RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,061 products across 71 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Lab Chemical

Electrode Storage Solution

DO NOT store your pH electrode in distilled or deionised water as this will cause ions to leach out of the glass membrane and reference electrolyte, causing a slow and sluggish response.
Part number
RXSOL-60-1711-020
Category
Lab Chemical
Brand
RXSOL
Electrode Storage Solution

Overview

DO NOT store your pH electrode in distilled or deionised water as this will cause ions to leach out of the glass membrane and reference electrolyte, causing a slow and sluggish response.

It is a solution prepared with reagent grade chemicals that that can be used to ensure optimum performance of  Electrode.The life  electrode is not infinite. A number of factors affect the life span of your  electrode. The higher the temperature that the electrode is used at, the more extreme , how often the bulb dries out and needs to be rehydrated, how roughly it is used; all these factors and more shorten the life span of your electrode. An   electrode
that is well maintained and cared for can last up to 2 years, one that is not well maintained will not last as long, and one that is well maintained will not last significantly longe.Electrode Storage Solution helps to keep your  electrodes corrosion free between uses. These solutions are easy-to-use.

This is special formulation to minimize microbial growth and osmotic / diffusion effect between the solution and inner reference electrolyte. Manufactured specifically for pH , ORP and other testing elctrodes.

Technical specifications

Physical Properties :

Appearance : Colorless liquid
Odor : Odorless
Density at 20 °C : 1.02 g/cm³
pH : 5-7
Boiling Point : > 100 °C
Flash Point : NA
Solubility : Complete soluble

Applications

Storage of the pH electrode when not in use :  The electrode bulb needs to be moist at all times. When you are done with the electrode pour, electrode storage solution into the cap that came with the electrode and put the cap over the bulb of the electrode. Keep the cap on until next use. If the electrode is being stored for a long time you may want to check the cap to be sure the storage solution is still in the cap and keeping the bulb moist. 

Rinsing the  electrode between measurements. You should rinse your  electrode between measurements. This can be done with distilled water or rinsing with a sample of the next solution to be measured. Using both distilled water and then a sample of the next solution is also a good way to rinse the  electrode between measurements.

pH electrode fill hole : Some  electrodes have a fill hole for refreshing the electrolyte in the  electrode; other  electrodes do not have a fill hole. If your electrode has a fill hole the fill hole cap should be removed during calibration and use. This allows for the correct amount of reference electrolyte to flow into the sample. Replace the fill hole cap when done with the electrode at the end of the day.

Dosage and directions

Immerse probe in Electrode Storage Solution, making sure entire probe stays submerged. After storage, rinse with clean tap water or distilled water before using. Store at room temperature between 20°C – 25°C. Clean the probe with Electrode Cleaning Solutions  before storage if probe has been immersed in several nutrient solutions without cleaning.

Characteristics and notes

DO NOT STORE THE pH ELECTRODE IN DISTILLED WATER. Storing the pH electrode in distilled water will shorten the life of your pH electrode. If you do not have electrode storage solution, temporary use pH 4 buffer solution.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name RXSOL-60-1711-020
Product Type Electrode Storage Solution

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA 

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
SARA 313 Component  CAS Number Percent Comp. Dimension
 
Exposure
 Limits
 
Potassium Chloride CAS# 7447-40-7   11.2% W/V  None
 established
 
Potassium Hydrogen Phthalate CAS# 877-24-7  

  0.51%

 W/V  TXDS: orl-rat LD•:
3200 mg/Kg
 
Water, Deionized ASTM Type II CAS# 7732-18-5 89.31%  V/V  None Established 

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.

 

SKIN:

Wash exposed area with soap and water. If irritation persists, seek
medical attention.

  EYES: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally.
Seek Medical Aid.
  INHALATION:

Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen

  INGESTION: If swallowed, induce vomiting immediately after giving two glasses of water. Never give anything by mouth to an unconscious person.

Fire Extinguisher Type:

Any means suitable for extinguishing surrounding fire

Fire / Explosion Hazards: None Known.
Fire Fighting Procedure: Wear self-contained breathing apparatus and protective
clothing to prevent contact with skin and clothing.

Absorb spill with inert material. Flush excess down drain.

Store in a cool dry place. This material is not considered hazardous. Handle using safe laboratory practices.

Respiratory Protection

None required

Ventilation  Local Exhaust 
OTHER Mechanical
Protective Gloves Gloves to prevent skin exposure as rubber or vinyl
EYE PROTECTION Splash Goggles
Other Protective Equipment Wear appropriate clothing to prevent
skin exposure
BOILING POINT Information  not available
VAPOR PRESSURE  Information  not available
MELTING POINT Information  not available
VAPOR DENSITY   Information not available
EVAPORATION RATE Information  not available
Appearance /Odors Clear, colorless, odorless liquid
Flash Point not flammable
Specific Gravity ~1.1
Percent Volatile by ~87
Evaporation Standard    
Auto Ignition Temp

Not applicable

Lower Flamm. Limit in Air

  Not applicable

Upper Flamm. Limit in Air  Not applicable
Solubility in Water  Soluble

STABILITY

Stable

CONDITIONS TO AVOID

None known 

MATERIALS TO AVOID

Bromine triflouride, potassium permaganate
plus sulfuric acid

HAZARDOUS DECOMPOSITION PRODUCTS

None known

HAZARDOUS POLYMERIZATION

Will Not Occur
Conditions to Avoid  None known

Imformation is not fund. 

Imformation is not fund. 

Imformation is not fund. 

DOT Classification: Not Regulated

DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations.

Imformation is not fund. 

Can also produce gastrointestinal irritaition and vomiting. May produce weakness and circulatory problems. Can also cause skin rash or eye irritation. Chronic: None found . Target organs: None. Persons with preexisting disorders may be more susceptible.

                                                              Flammability

Health                                                                                                      Reactivity

                                                                                      

Revisions

NFPA
10/20/2011  0.1 
  0     Creation date LS

The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material can be used safely.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Electrode Storage Solution manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Electrode Storage Solution at a competitive price from us. We have ready stock of Electrode Storage Solution in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches