RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,061 products across 71 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Lab Chemical

Fluoride Ion Solution 0.0100 Molar

Lab Reagent
Part number
RXSOL-60-6238-100
Category
Lab Chemical
Brand
RXSOL
Fluoride Ion Solution 0.0100 Molar

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name RXSOL-60-6238-100
Product Type Fluoride Ion Solution 0.0100 Molar

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com

       

SARA 313 Component  CAS Number Percent Comp. Dimension
 
Exposure
 Limits
 
Potassium Fluoride CAS# 13455-21-5
 
   9.413 W/V
 
   
Water, Deionized ASTM Type II  CAS# 7732-18-5  

  90.587

 V/V  None
 Established 

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.

Emergency Overview:POISON! DANGER! CORROSIVE. LIQUID AND MIST CAUSE
SEVERE BURNS TO ALL BODY TISSUE. MAY BE FATAL IF SWALLOWED. HARMFUL IF INHALED. INHALATION MAY CAUSE LUNG AND TOOTH DAMAGE. FLAMMABLE LIQUID AND VAPOR. CORROSIVE!

Inhalation:Inhalation of Vapors can cause Coughing, Choking, Inflammation, of the Nose, Throat, and Upper Respiratory Tract, and in Severe Cases, Pulmonary Edema, Circulatory Failure, and Death.

Ingestion:CORROSIVE! Swallowing can cause Immediate Pain and Burns of the Mouth, Throat, Esophagus, and Gastrointestinal Tract. May cause Nausea, Vomiting, and Diarrhea, and in Severe Cases, Death.

Skin:CORROSIVE! Can cause Redness, Pain, and Severe Skin Burns. Concentrated Solutions Cause Deep Ulcers and Discolor of Skin.

CORROSIVE! Vapors are Irritating and May cause Damage to Eyes. Contact May cause Severe Burns and Permanent Eye Damage.

Chronic Exposure:Eye Contact:Long-Term Exposure to Concentrated Vapors May cause Erosion of Teeth. Long-Term Exposures Seldom Occur due to the Corrosive Properties of the Acid.

Aggravated by Exposure:Persons with Pre-Existing skin Disorders or Eye Disease May be more Susceptible to the Effects of this Substance.

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling. 

 

SKIN:

Remove contaminated clothing. Wash exposed area with soap and
water. if irritation persists, seek medical attention.

  EYES: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally.
Seek Medical Aid.
  INHALATION:

Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen

  INGESTION: If swallowed, induce vomiting immediately after giving two glasses of water. Never give anything by mouth to an unconscious person.

Fire Extinguisher Type:

Any means suitable for extinguishing surrounding fire

Fire / Explosion Hazards: None
Fire Fighting Procedure: Wear self-contained breathing apparatus and protective
clothing to prevent contact with skin and clothing.

Dispose of in a manner consistent with federal, state and local regulations.

Ventilate Area of Leak or Spill. Keep Unnecessary and Unprotected People away from Area of of Spill. Wear Appropriate Personal Protective Equipment as Specified in Section 8. Contain and Recover Liquid when Possible. Collect Liquid in a Appropriate Container and Absorb with Dry Sand, Vermiculite, Earth or other Inert Substance and Package in a Suitable Container for Disposal. Do Not Flush to Sewer!

Store in a cool, dry, well-ventilated place away from incompatible materials.Wash thoroughly after handling.

Respiratory Protection

 NIOSH/MSHA-approved respirator

Ventilation
 
Local 
OTHER Mechanical
 
Protective Gloves NIOSH Approved Gloves
 
EYE PROTECTION Goggles and Face
Shield
Other Protective Equipment Wear appropriate clothing to prevent
skin exposure
BOILING POINT Information  not available
VAPOR PRESSURE  Information  not available
MELTING POINT Information  not available
VAPOR DENSITY   Information not available
EVAPORATION RATE Information  not available
Appearance /Odors Clear, colorless, odorless liquid
Flash Point not flammable
 
Specific Gravity Information  not available
Percent Volatile by ~94%
Evaporation Standard    
Auto Ignition Temp

Not applicable

Lower Flamm. Limit in Air

Not applicable

Upper Flamm. Limit in Air Not applicable
 
Solubility in Water  Soluble

STABILITY

Stable

CONDITIONS TO AVOID

Contact with incompatible materials
 

MATERIALS TO AVOID

Oxidizers, corrosives, quinine & calcium
salts

HAZARDOUS DECOMPOSITION PRODUCTS

Hydrogen fluoride gas
 

HAZARDOUS POLYMERIZATION

Will Not Occur
Conditions to Avoid  None known

 Carcinogenic References: IARC Category- None, NTP Carcinogen - Known: No

 No Information Found.

Waste must be disposed of in accordance with federal, state and local environmental control
regulations

DOT Classification: Not Regulated

DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations.

 All components are listed on TSCA inventory.

Conditions aggravated/target organs: Irritation to eyes, respiratory system. Severe irritation or burns to skin and eyes. May cause cyanosis and lung injury with 1-2 day delay. Overexposure may result in fluorosis. Ingestion may cause burns to GI tract. Target organs: Skin, eyes, respiratory tract, GI tract, bones, circulatory system, joints.

                                                              Flammability

Health                                                                                                      Reactivity

                                                                                              

Revisions

 NFPA
 
 7/30/2010  0.1  updated msds to 16 section from 10 section msds. STN
  0    

The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Fluoride Ion Solution 0.0100 Molar manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Fluoride Ion Solution 0.0100 Molar at a competitive price from us. We have ready stock of Fluoride Ion Solution 0.0100 Molar in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches