding conditions.
Boiler Start-Up Treatment Used as an initial treatment to clean and condition internal surfaces during commissioning.
Food & Beverage Industry Safe for use in steam systems where indirect steam contacts food surfaces.
Refineries & Petrochemical Plants Protects boiler tubes and systems from corrosion and fouling due to contaminated feedwater.
Power Plants Enhances reliability and efficiency by keeping boiler internals clean.
Pharmaceutical Industry Assures consistent boiler operation in clean utility systems.
Textile & Paper Industry Prevents scale and sludge deposits that can affect heat exchanger performance.

Note that BOILER SLUDGE CONDITIONER can be applied as it is or dissolved with other boiler treatment products. 

SAFETY AND HANDLING HANDLING Handle with care. Store in a dry, cool and well ventilated environment.

Product Benefits of CorroSOL 30 Sludge Conditioner pH Booster

  • Effective pH Control: Neutralizes acidic feedwater and maintains proper alkalinity levels.
  • Prevents Scale Formation: Inhibits hardness salt deposition on heat exchange surfaces.
  • Sludge Conditioning: Disperses sludge particles for easier blowdown and cleaner boiler operation.
  • High-Temperature Stability: Performs reliably in demanding steam boiler environments.
  • Enhanced Efficiency: Promotes better heat transfer and reduces fuel consumption.
  • Corrosion Protection: Minimizes risk of corrosion caused by acidic conditions or deposits.
  • Compatible with Other Treatments: Can be used in conjunction with oxygen scavengers and phosphate treatments.

Dosage and directions

A. Dosing Procedure Regularly, a volume of 100 ml of the BOILER SLUDGE CONDITIONER should be applied for every ton of water capacity, where oil contamination exists. How ever, in systems where severe oil contamination exists, off-line cleaning is required before the product can be applied. There after, the application should be repeated daily, for a period of two weeks, until oil removal is complete.

B. Feeding Procedure Feed directly to the boiler by using a bypass pot feeder or a suitable chemical injection pump. For low-pressure boilers the solution may be applied to the hot well or the condensate return tank.

Characteristics and notes

Environmentally safe, non-toxic product

Highly specialized combined polymer technology

Organic corrosion control

Stops excessive caustic build-up

Avoid hardness scale and sludge deposits

Operates with low dissolved solid levels

Quick, simple and accurate testing 

Drives to the coagulation of the oil droplets and their removal by blow-down. May be combined with other boiler water treatment products. Efficiently prevents the deposition of sludge. Easy to apply and use. 

Our others valauable Products : 
BOILER TREAT ONE SHOT

Combined Boiler Water Conditioner

A one-product treatment for all auxiliary boilers including waste heat, and exhaust gas boilers. it prevents scale formation, inhibits corrosion and conditions sludge.

HARDNESS CONTROL
Boiler Water Conditioner

Added to the boiler water to maintain optimum phosphate level, which prevents calcium and magnesium hardness salts formation. The precipitate can be removed by blow-down.

ALKALINITY CONTROL
Boiler Water Conditioner 

Added to the boiler water to maintain optimum alkalinity level to prevent corrosion. Due to this, Ca and Mg hardness salts cannot form and the precipitate is removed by blow-down.

HYDRAZIDE
Oxygen Scavenger 
Used for rapid removal of oxygen in boiler feed water and condensate systems, which prevents corrosion. It is the alternative for hazardous and potentially carcinogenic products.

BOILER TREAT COMBI
Organic Boiler Water Treatment 
Special blended low molecular weight compounds that elevate boiler water pH to levels, which reduce corrosion. It also prevents under deposit corrosion caused by excess alkalinity.

LIQUID COAGULANT
Oil and Sludge Conditioner 

Used to prevent formation of adherent deposits and sticky sludge in boilers,which are then removed by normal blow-down. It can also be used in the event of an oil contamination.

CONDENSATE CONTROL
Steam and Condensate Conditioner 

Injected into the condensate pump to prevent corrosion in steam and condensate lines.It’s also used to protect idle boilers from corrosion. It neutralizes acidic conditions in condensate systems and volatilizes with steam.

COOL WATER TREAT NCLT
Corrosion and Scale Inhibitor 
Provides an effective anodic inhibitor treatment and protects ferrous and non-ferrous metals. It deposits a microscopic protective film on surfaces and has built-in pH buffering compounds. It controls formation of hard scale deposits.

