Floor Care (Polish / Cleaner )
Masonry Brick Cleaner
- Part number
- RXSOL-13-1048-025
- Category
- Floor Care (Polish / Cleaner )
- Brand
- RXSOL
Overview
RXSOL-13-1048-025 Masonry Brick Cleaner,is a professional inhibited acidic masonry cleaner. Acid masonry cleaners are established for removing mortar/cement residues, efflorescence and mineral deposits, but overly strong acid can attack mortar and certain masonry, so the application instructions need proper dilution and surface testing.
MASONRY BRICK CLEANER
Product Code: RXSOL-13-1048-025
DESCRIPTION
RXSOL Masonry Brick Cleaner is a powerful, fast-acting acidic cleaner specially formulated for the removal of mortar residues, cement deposits, lime deposits, efflorescence, rust stains, mineral scale and construction-related staining from brickwork and masonry surfaces.
The product combines powerful acid cleaning action with wetting agents and corrosion-inhibiting components to penetrate stubborn mineral deposits and rapidly loosen cementitious contamination from the surface.
Its concentrated formulation allows the product to be diluted according to the severity of contamination, making RXSOL Masonry Brick Cleaner suitable for both heavy-duty post-construction cleaning and general masonry maintenance.
Technical specifications
TYPICAL PROPERTIES
| Property | Typical Value |
|---|---|
| Appearance | Clear to pale yellow liquid |
| Nature | Acidic cleaner |
| Solubility | Completely miscible with water |
| pH | Strongly acidic |
| Specific Gravity | Approx. 1.05–1.15 at 25°C* |
| Odour | Characteristic acidic odour |
| Application | Masonry, brick and construction cleaning |
| Dilution | Typically 1:1 to 1:20 depending upon application |
*Final specification should be based on production QC/formulation.
Typical descaling cleaning procedure :
1st Stage : Take ‘RXSOL-11-1053-010’ weblink ( http://rxmarine.com/Alkaline-Descaler ) and mix with water in the ratio of 1:6 (One litre of RXSOL-1053 and six litres of water). Circulate the solution or immerse the equipment in this solution for 2 hrs. This will be helpful in loosening the hard deposited scale.
Applications
SPECIAL FEATURES
-
Fast-acting masonry and brick cleaning formulation.
-
Rapidly attacks cement, mortar and lime-based deposits.
-
Helps remove rust stains and mineral discoloration.
-
Effective against efflorescence and construction residue.
-
Powerful wetting action improves penetration into stubborn deposits.
-
Inhibited acid formulation provides better control than the use of untreated mineral acid alone.
-
Reduces the need for excessive mechanical scrubbing.
-
Concentrated product for economical dilution with water.
-
Suitable for professional construction, industrial and maintenance applications.
-
Easy to apply by acid-resistant brush or low-pressure chemical sprayer.
OUTSTANDING PROPERTIES
RXSOL Masonry Brick Cleaner provides a combination of strong chemical cleaning and excellent surface penetration.
The active acidic components react with cementitious and mineral deposits, helping break down and loosen deposits so that they can be removed by thorough water rinsing.
The incorporated wetting system improves contact between the cleaner and contaminated surface, particularly on porous masonry.
The product is supplied as a concentrate, allowing the operator to adjust cleaning strength according to the type of substrate and severity of contamination.
USE FOR
RXSOL Masonry Brick Cleaner is recommended for cleaning:
-
Brickwork
-
Clay bricks
-
Masonry walls
-
Concrete surfaces*
-
Cementitious surfaces*
-
Paving blocks
-
Sandstone and compatible natural stone*
-
Building façades
-
Construction equipment
-
Cement and mortar contaminated tools
-
Acid-resistant tiles and surfaces
Effective Against
-
Mortar residue
-
Cement splashes
-
Cement film
-
Lime deposits
-
Efflorescence
-
Mineral deposits
-
Rust and iron staining
-
Construction dirt
-
Plaster residue
-
Scale deposits
-
General inorganic staining
*Compatibility testing is essential before use.
RXSOL-13-1048-025
MASONRY BRICK CLEANER
Fast-Acting Inhibited Acid Cleaner for Brick, Masonry & Construction Residues
One important change from the Corium wording: I would not publish “will not harm most finishes or damage paint coatings.” That's too broad for an acidic masonry cleaner. Even commercial brick-cleaner documentation warns about acid-sensitive stone, decorative surfaces, metals and possible masonry damage.
Also, your existing RXSOL masonry-cleaner material already uses the professional approach of pre-wetting, controlled dilution, short contact time and thorough rinsing, so this positioning is consistent with the RXSOL range. (Rx-Sol)
Dosage and directions
DIRECTIONS FOR USE
1. Surface Preparation
Remove loose dirt, dust and heavy pieces of mortar mechanically before chemical cleaning.
Thoroughly pre-wet the masonry surface with clean water, particularly when treating porous brickwork.
Protect adjacent surfaces, vegetation and equipment that may be sensitive to acidic cleaners.
2. Dilution
The optimum dilution should always be established by carrying out a small test area first.
| Cleaning Requirement | Recommended Starting Dilution |
|---|---|
| Heavy mortar / cement deposits | 1 part product : 1–2 parts water |
| Heavy construction residue | 1 : 2–3 |
| Normal masonry cleaning | 1 : 3–5 |
| Efflorescence / mineral staining | 1 : 5–10 |
| Light cleaning / maintenance | 1 : 10–20 |
Start with the weaker recommended concentration and increase strength only when necessary.
Always add the cleaner slowly to water. Never add water into concentrated acidic cleaner.
3. Application
Apply the diluted solution evenly using an acid-resistant brush or low-pressure chemical sprayer.
Allow sufficient time for the product to react with the contamination.
Visible bubbling or reaction may occur when the cleaner contacts cementitious or carbonate-containing deposits.
Do not allow the cleaning solution to dry on the surface.
For stubborn contamination, light agitation with an acid-resistant brush may be used.
4. Rinsing
After cleaning, rinse the treated surface thoroughly with large quantities of clean water.
Ensure that loosened deposits and residual cleaning chemical are completely removed.
A second treatment may be applied where exceptionally heavy deposits remain.
Characteristics and notes
• Automotive - Closed Circuit Cooling, Dynamometers, Extruders, Molders, Radiators, Welders
• Bottling - CO2 Generators, Heaters, Exchangers, Rinse Tanks, Sterilizers, Washers
. HOUSE HOLD - Dissolves hard and old lime scale deposits from your appliances. It extends the life of the appliance and saves running cost. It can be used in appliances such as Washing Machines, Dish Washers, Geysers, Steam Iron, Coffee Makers, Bath Tubs, Bathroom Fixtures etc.
• Buildings - Chillers, Cooling Towers, Pipework
• Chemicals - Dryers, Extruders, Kettles, Mixers, Reactors, Scrubbers, Vacuum Pumps
• Food - Condensers, Ice Machines, Kathabars, Refrigeration Equipment, Steam Tables
• Manufacturing - Chillers, Compressors, Furnaces, Quenchers, Vacuum Pumps
• Metals - Bearings, Castings, Fans, Hearth & Vacuum Furnaces, Shelters, Sprays
• Mining - Bearings, Conveyors, Filters, Presses, Process Lines, Radiators
• Paper- Calendar Mill Rolls, Caustic Lines, Scrubbers, Compressors, Liquor Tanks, Pulverizers, Vacuum Pumps
• Pharmaceutical- Exchangers, Loop Systems, Kathabars, Pumps, Reactors, Stills, Sterilizers
• Refinery - Compressors, Converters, Crackers, Exchangers, Piping, Pumps
• Rubber/Plastics - Banbury Mixers, Calendar & Mill Rolls, Extruders, Injection Molders, Molds, Temperature Control Units, Throat Coolers, Towers, Tubers
• Steel - Bearings, ConCast Units, Generators, Hearths, Spangle Units, Furnaces
• Textile - Air Washers,Compressors, Condensers, Exchangers, Extruders,Towers
Boilers
Condensers
Filters
Heat Exchangers
Kettles & Tanks
Pipelines
Pots
Reactors
Steam Jackets
Bath Rooms and Showers
Metal Processing and much more!
Applications
|
Automotive |
Bottling |
Chemicals |
Food |
|
- Closed Circuit Cooling - Dynamometers - Extruders - Molders - Radiators - Welders |
- CO2 Generators - Heaters - Exchangers - Rinse Tanks - Sterilizers and Washers |
- Dryers - Extruders - Kettles - Mixers - Reactors - Scrubbers - Vacuum Pumps |
- Condensers - Ice Machines - Kathabars - Refrigeration Equipment - Steam Tables |
|
Manufacturing |
Metals |
Mining |
Paper |
|
- Chillers - Compressors - Furnaces - Quenchers - Vacuum Pumps |
- Bearings - Conveyors - Fans - Hearth & Vacuum Furnaces - Shelters - Sprays |
- Bearings - Conveyors - Filters - Presses - Process Lines - Radiators |
- Calendar Rolls - Mill Rolls - Caustic Lines - Scrubbers - Compressors - Liquor Tanks - Pulverizers - Vacuum Pumps |
|
Pharmaceutical |
Refinery |
Rubber & Plastics |
Steel |
|
- Exchangers - Loop Systems - Kathabars - Pumps - Reactors - Stills - Sterilizers |
- Compressors - Converters - Crackers - Exchangers - Piping - Pumps |
- Banbury Mixers - Calendar & Mill Rolls - Extruders - Injection Molders - Molds - Temperature Control - Units - Throat Coolers - Towers and Tubers |
Bearings ConCast Units Generators Hearths Spangle Units Furnaces |
|
Textile |
Utilities |
Other Applications |
|
|
- Air Washers - Compressors - Condensers - Exchangers - Extruders and Towers |
- Boilers - Turbines - Transformers - Cooling Towers - Air Compressors - Hydrogen Coolers - Lube Oil Heat Exchangers |
- Ball Mills - Demisters - Evaporators - Locomotives - Absorption Units - Diesel Generators - Induction Furnaces |
Descaling Chemical manufacturers, Descaling Chemical suppliers, Descaling Chemicalproducers, Descaling Chemical exporters,
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | RXSOL-13-1048-025 |
| Product Type | Masonry Brick Cleaner |
Company Details:
RX MARINE INTERNATIONAL
105, A wing, BSEL, TECH PARK.
VASHI, NEW BOMBAY 400703 INDIA
Stock Point: Mumbai, Kandla, Kolkata, Chennai, Vizag, Fujairah, Muscat, Nairobi
| Phone | +91 22 65113333/5555/9999/27611360/27815540 |
| Fax | +91 22 2781 1318 ::: AOH: 0091 9322594669 |
| rxsolchemicals@gmail.com |
| Ingredient | CAS No. | % (w/w) |
| Hydrochloric acid | 7647-01-0 | 45-60 |
| Sulphuric acid | 7664-93-9 | 1-3 |
Classification according to CLP: Skin Corr. 1B; H314. Eye Dam. 1; H318. STOT SE 3; H335. Met. Corr. 1; H290.
Signal word: Danger.
Contains: Hydrochloric acid (15-20%).
Hazard statements: H314 Causes severe skin burns and eye damage. H318 Causes serious eye damage. H335 May cause respiratory irritation. H290 May be corrosive to metals.
Precautionary statements: P260 Do not breathe vapour/spray. P280 Wear eye protection and gloves. P305/351/338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 Immediately call a POISON CENTER/doctor. P501 Dispose of contents/container in accordance with local regulations. P102 Keep out of reach of children.
Other hazards: Reacts with a number of metals forming hydrogen gas, which may form explosive vapour/air mixtures. This product does not contain any PBT or vPvB substances.
Inhalation: Move injured person into fresh air and keep person calm under observation. If uncomfortable, seek hospital treatment and bring these instructions. Symptoms of lung oedema, including shortness of breath, may develop up to 24 hours after exposure. Immediately call an ambulance. Serious cases: If not breathing, give artificial respiration. Unconscious persons must be placed on their side, head low and kept warm. Call an ambulance and bring these instructions to the hospital.
Skin contact: Remove contaminated clothing and flush with plenty of water until pain disappears. If discomfort persists, transport to hospital and bring these instructions.
