Ethoxy Propanol
- Part number
- RXSOL-20-1561-184
- Category
- Tank Cleaner
- Brand
- RXSOL
Overview
Ethoxy propanol or ethoxypropanol or ethyl ether of propylene glycol is a colourless propylene glycol ether used as a solvent in resins, inks and adhesives.
Technical specifications
| CAS No of Ethoxy Propanol | 1569-02-4 |
|---|---|
| Chemical Formula of Ethoxy Propanol | C5H12O |
Applications
Dosage and directions
Ethoxy Propanol is a combustible liquid with low toxicity. It has a pleasant ether-like odor and is completely miscible with water and a number of organic solvents. It has excellent solvency for a wide variety of substances including resins, inks, and adhesives. Ethoxy Propanol can be used as a replacement for ethylene glycol (E-series) ethers and acetates.
Characteristics and notes
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | Ethoxy Propanol |
| Part Number | RXSOL-20-1561-184 |
Company Details:....
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Mumbai , Chennai, Vizag, Kolkata, UAE , OMAN , CANADA and KENYA
| Phone | +91 22 20871200 - 1400 |
| Fax | +91 22 27612100 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com | |
| Website | www.rxmraine.com |
Substances
| Formula | C5H12O2 |
| Molecular weight | 104,15 g/mol |
| CAS-No. | 1569-02-4 |
| Component | Classification | Concentration |
| 1-Ethoxy-2-propanol | ||
|
CAS-No. 1569-02-4
EC-No 216-374-5
Index-No. 603-177-00-8
|
Flam. Liq. 3; STOT SE 3;
H226, H336
|
<= 100 % |
For the full text of the H-Statements mentioned in this Section, see Section 16.
Classification of the substance or mixture
| Classification according to Regulation (EC) No 1272/2008 |
Flammable liquids (Category 3), H226
Specific target organ toxicity - single exposure (Category 3), Central nervous system, H336
For the full text of the H-Statements mentioned in this Section, see Section 16.
|
Label elements
| Signal Word | Warning |
|
Hazard Statements |
H226 Flammable liquid and vapor.
H336 May cause drowsiness or dizziness.
|
|
Precautionary Statements |
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof electrical/ ventilating/ lighting/ equipment.
P242 Use non-sparking tools.
P243 Take action to prevent static discharges.
|
| Supplemental Hazard Statements | None |
| Other hazards |
This substance/mixture contains no components considered to be either persistent,
bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at
levels of 0.1% or higher.
|
Description of first aid measures
| General advice | Show this material safety data sheet to the doctor in attendance. |
| If inhaled | After inhalation: fresh air. Call in physician. |
| In case of skin contact | In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. Call a physician immediately. |
| In case of eye contact | After eye contact: rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses. |
| If swallowed | After swallowing: make victim drink water (two glasses at most), avoid vomiting (risk of perforation). Call a physician immediately. Do not attempt to neutralise. |
| Most important symptoms and effects, both acute and delayed | The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11 |
| Indication of any immediate medical attention and special treatment needed | No data available |
Extinguishing media
| Suitable extinguishing media | Foam Carbon dioxide (CO2) Dry powder |
| Unsuitable extinguishing media | For this substance/mixture no limitations of extinguishing agents are given. |
| Special hazards arising from the substance or mixture |
Highly flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard.
In a fire or if heated, a pressure increase will occur and the container may burst, with the
risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along
the ground. Vapors may accumulate in low or confined areas or travel a considerable
distance to a source of ignition and flash back.
Highly flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard.
In a fire or if heated, a pressure increase will occur and the container may burst, with the
risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along
the ground. Vapors may accumulate in low or confined areas or travel a considerable
distance to a source of ignition and flash back.
Highly flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard.
In a fire or if heated, a pressure increase will occur and the container may burst, with the
risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along
the ground. Vapors may accumulate in low or confined areas or travel a considerable
distance to a source of ignition and flash back.
Carbon oxides
Combustible.
Vapors are heavier than air and may spread along floors.
Risk of dust explosion.
Forms explosive mixtures with air at elevated temperatures.
Development of hazardous combustion gases or vapours possible in the event of fire.
|
| Advice for firefighters |
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing. |
| Further information |
Remove container from danger zone and cool with water. Prevent fire extinguishing water from contaminating surface water or the ground water system.
spray to keep fire-exposed containers cool.Promptly isolate the scene by removing all persons from the vicinity of the incident if
there is a fire. No action shall be taken involving any personal risk or without suitable
training. Move containers from fire area if this can be done without risk. Use water
spray to keep fire-exposed containers cool.
|
| Personal precautions, protective equipment and emergency procedures | Advice for non-emergency personnel: Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert. For personal protection see section 8. |
| Environmental precautions | Do not let product enter drains. |
| Methods and materials for containment and cleaning up | Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up dry. Dispose of properly. Clean up affected area. Avoid generation of dusts. |
| Reference to other sections | For disposal see section 13. |
Precautions for safe handling
| Advice on safe handling | Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols. |
| Advice on protection against fire and explosion | Keep away from open flames, hot surfaces and sources of ignition.Take precautionary measures against static discharge. |
| Hygiene measures |
Change contaminated clothing. Wash hands after working with substance.
