Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | High pH Indicator Solution |
| Product Type | RXSOL-60-6229-100 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
| Phone | +91 22 65113333 / 5555 / 9999 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com |
| SARA 313 Component | CAS Number | Percent Comp. |
Dimension |
Exposure Limits |
| 1,2-Propanediol(Propylene Glycol) | CAS# 57-55-6 20 |
20-30% |
V/V | |
| N-Propoxy Propanol Prop Glycol Propyl Ether | CAS#1569- | 10 - 15% | V/V | OSHA TWA Ether 1000 ppm(2400 mg/mƒ) |
| Orange G (Acid Orange | CAS# 1936-15-8 | 0.05-0.5% | w/V | None Established |
| Water, Deionized ASTMType II | CAS# 7732-18-5 | Balance | V/V | None Established |
Keep away from heat and ignition sources. Harmful if swallowed. Avoid breathing vapors. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling. Keep container
Emergency Overview:Danger! Harmful If Swallowed Or Inhaled. Causes Irritation To Skin And Eyes. Causes Irritation To Respiratory Tract.
Inhalation:Exposure may Cause Irritation to the Mucous Membranes of the Upper Respiratory Tract. Proloned Exposures to High Concentrations may Cause Drowsiness, Loss of Appetite and Inability to Concentrate and Possibly Death.
Ingestion:Can Cause Headaches, Gastritis, Intoxication, Blindness and in Acute Cases, Death.Cathartic. Very Active, even in Small Amounts (30 - 100 mg). May Cause Purging, Collapse, and Fall in Blood Pressure or an Itching Skin Rash that can Become Ulcerous. Other Systemic Effects are Not Well Known.
Skin: tCan Cause Skin Irritation, Cracking, or Flaking due to Dehydration and Defatting Action.May be Absorbed Through the Skin with Possible Systemic Effects.
Eye ContactVapors Cause Eye Irritation. Splashes Cause Severe Irritation, Possible Corneal Burns and
Permanent Eye Damage.
Chronic Exposure:Prolonged Skin Contact Causes Drying and Cracking of Skin. May Effect Nervous System. May Affect Liver, Blood and Reproductive System.
Aggravated by Exposure:Persons with Pre-Existing Skin Disorders or Eye Problems or Impaired Respiratory Function, or Impaired Liver or Kidney Function may be More Susceptible to the Effects of this Agent.
Keep away from heat and ignition sources. Harmful if swallowed. Avoid breathing vapors. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling. Keep container closed..
|
SKIN: |
Remove contaminated clothing. Wash exposed area with soap and water. if irritation persists, seek medical attention. |
| EYES: | Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally.Seek Medical Aid. |
| INHALATION: | Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen |
| INGESTION: | Give several glasses of milk or water. Vomiting may occur spontaneously, but DO NOT INDUCE! Never give anything by mouth to an unconscious person. |
|
Fire Extinguisher Type: |
Alcohol Resistant Foam or Carbon Dioxide, water may be ineffective. |
| Fire / Explosion Hazards: | None |
| Fire Fighting Procedure: | Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and clothing. |
Ventilate area. Absorb spill with inert material, then place in a chemical waste container. Dispose of in a manner consistent with federal, local law.
Ventilate area or Leak or Spill. Remove all Sources of Ignition.Wear Appropriate Personal Protective Equipment as Specified in Section 8. Isolate Hazard Area. Keep Unnecessary and Unprotected Personnel from Entering. Contain and Recover Liquid when Possible. Use Non-Sparking Tools and Equipment. Collect Liquid in an Appropriate Container or Absorb with anInert Material (e.g., Vermiculite, Dry Sand, Earth), and Place in a Chemical Waste Container. Do Not Use Combustible Materials, such as Saw Dust. Do Not Flush to Sewer! US Regulations (CERCLA) Require Reporting Spills and Releases to Soil, Water and Air in Excess of Reportable Quantities.
Store in a cool dry place. Do not get in eyes, on skin, on clothing. Wash thoroughly after handling. Protect
from physical damage and where a fire hazard may be acute. Do not pressurize, cut, weld braze drill or expose containers to heat sparks or flame..
|
Respiratory Protection |
None required |
| Ventilation | Local |
| OTHER | Mechanical |
| Protective Gloves | Gloves to prevent skin exposure as rubber or vinyl |
| EYE PROTECTION | Splash Goggles |
| Other Protective Equipment | Wear appropriate clothing to prevent skin exposure |
| BOILING POINT | 370.4° F(188° C) |
| VAPOR PRESSURE | not available |
| MELTING POINT | information not available |
| VAPOR DENSITY | 2.62 |
| EVAPORATION RATE | information not available |
| Appearance /Odors | orange liquid, slight alcohol odor |
| Flash Point |
Not applicable |
| Specific Gravity |
Information not available |
| Percent Volatile by | |
| Evaporation Standard | not available |
| Auto Ignition Temp |
699.8° F (371° C) |
| Lower Flamm. Limit in Air |
Not applicable |
| Upper Flamm. Limit in Air |
Not applicable |
| Solubility in Water | Soluble |
|
STABILITY |
Stable |
|
CONDITIONS TO AVOID |
High temperatures, Light |
|
MATERIALS TO AVOID |
Halides, Ammonia, Phospahtes |
|
HAZARDOUS DECOMPOSITION PRODUCTS |
oxides of carbon, nitrogen |
|
HAZARDOUS POLYMERIZATION |
will not occur |
| Conditions to Avoid | None known |
Carcinogenic References: NTP Carcinogen - Known: No, IARC Category- 3
When Released to the Soil and Water, this Material may Evaporate to Moderate Extent. When Released into the Soil, This Material may Leach into Groundwater. When Released into the Water, This Material is Expected to have a Half Life Between 1 and 10 Days.
Whatever Cannot be Saved for Recovery or Recycling Should be Managed in an Appropriate and Approved Waste Disposal Facility. Processing, use or Contamination of this Product may Change the Waste Management Options. State and Local Disposal Regulation may Differ from Federal Disposal Regulations. Dispose of Container and Unused Contents in Accordance with Federal, State and Local Requirements.
DOT Classification: Not Regulated
DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations..
The ingredients of this product are listed on the TSCA Inventory.
Conditions aggravated/target organs: Persons with pre-existing skin, eye or respiratory disorders are more susceptible. Overexposure symptoms. Acute: irritation to skin, eyes, mucous membranes, and
GI tract. Effects of overexposure. Acute and chronic: Harmful by inhalation, ingestion, skin absorption. May cause eye and skin irritaition and central nervous system problems. May cause GI disturbances, nausea, headache and vomiting. Target organs:
None. Persons with pre-existing disorders may be more susceptible.
Flammability
Health Reactivity
|
Revisions |
NFPA |
| 7/28/2010 | 0.1 updated msds to 16 section from 10 section msds. STN |
| 10/10/2011 | 0.2 Removed Tropaeolon LS |
The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.
Availability
High pH Indicator Solution manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of High pH Indicator Solution at a competitive price from us. We have ready stock of High pH Indicator Solution in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.