Eye contact: Immediately flush with plenty of water. Remove any contact lenses and open eyes wide apart. Call an ambulance and continue flushing during transportation to hospital. Bring these instructions.
Ingestion: Immediately rinse mouth and drink plenty of water or milk. Keep person under observation. Do not induce vomiting. If vomiting occurs, keep head low. Transport immediately to hospital and bring these instructions.
Medical attention/treatments: Treat symptomatically.
Extinguishing media: Use fire-extinguishing media appropriate for surrounding materials. Cool containers exposed to heat with water spray and remove container if no risk is involved.
Special hazards arising from the substance or mixture: During fire, gases hazardous to health may be formed.
Protective equipment for firefighters: Use air-supplied respirator during fire fighting.
Personal precautions: Look out. The product is corrosive. Avoid inhalation of vapours and contact with skin and eyes. Follow precautions for safe handling described in this safety data sheet.
Environmental precautions: Do not discharge into drains, water courses or onto the ground.
Methods for cleaning up: Absorb spillage with suitable absorbent material. Large quantities can be neutralised with lime. After cleaning, flush away remaining spillage with plenty of water.
Reference to other sections: For personal protection, see section 8.
Safe handling advice: Avoid inhalation of vapours and contact with skin and eyes. Immediately change drenched clothing. Observe good chemical hygiene practices.
Technical measures: Never pour water into acid/base. Dilute by slowly pouring the product into water while stirring.
Technical precautions: Mechanical ventilation may be required. Provide easy access to water supply and eye wash facilities. First-aid equipment, including eye wash bottle, must be available at the work site.
Storage conditions: Keep locked up. Store in tightly closed original container in a dry, cool and well-ventilated place. Protect from freezing and direct sunlight.
Specific end use: Universal cleaner for bricks and masonry.
Occupational exposure limits: Hydrogen chloride, gas and aerosol mists, CAS No. 7647-01-0: 1 ppm / 2 mg/m3 TWA; 5 ppm / 8 mg/m3 STEL 15 min. Sulphuric acid mist, CAS No. 7664-93-9: 0.05 mg/m3 TWA. Reference: EH40/2005.
Engineering measures: Provide adequate ventilation. Observe occupational exposure limits and minimise the risk of inhalation of vapours and spray mist. An eye wash bottle must be available at the work site.
Respiratory equipment: In case of inadequate ventilation, use suitable respirator.
Hand protection: Wear protective gloves. The most suitable glove must be chosen in consultation with the gloves supplier, who can inform about the breakthrough time of the glove material.
Eye protection: Wear goggles/face shield.
Skin protection: Wear apron or protective clothing in case of splashes. Wash contaminated clothing before reuse.
Hygiene measures: Wash hands after handling.
Environmental exposure controls: Not available.
| Appearance | Clear blue liquid |
| Odour | Acidic |
| Odour threshold | Not available |
| pH | 1-2 |
| Melting point / freezing point | Not relevant |
| Boiling point | 100°C |
| Flash point | Not relevant |
| Evaporation rate | Not available |
| Explosive limits | Not relevant |
| Vapour pressure | Not available |
| Vapour density | Not available |
| Relative density | 1.1 |
| Solubility | Completely soluble in water |
| Partition coefficient n-octanol/water | Not available |
| Auto-ignition temperature | Not relevant |
| Decomposition temperature | Not available |
| Viscosity | Not available |
| Explosive properties | Not relevant |
| Oxidising properties | Not available |
Reactivity: No data available.
Chemical stability: Stable under normal temperature conditions.
Possibility of hazardous reactions: No data available.
Conditions to avoid: Do not add water directly to the product. It may cause a violent reaction.
Incompatible materials: Strong bases. Strong oxidizing and reducing substances.
Hazardous decomposition products: When heated, toxic vapours are formed.
Acute toxicity, oral: Based on available data, the classification criteria are not met.
Acute toxicity, dermal: Based on available data, the classification criteria are not met.
Acute toxicity, inhalation: Based on available data, the classification criteria are not met.
Skin corrosion/irritation: Causes severe skin burns and eye damage.