EVEPORATOR TREAT
Prevention of scale in Evaporators
Used in both high and low pressure evaporators to prevent foaming, carry-over and scale formation. It’s safe to use where distillate is used for drinking purposes. It prevents scale formation and avoids the need for acid descaling.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name RXSOL-50-5010-050
Product Type CorroSOL 30 Polymer Caustic Scale Sludge Conditioner

 Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Mumbai, Kolkata, Chennai, Kandla, Visakhapatnam, Fujairah UAE, Muscat Oman, Kenya, Canada

Phone +91 22 27815541 / 42
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com

Proprietory blend of alkaline sludge conditioning products.

Poison! Danger! Corrosive. May Be Fatal If Swallowed. Harmful If Inhaled. Causes Burns To Any Area Of Contact . Reacts With Water, Acids And Other Materials.

Potential Health Effects:-

Inhalation

Severe irritant. Effects from inhalation of dust or mist vary from mild irritation to serious damage of the upper respiratory tract, depending on severity of exposure. Symptoms may include sneezing, sore throat or runny nose. Severe pneumonitis may occur.

Ingestion

Corrosive! Swallowing may cause severe burns of mouth, throat, and stomach .Severe scarring of tissue and death may result. Symptoms may include bleeding, vomiting diarrhea, fall in blood pressure. Damage may appears days after exposure.

Skin Contact

Corrosive! Contact with skin can cause irritation or severe burns and scarring with greater exposures.

Eye  Contact

Corrosive! Causes irritation of eyes, and with greater exposures it can cause burns that may result in permanent impairment of vision, even blindness.

Chronic Exposure

Prolonged contact with dilute solutions or dust has a destructive effect upon tissue. Aggravation of Pre-existing Conditions: Persons with pre-existing skin disorders or eye problems or impaired respiratory function may be more susceptible to the effects of the substance.

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician.

Ingestion

Do Not Induce Vomiting! Give large quantities of water or milk if available. Never give anything by mouth to an unconscious person. Get medical attention immediately.

Skin Contact

Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Call a physician, immediately. Wash clothing before reuse.

Eye Contact

Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Get medical attention immediately.

Fire

Not considered to be a fire hazard. Hot or molten material can react violently with water. Can react with certain metals, such as aluminum, to generate flammable hydrogen gas.

Explosion

Not considered to be an explosion hazard.

Fire Extinguishing Media

Use any means suitable for extinguishing surrounding fire. Adding water to caustic solution generates large amounts of heat.

Ventilate area of leak or spill. Keep unnecessary and unprotected people away from area of spill. Wear appropriate personal protective equipment as specified in Section 8. Spills: Pick up and place in a suitable container for reclamation or disposal, using a method that does not generate dust. Do not flush caustic residues to the sewer. Residues from spills can be diluted with water, neutralized with dilute acid such as acetic, hydrochloric or sulfuric. Absorb neutralized caustic residue on clay, vermiculite or other inert substance and package in a suitable container for disposal.

Keep in a tightly closed container. Protect from physical damage. Store in a cool, dry,ventilated area away from sources of heat, moisture and incompatibilities. Always add the caustic to water while stirring; never the reverse. Containers of this material may be hazardous when empty since they retain product residues (dust, solids); observe all warnings and precautions listed for the product. Do not store with aluminum or magnesium. Do not mix with acids or organic materials.

Airborne Exposure Limits

OSHA

OSHA Permissible Exposure Limit (PEL)

2 mg/m3 Ceiling – ACGIH

Threshold Limit Value (TLV)

2 mg/m3 Ceiling

Ventilation System

A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recomm-ended Practices, most recent edition, for details.

Personal Respirators

If the exposure limit is exceeded, a half-face dust/mist respirator may be worn for up to ten times the exposure limit or the maximum use concentration specified by the appropriate regulatory agency or respirator supplier, whichever is lowest. A full-face piece dust/mist respirator may be worn up to 50 times the exposure limit, or the maximum use concentration specified by the appropriate regulatory agency, or respirator supplier, whichever is lowest. For emergencies or instances where the exposure levels are not known, use a full-face piece positive-pressure, air-supplied respirator.

WARNING

Air-purifying respirators do not protect workers in oxygen-deficient atmospheres.

Skin Protection                     

Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.

Eye Protection

Use chemical safety goggles and/or a full face shield where splashing is possible. Maintain eye wash fountain and quick-drench facilities in work area.

Appearance

Clear to opeque

Odor

Odorless

Solubility

100%

pH

3 - 14 (0.5% soln.)

