RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,082 products across 98 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Tank Cleaner

Lead Cleaner/ Inhibitor Remover

very effective to clean and upgrade cargo tanks that have carried leaded gasoline, carbon tetrachloride and virgin naphtha.
Part number
RXSOL-20-2038-210
Category
Tank Cleaner
Brand
RXSOL
Lead Cleaner/ Inhibitor Remover

Overview

Presence of Lead content in petroleum product contaminant tank for next voyage,  RXSOL Lead Cleaner / Inhibitor Remover is a special and concentrated clear organic, Surfactant basis liquid compound which is very effective to clean and upgrade cargo tanks that have carried leaded gasoline, carbon tetrachloride and virgin naphtha.

RXSOL Lead Cleaner/Inhibitor Remover contains hydrocarbon acids, which has an excellent property to bind lead-ions and keep them in solutions.

Technical specifications

PH

:

6-7

Apperance

:

Clear Liquid

Specific Gravity

:

1:0

Cold stability

:

10°C

Solubility in Water

:

100% Soluble

Applications

RXSOL Lead Cleaner/Inhibitor Remover having very good bonding and emulsification power which provides a fast, efficient and economical method to remove lead and chlorides from the pores of zinc silicate , epoxy based coated tank surfaces or stain steel Tank.

Dosage and directions

Procedure of Use

Method - 1.

  • After discharging wash the tanks with warm sea water approx. 50 °C through butter wash Machines.
  • Ventilate tanks till “gas free”
  • Spray tanks with our undiluted Rxsol Lead Cleaner/Inhibitor Remover by spray gun and leave to soak for approx. 30 minutes.
  • 1 ltr of Rxsol Lead Cleaner/ Inhibitor Remover will clean 5 to 7 square meters of tank surface.
  • Start recirculation by butter worthing with warm water (preferable fresh) at 50°C through Machines for approx. 2 hours also through lines and manifold.
  • Finish tank washing by flushing with fresh water
  • Tanks to be mopped and dried.

Method 2

  • After discharging wash tanks with warm sea water approx 50ºC through butter wash machines .
  • Make solution 3 to 5% with Rxsol Lead Cleaner / Inhibitor Remover and warm sea water approx 60 to 70ºC and start recirculation by butter Worthing approx 2 hours also through lines and manifold
  •  Finish Tank cleaning by flushing with fresh water our sea water. Tanks be mopped and dried.

Characteristics and notes

This material is biodegradable  quickly. The total of the organic substances contained in the product reach, if finely dispersed, at least 60% BOD28/COD in the closed bottle test or at least 70% DOC removal in the modified OECD Screening test. (OECD-limits for classification "readily biodegradable": at least 60% BOD28/COD resp. at least 70% DOC.)

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet

Product Name RXSOL-20-2038-210
Product Type LEAD CLEANER / INHIBITOR REMOVER

 Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock : Mumbai, Kandla, Kolkata, Chennai, Visakhaptanam, Fujairah, Muscat, Nairobi

Phone +91 22 65113333 / 5555 / 9999 / 27611360
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com

Chemical Name

Concentration

CAS Number

EC Number

R Phrases*

Symbols

FattyAlcohol Ethoxylate

10-15

34398-01-1

500-084-3

41

Xi

2-,2(butoxyethoxy)ethanol

20-30

112-34-5

203-961-6

36

Xi

*See Section 16

Chemical characterization

Description

Mixture of substances listed below with nonhazardous additions. Cleansing agent

Dangerous components 

non-ionic surfactants Xn, Xi; R 22-41 10-25 % CAS: 111-76-2

Einecs

203-905-0 2-butoxyethanol Xn, Xi; R 20/21/22-36/38 2.5-10%

General Information

Immediately remove any clothing soiled by the product. Symptoms of poisoning may even occur after several hours; therefore medical observation for at least 48 hours after the accident.

After inhalation

Supply fresh air; consult doctor in case of complaints.

After skin contact

Generally the product does not irritate the skin.

After eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

After swallowing

Call for a doctor immediately

Suitable extinguishing agents

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Protective equipment

No special measures required.