Serious eye damage/irritation: Causes serious eye damage.
Respiratory or skin sensitisation: Based on available data, the classification criteria are not met.
Germ cell mutagenicity: Based on available data, the classification criteria are not met.
Carcinogenicity: Based on available data, the classification criteria are not met.
Reproductive toxicity: Based on available data, the classification criteria are not met.
STOT - single exposure: May cause respiratory irritation.
STOT - repeated exposure: Based on available data, the classification criteria are not met.
Aspiration hazard: Based on available data, the classification criteria are not met.
Inhalation: Spray mists are corrosive. Vapours irritate the respiratory system and may cause coughing and difficulties in breathing.
Skin contact: Causes burns.
Eye contact: Causes burns. Risk of serious damage to eyes. Immediate first aid is necessary.
Ingestion: Corrosive. Immediate first aid is necessary. May cause chemical burns in mouth and throat.
Ecotoxicity: The product may affect the acidity, pH factor, in water with risk of harmful effects to aquatic organisms.
Persistence and degradability: The product solely consists of inorganic compounds which are not biodegradable.
Bioaccumulative potential: No data available on bioaccumulation.
Mobility in soil: No data available.
PBT/vPvB: This product does not contain any PBT or vPvB substances.
Other adverse effects: None known.
Dispose of waste and residues in accordance with local authority requirements. Waste is classified as hazardous waste.
Waste from residues: EWC-code 20 01 29.
| UN number | 3264 |
| Proper shipping name | CORROSIVE LIQUID, ACIDIC, INORGANIC, N.O.S. (Hydrochloric acid, Sulphuric acid) |
| Transport hazard class | 8 |
| Packing group | II |
| Marine pollutant | No |
| Environmentally hazardous substance | No |
| Special precautions for user | None known |
| Transport in bulk | Not relevant |
Special provisions: As a general rule, persons under 18 years of age are not allowed to work with this product. Users must be carefully instructed in the proper work procedure, the dangerous properties of the product and the necessary safety instructions.
Additional label/packaging statement: Less than 5% non-ionic surfactants.
National regulation: Regulation (EC) No 1907/2006 concerning REACH, with amendments. Regulation (EC) No 1272/2008 on classification, labelling and packaging of substances and mixtures, with amendments. The Control of Substances Hazardous to Health Regulations 2002, with amendments. EH40/2005 Workplace exposure limits 2005, with amendments. Regulation (EC) No 648/2004 on detergents. The Management of Health and Safety at Work Regulations 1999, with amendments. The List of Wastes (England) (Amendment) Regulations 2005.
Chemical safety assessment: No chemical safety assessment has been carried out.
Supersedes date: 2019-10-23. Last revised date: 2020-07-16. Source SDS-ID: GB-EN/3.0.
Abbreviations and acronyms used in the safety data sheet: PBT = Persistent, Bioaccumulative and Toxic. vPvB = very Persistent and very Bioaccumulative.
Classification according to Regulation (EC) No. 1272/2008: Calculation method.
Wording of H-statements: H290 May be corrosive to metals. H314 Causes severe skin burns and eye damage. H318 Causes serious eye damage. H335 May cause respiratory irritation.
The information on this data sheet represents our current data and is reliable provided that the product is used under the prescribed conditions and in accordance with the application specified on the packaging and/or in the technical guidance literature. Any other use of the product which involves using the product in combination with any other product or any other process is the responsibility of the user.
Availability
Descaling chemicals, scale remover, Descalex powder, Safe Acid manufacturer, exporter and supplier in India, Oman, Middle East. We are also popular name as a descaling chemicals supplier in Fujairah, Muscat, Mumbai, Gandhidham, Visakhapatnam, Chennai, Kolkata Howrah. And we have daily day by day descaling supply services in Dubai, Sharjah, Ajman, Abudhabi, umm al quwain in UAE, and Barka, Salalah, Sohar, Muscat in Oman, And Surat Hazira, Howrah, Paradip, Haldia, Ennore, Chennai, Visakhapatnam, Gangavaram, Jamnagar Sikka, Mundra, Kandla Gujrat, Sudan, Yemen, Africa, Nairobi KENYA