Specific Gravity

1.2 – 1.53

% Volatiles by volume @ 21C (70F)

0

Boiling Point

1390C(2534F)

Melting Point

318C(604 F)

Vapor Pressure (mm Hg)

Negligible

Evoporation Rate (BuAc = 1)

No information found

Stability

Stable under ordinary conditions of use and storage. Very hygroscopic. Can slowly pick up moisture from air and react with carbon dioxide from air to form sodium carbonate.

Hazardous Decomposition Products

Decomposition by reaction with certain metals releases flammable and explosive hydrogen gas.Hazardous

Hazardous  Polymerization

Will not occur.

Incompatibilities

Contact with water, acids, flammable liquids, and organic halogen compounds, especially trichloroethylene, may cause fire or explosion. Contact with nitromethane and other similar nitro compounds causes formation of shock-sensitive salts. Contact with metals such as aluminum, tin, and zinc causes formation of flammable hydrogen gas.

Conditions to Avoid

Moisture, dusting and incompatibles.

Skin Irritation 

Irritant wash with soap water

Eye Irritat 

Moderate irritant , flush with copious amounts of water

Sensitization

Not Sensitizing .

(All above information as per data available with us)

Comment

Not applicable

Ecotoxicity 

Not applicable , Readily biodegradable

Water hazard class 2 (self-assessment)

Hazardous for water.

Do not allow product to reach ground water, water bodies or sewage system. Danger to drinking water if even small quantities leak into soil.

This material must be disposed with local national regulations. Product Recommendation ( Recommended cleaning agent: water ) Can be burnt under adherence to the necessary technical regulations. Disposal must be made according to official regulations.Can be reused or recycled after cleaning .
 

  • Marine pollutant: No
  • Transport/Additional information

• Irritating to eyes and skin.
• Safety phrases
2 Keep out reach of children
If swallowed, seek medical attention immediately
22  Harmful if swallowed
26  In case of contact with eyes, rinse immediately with plenty of water and
seek medical attention.
23  Do not Breathe
27  After contact with skin, wash immediately with plenty of water and soap and rinse thoroughly.
41  Risk of serious damage to eyes
• National regulations
 

These data are based on our present knowledge. However, they shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship.Department issuing data specification sheet Environment protection department.Note : No Enviromental Problems Are Expected If The Product Is Handled Correctly.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Technical bulletin

Open technical bulletin

Corrosol 30 Sludge Conditioner is a high-performance boiler treatment formulation designed for effective pH control, sludge conditioning, and scale prevention in steam boiler systems.

This advanced product utilizes a strong alkaline base to elevate feedwater alkalinity, neutralize acidic components, and maintain optimal pH levels within the boiler. In addition to its pH control function, Corrosol 30 incorporates specialized high-temperature polymers that efficiently condition sludge and inhibit scale formation, ensuring enhanced system cleanliness and heat transfer performance under demanding operating conditions.

Advantages of CorroSOL 30


  • Effective pH Control: Neutralizes acidic feedwater and maintains proper alkalinity levels.
  • Prevents Scale Formation: Inhibits hardness salt deposition on heat exchange surfaces.
  • Sludge Conditioning: Disperses sludge particles for easier blowdown and cleaner boiler operation.
  • High-Temperature Stability: Performs reliably in demanding steam boiler environments.
  • Enhanced Efficiency: Promotes better heat transfer and reduces fuel consumption.
  • Corrosion Protection: Minimizes risk of corrosion caused by acidic conditions or deposits.
  • Compatible with Other Treatments: Can be used in conjunction with oxygen scavengers and phosphate treatments.

Properties


Parameter Result
Appearance Clear Liquid
pH Alkaline
Odour Characteristic

Applications


Application Area Purpose
Steam Boilers Maintains feedwater alkalinity, disperses sludge, and prevents scale formation.
High-Pressure Boilers Ensures high-temperature stability and effective sludge conditioning under demanding conditions.
Boiler Start-Up Treatment Used as an initial treatment to clean and condition internal surfaces during commissioning.
Food & Beverage Industry Safe for use in steam systems where indirect steam contacts food surfaces.
Refineries & Petrochemical Plants Protects boiler tubes and systems from corrosion and fouling due to contaminated feedwater.
Power Plants Enhances reliability and efficiency by keeping boiler internals clean.
Pharmaceutical Industry Assures consistent boiler operation in clean utility systems.
Textile & Paper Industry Prevents scale and sludge deposits that can affect heat exchanger performance.

Availability

Boiler Water Sludge Conditoner manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Surat, Gujrat, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Boiler Water Sludge Conditoner at a competitive price from us. We have ready stock of Boiler Water Sludge Conditoner in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches