RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,082 products across 97 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Drilling Fluids & Mud Oil Field chemicals

Heat Transfer Glycol Liquid

Heat Transfer water mix propylene glycol liquid
Part number
RXSOL-81-1586-210
Brand
RXSOL
RXSOL

Overview

Propylene glycol inhibited with the corrosion inhibitor resulting corrosion protection, as well as efficient heat transfer, in water-based, closed-loop heating and air-conditioning systems.  RXSOL Corrosion Inhibited MPG is an engine coolant concentrate based on mono propylene glycol with high quality corrosion inhibitor. Also Antifreeze MPG does not contain nitrite, amine, phosphate, borate and silicates inhibition suitable for cooling systems of all types of internal combustion engines.

Heat Transfer Glycol is a specially formulated fluid designed for efficient thermal energy transfer in heating and cooling systems. It provides excellent freeze protection while ensuring stable heat conductivity across a wide temperature range. The formulation contains corrosion inhibitors to protect metal components from scaling and rust. It is chemically stable, non-volatile, and suitable for long-term use in closed-loop systems.
Commonly used in HVAC, industrial chillers, and process cooling applications, it ensures reliable and safe operation.

Technical specifications

Main Ingredients   : PROPYLENEGLYCOL (1,2-) 94%
Inhibitors and water
: 6 %
Colour Bright : Clear
pH of solution : 8.8
Odour            : PRACTICALLY ODOURLESS
Solubility in water        : SOLUBLE
     
Boiling point         : 162 oC
Freezing point       : -32 oC
Viscosity     : 58.1 cp at 20 oC
Reverse Alkalinity         : Minimm 15.0 ml
Vapour pressure    : .07 mbar at 20oC
Skin absorption/irritation       : YES
TLV       Country     :  
Pollution category    1994       : III
 

Applications

Glycol characteristic is to transfer heat from one place to other, due to that water-miscible glycol based coolant frequently used in heat transfer and cooling applications. Addition of Propylene Glycol in water enhances heat transfer parameters than water.

Dosage and directions

Dose : For corrosion protection, always use after dilution ration 30 to 52 volume percentage. Coolant Additive can be use after compatibility test or by manufacturer recommendation. 
This Inhibited Propylene glycol heat transfer fluid has an operating temperature range of -50°F to 325°F; with fluid freeze protection to below -60°F, and system burst protection to below -100°F. 
This fluid is specially formulated for HVAC systems to keep pipes free of corrosion without fouling.
This fluid is recommended for use in applications where low acute oral toxicity is important or where incidental contact with drinking water is possible.

Characteristics and notes

PROPYLENE GLYCOL supplier and exporter. Experts suggest in Airstack Chiller mixing of propylene glycol with water always be beneficial. Mixture in recirculating chillers is beneficial whenever the coolant temperature set point is below 10°C (48°F)

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet

Product Name RXSOL-81-1586-210
Product Type   Heat Transfer Liquid GLYCOL

Application : Most commonly use as Heat Transfer Liquid and Antifreeze

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Mumbai, Kandla, Chennai, Visakhapatnam, Kolkata, Fujairah, Muscat, Canada

Phone +91 22 65113333 / 5555 / 9999 / 27815540/41
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com

Chemical Name

CAS Number

EC Number

Percentage

Propane-1,2-Diol

57-55-6

200-338-0

6-9
Ethylene Glycol 107-21-1 203-473-3 35-40
Sodium 2-Ethylhexanoate
19766-89-3
243-283-8 3-5
Boron Mixture 1303-964 215-540-4 0.5-1.5

Hazard description: Not applicable.
Information concerning particular hazards for human and environment: Not applicable.

General information No special measures required.

After inhalation

Get medical attention if symptoms occur, Supply fresh air, consult doctor in case of complaints. On priority pass fresh air and keep at rest in a position comfortable for breathing. 

After skin contact

Generally the product does not irritate the skin. However Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

After eye contact

Rinse opened eye for several minutes under running water. Also Continue to rinse for at least 10 minutes. Get medical attention if furhter irritation occurs.

After swallowing

If symptoms persist consult doctor.

Suitable extinguishing agents: Use fire extinguishing methods suitable to surrounding conditions. Extinguishing media : : : Use dry chemical, CO₂, alcohol-resistant foam or water spray (fog). Suitable extinguishing media
Protective equipment: No special measures required.

Person-related safety precautions: Not required.
Measures for environmental protection:Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water.
Measures for cleaning/collecting: Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Additional information: No dangerous substances are released.

Handling:
 Information for safe handling:
 Handling:
 Information for safe handling: No special requirement
 Information about fire - and explosion protection: No special measures required.
Storage:
 Requirements to be met by storerooms and receptacles: No special requirements.
 Information about storage in one common storage facility: Not required.
 Further information about storage conditions: None.
 Information about fire - and explosion protection: No special measures required.
Storage:
 Requirements to be met by storerooms and receptacles: No special requirements.
 Information about storage in one common storage facility: Not required.
 Further information about storage conditions: None.

Additional information about design of technical facilities: No further data; see item 7.

Ingredients with limit values that require monitoring at the workplace:
57-55-6 propane-1,2-diol
WEEL (USA)
WEL (Great Britain)
10 mg/m³
474* 10** mg/m³, 150* ppm
*total vapour and particulates **particulates

Additional information: The lists valid during the making were used as basis.
Personal protective equipment:
General protective and hygienic measures:
The usual precautionary measures are to be adhered to when handling chemicals.
Respiratory protection: Not required.
Protection of hands: The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation
Material of gloves:The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and
varies from manufacturer to manufacturer.

Penetration time of glove material:The exact break through time has to be found out by the manufacturer of the protective gloves and has to be   observed.
Eye protection: Goggles recommended during refilling.

General Information

Form

Fluid - Liquid

Colour

Colourless

Odour

Nearly odourless

Change in condition

Freezing point/Melting range

-32°C

Boiling point/Boiling range

162°C

Flash point

> 100°C

Ignition temperature

371°C

Danger of explosion Product does not present an explosion hazard.
Explosion limits  
Lower 2.6 Vol %
Upper 12.6 Vol %
Vapour pressure at 20°C 0.11 hPa
Density at 20°C 1.0362 g/cm³
Solubility in / Miscibility with water Fully miscible.
pH-value (- g/l) 8.8
Viscosity
Dynamic at 25°C 46 mPas

Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.
Dangerous reactions No dangerous reactions known.
Dangerous decomposition products: No dangerous decomposition products known.

Acute toxicity:
LD/LC50 values relevant for classification:  

Oral

Dermal

LD50

LD50

2000 mg/kg (rat)

20800 mg/kg (rabbit)

Primary irritant effect:
on the skin No irritant effect.
on the eye No irritating effect.
Sensitization No sensitizing effects known.
Additional toxicological information:
When used and handled according to specifications, the product does not have any harmful effects to our experience and the information provided to us.
The substance is not subject to classification according to the latest version of the EU lists.

General notes: Water hazard class 1 (German Regulation) (Assessment by list): slightly hazardous for water Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.

Product:
Recommendation Smaller quantities can be disposed of with household waste.
Uncleaned packaging:
Recommendation: Disposal must be made according to official regulations.
Recommended cleansing agents: Water, if necessary together with cleansing agents.

Land transport ADR/RID (cross-border)
ADR/RID class: -
Maritime transport IMDG:
IMDG Class: -
Marine pollutant: No
Air transport ICAO-TI and IATA-DGR:
ICAO/IATA Class: -

Labelling according to EU guidelines:
Observe the general safety regulations when handling chemicals.
The substance is not subject to classification according to EU lists and other sources of literature known to us.

This information is based on our present knowledge.However, this shall not constitute a guarantee for anys pecific product features and shall not establish a legally valid contractual relationship.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

MPG Antifreeze Heat Transfer Liquid manufacturer and supplier in India Mumbai, Chennai, Kolkata, Visakhapatnam, Gandhidham, Surat, UAE Middle East Fujairah, Ajman, Abudhabi, Sharjah, Dubai  Oman Muscat Barka Ruwi Sohar CANADA, Qatar, Sudan, Yemen, Nairobi Kenya

Our stock points and branches