For precautions see section 2.2.
|
|
Conditions for safe storage, including any incompatibilities Storage conditions |
Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and sources of ignition. |
| Storage stability |
Recommended storage temperature
2 - 8 °C
|
| Storage class | Storage class (TRGS 510): 3: Flammable liquids |
| Specific end use(s) | Apart from the uses mentioned in section 1.2 no other specific uses are stipulated |
Control parameters
Ingredients with workplace control parameters
Exposure controls
Personal protective equipment
| Eye/face protection | Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles |
| Skin protection | Required |
| Body Protection | Flame retardant antistatic protective clothing. |
| Respiratory protection |
Required when vapours/aerosols are generated.Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Recommended Filter type: Filter type ABEK
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
|
| Control of environmental exposure | Do not let product enter drains. Risk of explosion. |
| Physical state | Liquid |
| Colour | No data available |
| Odor | No data available |
| Melting point/freezing point | Melting point/freezing point: < -70 °C at 1.013,25 hPa |
| Initial boiling point and boiling range | 130,5 - 134,5 °C at 1.013 hPa |
| Flammability (solid, gas) | Flammable aerosol. |
| Upper/lower flammability or explosive limits | No data available |
| Flash point | 38,5 °C |
| Autoignition temperature |
287 °C
at 101,3 h Pa
|
| Decomposition temperature | No data available |
| pH | No data available |
| Viscosity |
Viscosity, kinematic: 2,469 mm2/s at 20 °C
Viscosity, dynamic: 2,21 mPa.s at 20 °C
|
| Water solubility | No data available |
| Partition coefficient: n-octanol/water | log Pow: < 1 at 20 °C |
| Vapor pressure | 10 - 14 hPa at 34 - 56 °C |
| Density | 0,898 g/cm3 at 20 °C |
| Relative density | No data available |
| Relative vapor density | No data available |
| Particle characteristics | No data available |
| Explosive properties | No data available |
| Oxidizing properties | None |
| Other safety information | No data available |
| Reactivity | Vapor/air-mixtures are explosive at intense warming. |
| Chemical stability | The product is chemically stable under standard ambient conditions (room temperature) |
| Possibility of hazardous reactions | No data available |
| Conditions to avoid | Heating. |
| Incompatible materials |
Strong oxidizing agents
|
| Hazardous decomposition products | In the event of fire: see section 5 |
Information on toxicological effects
| Acute toxicity |
LD50 Oral - Rat - male and female - 1.792 mg/kg
(OECD Test Guideline 401)
LC50 Inhalation - Rat - male and female - 4 h - > 9,59 mg/l
(OECD Test Guideline 403)
LD50 Dermal - Rat - male and female - > 2.000 mg/kg
(Directive 67/548/EEC, Annex V, B.3.)
|
| Skin corrosion/irritation |
Skin - Rabbit
Result: Causes burns.
Remarks: (ECHA)
|
| sensitization | Not available |
| mutagenicity | Not available |
| Carcinogenicity | Not available |
| Reproductive toxicity |
Not available
|
| Teratogenicity | Not available |
| Specific target organ toxicity (single exposure) | Not available. |
| Specific target organ toxicity (repeated exposure) | Not available. |
| Aspiration hazard | Not available. |
| Information on the likely routes of exposure | Not available. |
| Persistence and degradability | No data available |
| Toxicity to fish | Static test LC50 - Oncorhynchus mykiss (rainbow trout) - 75 mg/l - 96 h (OECD Test Guideline 203) |
| Toxicity to daphnia and other aquatic invertebrates | Static test EC50 - Daphnia magna (Water flea) - 42,81 mg/l - 48 h (OECD Test Guideline 202) Remarks: (in analogy to similar products) The value is given in analogy to the following substances: maleic acid |
| Toxicity | Toxicity to fish LC50 - Pimephales promelas (fathead minnow) - 1.520 mg/l - 96 h |
| Toxicity to bacteria | EC10 - Bacteria - 14 mg/l - 72 h Remarks: (Lit.) EC5 - E.coli - 15.000 mg/l Remarks: (Lit.) (maximum permissible toxic concentration) |
| Toxicity to algae | Static test ErC50 - Pseudokirchneriella subcapitata (green algae) - 74,35 mg/l - 72 h (OECD Test Guideline 201) Remarks: (in analogy to similar products) The value is given in analogy to the following substances: maleic acid |
| Products Biodegradation | The methods for determining the biological degradability are not applicable to inorganic substances. |
| Mobility in soil | No data available |
| Results of PBT and vPvB assessment | This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher. |
| Endocrine disrupting properties | No data available |
| Other adverse effects | No data available . |
| Product | Offer surplus and non-recyclable solutions to a licensed disposal company. Waste material must be disposed of in accordance with the Directive on waste 2008/98/EC as well as other national and local regulations. Leave chemicals in original containers. No mixing with other waste. Handle uncleaned containers like the product itself. |
| Contaminated packaging | Dispose of as unused product. |
| Waste treatment Method | See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions. |
| UN number | ADR/RID:2404 IMDG:2404 IATA: 2404 |
| UN proper shipping name | ADR/RID:PROPIONITRILE IMDG:PROPIONITRILE IATA:PROPIONITRILE |
| Transport hazard class(es) | ADR/RID: 3 (6.1) IMDG: 3 (6.1) IATA:3 (6.1) |
| Packaging group | ADR/RID: II IMDG: II IATA:II |
| Environmental hazards | ADR/RID: No IMDG: No IATA: No |
| Special precautions for user | No data available |
| Further information | Not classified as dangerous in the meaning of transport regulations. |
| Safety, health and environmental regulations/legislation specific for the substance or mixture | This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006. |
| Other regulations | Observe work restrictions regarding maternity protection in accordance to Dir 92/85/EEC or stricter national regulations where applicable. Take note of Dir 94/33/EC on the protection of young people at work. |
| Chemical Safety Assessment | For this product a chemical safety assessment was not carried out |
| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and weassume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International has been advised of the possibility of such damages. DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable. |