Iron Sulfide Detection Solution
- Part number
- RXSOL-60-6259-500
- Category
- Lab Chemical
- Brand
- RXSOL
Overview
This test kit contains all of the supplies, equipment and instructions necessary to test steel armor wire (and other steel objects) for the presence of iron sulfide, which can be indicative of exposure to hydrogen sulfide.
Applications
-
Perform test in a well-ventilated area
-
Wear gloves, goggles, and mask
-
H₂S gas is toxic — avoid inhalation
-
Do not perform near ignition sources
Characteristics and notes
Warranty RXSOL Company warrants only title to the equipment, products and materials supplied and that the same are free from defects in workmanship and materials for one year from date of delivery.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED OF MERCHANTABILITY, FITNESS OR OTHERWISE BEYOND THOSE STATED IN THE IMMEDIATELY PRECEDING SENTENCE. RXSOL's sole liability and Customer's exclusive remedy in any cause of action (whether in contract, tort, breach of warranty or otherwise) arising out of the sale, lease or use of any equipment, products or materials is expressly limited to the replacement of such on their return to Fann or, at RXSOL's option, to the allowance to Customer of credit for the cost of such items. In no event shall RXSOL be liable for special, incidental, indirect, consequential or punitive damages. Notwithstanding any specification or description in its catalogs, literature or brochures of materials used in the manufacture of its products, Fann reserves the right to substitute other materials without notice. RXSOL does not warrant in any way equipment, products, and material not manufactured by RXSOL, and such will be sold only with the warranties, if any, that are given by the manufacturer thereof. RXSOL will only pass through to Customer the warranty granted to it by the manufacturer of such items.
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | RXSOL-60-6259-500 |
| Product Type | Iron Sulfide Detection Solution |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
| Phone | +91 22 65113333 / 5555 / 9999 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com |
| SARA 313 Component | CAS Number | Percent Comp. |
Dimension |
Exposure Limits |
| Hydrochloric Acid | CAS# 7647-01-0 | ~40% | V/V |
OSHA PEL (C) |
| Sodium m-Arsenite | CAS#: 7784-46-5 | 1.5% | W/V |
OSHA PEL 0.01 mg (As)/M3 ACGIH TLV: TWA 0.2 |
| Water, Deionized ASTM Type II | CAS# 7732- 18-5 | Balance | V/V |
None Established |
Causes severe irritation and burns. May be harmful if swallowed. Avoid breathing vapor or dust. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling. Keep container closed.
Emergency Overview: Danger! May Be Fatal if Swallowed or Inhaled. Cancer Hazard. Contains Inorganic Arsenic Which Can Cause Cancer. Risk of Cancer Depends on Duration and Level of Exposure.
Inhalation: CORROSIVE! Inhalation of Vapors can cause Coughing, Choking, Inflammation, of the Nose, Throat, and Upper Respiratory Tract, and in Severe Cases, Pulmonary Edema, Circulatory Failure, and Death.
Ingestion: CORROSIVE! Swallowing Hydrochloric Acid can cause Immediate Pain and Burns of the Mouth, Throat, Esophagus, and Gastrointestinal Tract. May cause Nausea, Vomiting, and Diarrhea, and in Severe Cases, Death.
Skin: CORROSIVE! Can cause Redness, Pain, and Severe Skin Burns. Concentrated Solutions Cause Deep Ulcers and Discolor of Skin.
Eye Contact: CORROSIVE! Vapors are Irritating and May cause Damage to Eyes. Contact May cause Severe Burns and Permanent Eye Damage.
Chronic Exposure: Long-Term Exposure to Concentrated Vapors May cause Erosion of Teeth. Long-Term Exposures Seldom Occur due to the Corrosive Properties of the Acid.
Aggravated by Exposure: Persons with Pre-Existing skin Disorders or Eye Disease May be more Susceptible to the Effects to this Substance.
Causes severe irritation and burns. May be harmful if swallowed. Avoid breathing vapor
or dust. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash
thoroughly after handling. Keep container closed.
|
SKIN: |
In case of contact, immediately flush skin with water for at least 15 |
|
| EYES: |
Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally. Seek Medical Aid. |
|
| INHALATION: |
Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen |
|
| INGESTION | Give several glasses of milk or water. Vomiting may occur spontaneously, but DO NOT INDUCE! Never give anything by mouth to an unconscious person. |
|
Fire Extinguisher Type: |
Any means suitable for extinguishing |
| Fire / Explosion Hazards: | may release toxic fumes of arsenic in a fire. |
| Fire Fighting Procedure: |
Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and clothing. |
Absorb spill with inert material, then place in a chemical waste container. Dispose of in a manner consistent with federal, local law.
Ventilate area of Leak or Spill. Wear Appropriate Personal Protective Equipment as Specified in Section 8. Isolate Hazard Area. Keep Unnecessary and Unprotected Personnel from Entering. Contain and Recover Liquid when Possible. Neutralize with Alkaline Material (Soda- Ash, Lime), then Absorb with an Inert Material (e.g., Vermiculite, Dry Sand, Earth), and place in a Chemical Waste Container. Do Not Use Combustible Materials, such as Saw Dust. Do Not Flush to Sewer! US Regulations (CERCLA) Require Reporting Spills and Releases to Soil, Water and Air in Excess of Reportable Quantities.
Store in a cool dry place. Do not get in eyes, on skin,on clothing. Wash thoroughly after handling
|
Respiratory Protection |
NIOSH approved dust mask |
| Ventilation | Local |
| OTHER | Mechanical |
|
Protective Gloves |
Gloves to prevent skin exposure as rubber or vinyl |
| EYE PROTECTION | Splash Goggles |
| Other Protective Equipment |
Wear appropriate clothing to prevent skin exposure |
| BOILING POINT | ~100° C |
| VAPOR PRESSURE | not available |
| MELTING POINT | ~0° C |
| VAPOR DENSITY | not available |
| EVAPORATION RATE | Information not available |
| Appearance /Odors | colorless odorless liquid |
| Flash Point | not flammable |
| Specific Gravity | Information not available |
| Percent Volatile by | >98% |
| Evaporation Standard | |
| Auto Ignition Temp |
Not applicable |
| Lower Flamm. Limit in Air |
Not applicable |
| Upper Flamm. Limit in Air | Not applicable |
| Solubility in Water | Soluble |
|
STABILITY |
Stable |
|
CONDITIONS TO AVOID |
Temperature extremes, incompatibilities |
|
MATERIALS TO AVOID |
Tannic acid, iron solutions, fluorine, |
|
HAZARDOUS DECOMPOSITION PRODUCTS |
Releases toxic fumes of arsenic when |
|
HAZARDOUS POLYMERIZATION |
not expected to occur |
| Conditions to Avoid | None known |
Carcinogenic References: Hydrogen Chloride - IARC Category 3, NTP Carcinogen - Known:
No
Sodium Arsenite - IARC Category 1, NTP Carcinogen - Known: Yes
Environmental Fate: No Information Found.
Environmental Toxicity: This material is expected to be toxic to aquatic life.
Whatever cannot be saved for recovery or recycling should be handled as hazardous waste and sent to a RCRA approved waste facility. Processing, use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements.
DOT Classification: UN2922, Corrosive Liquid, Toxic, n.o.s.
(Hydrochloric Acid, Sodium Arsenite), 8,
DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations.
Chemical Inventory Status –
Part 1:Ingrdient
Hydrogen Chloride (7647-01-0)
Sodium Arsenite (7784-46-5)
TSCA Yes YES
EC Yes YES
Japan YES YES
Australia Yes YES
Chemical Inventory Status –
Part 2:Ingredient
Hydrogen Chloride (7647-01-0)
Sodium Arsenite (7784-46-5)
Korea Yes YES
DSL Yes YES
NDSL No NO
Phil. Yes YES
Federal, State & International Regulations –
Part 1: Ingredient.
Hydrogen Chloride (7647-01-0)
Sodium Arsenite (7784-46-5)
RQ 5000 1
TPQ 500 500
List LIST NO
Chemical Catg No ARSNIC COMP
Federal, State &
International Regulations –
Part 2:Ingredient
Hydrogen Chloride (7647-01-0)
Sodium Arsenite (7784-46-5)
CERCLA 5000 1
261.33 No NO
8(d) No NO
Chemical Weapons Convention: No
TSCA 12 (b):No
CDTA:No MIXTURE/LIQUID
SARA 311/312: Acute:YES
Chronic: YES
Fire: No
Pressure: No
Reactivity: No
Poison Schedule:S5
DANGER! CARCINOGEN! CORROSIVE! Effects of exposure Acute and chronic: Inhalation: inflammationof mucous membranes, cough, dyspnea, cyanosis, Oral: May cause burning, vomiting, nausea, bloody diarrhea, low blood pressure, coma, death. Skin contact: May cause irritation, pain, dermatitis. Eye contact may cause redness, irritation, pain, conjunctivitis.Target Organs: liver, kidneys. Persons with existing skin, eye, kidney or liver problems may be more susceptible. Corrosive! Persons with preexisting skin, eye and respiratory disorders may be more susceptible. Acute: Severe irritation or burns to skin, eyes, respiratory tract and
Flammability
Health Reactivity
|
Revisions |
NFPA |
| 0 | |
| 7/30/2010 | 0.1 updated msds to 16 section from 10 section msds. STN |
The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.
Availability
Iron Sulfide Detection Solution manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Iron Sulfide Detection Solution at a competitive price from us. We have ready stock of Iron Sulfide Detection Solution in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.