Person-related safety precautions

Wear protective clothing.

Measures for environmental protectio

Dilute with plenty of water.

Do not allow to enter sewers/ surface or ground water.

Measures for cleaning/collecting

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).Dispose contaminated material as waste according to item 13.Ensure adequate ventilation.Dispose Of The Material Collected According To Regulations.

Handling

Information for safe handling

Store in cool, dry place in tightly closed receptacles..Prevent formation of aerosols.

Information about fire- and explosion protection

No special measures required.

Storage

Requirements to be met by storerooms and receptacles

No special requirements.

Information about storage in one common storage facility

Not required.

Further information about storage conditions

None.

Additional information about design of technical facilities: No further data; see item 7.
• Ingredients with limit values that require monitoring at the workplace:
111-76-2 2-butoxyethanol
WEL    Short-term value: 50 ppm
Long-term value            : 25 ppm
• Additional information : The lists valid during the making were used as basis.
• Personal protective equipment:
• General protective and hygienic measures: Keep away from foodstuffs, beverages and feed.
• Respiratory protection : Not required.
• Protection of hands     : Protective gloves
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
• Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.
• Penetration time of glove material
The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
• Eye protection   : Safety glasses
• Body protection : Protective work clothing

General Information

Form

Fluid

Colour 

 Clear

Odour

Characteristic

• Change in condition

Melting point/Melting range

Undetermined.

Boiling point/Boiling range

171°C

• Ignition temperature

240°C

• Self-igniting

Product is not selfigniting.

• Danger of explosion

Product does not present an explosion hazard.

• Explosion limits

Lower

1.1 Vol %

Upper

10.6 Vol %

• Vapour pressure at 20°C

23 hPa

• Density at 20°C

1.01 g/cm³

• Solubility in / Miscibility with

water

Fully miscible.

• pH-value at 20°C

> 7

Thermal decomposition / conditions to be avoided

No decomposition if used according to specifications.-

Dangerous reactions No dangerous reactions known.

Dangerous decomposition products

Carbon monoxide and carbon dioxide.

Acute toxicity

Primary irritant effect:

on the skin

No irritant effect.

on the eye

No irritating effect.

Sensitization

No sensitizing effects known.

Additional toxicological information

The product shows the following dangers according to the calculation method of the General EU

Classification Guidelines for Preparations as issued in the latest version

Harmful

General notes

Water hazard class 2 (German Regulation) (Self-assessment): hazardous for water.Do not allow product to reach ground water, water course or sewage system..Danger to drinking water if even small quantities leak into the ground.

Product Recommendation

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

Uncleaned packaging Recommendation

Disposal must be made according to official regulations.

Recommended cleansing agents

Water, if necessary together with cleansing agents.

• Land transport ADR/RID (cross-border)
• ADR/RID class : -
• Maritime transport IMDG:
• IMDG Class : -
• Marine pollutant  : No
• Air transport ICAO -TI and IATA-DGR :
• ICAO/IATA Class : -

Labelling according to EU guidelines

The product has been classified and marked in accordance with EU Directives / Ordinance on Hazardous Materials.

Code letter and hazard designation of product

Xn Harmful

Risk phrases

22 Harmful if swallowed.

Safety phrases

23 Do not breathe gas/fumes/vapour/spray (appropriate wording to be specified by the manufacturer). 26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. 36/37/39 Wear suitable protective clothing, gloves and eye/face protection. 60 This material and its container must be disposed of as hazardous waste.

National regulations

Waterhazard class

Water hazard class 2 (Self-assessment): hazardous for water.

This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship. • Relevant R-phrases. 20/21/22 Harmful by inhalation, in contact with skin and if swallowed..22 .Harmful if swallowed. 36/38     Irritating to eyes and skin. 41 Risk of serious damage to eyes.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Lead Cleaner/ Inhibitor Remover manufacturer and supplier in Mumbai, Gandhidham, Kolkata, Chennai, Visakhapatnam, Fujairah Dubai, Ajman, Abudhabi, Sharjah, Muscat Barka Oman, Nairobi, Kenya Africa

Our stock points and branches