RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,061 products across 71 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Lab Chemical

Nitric Acid 3.0 Normal Solution

Lab Reagent
Part number
RXSOL-60-6255-500
Category
Lab Chemical
Brand
RXSOL
Nitric Acid 3.0 Normal Solution

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name Nitric Acid 3.0 Normal Solution
Product Type RXSOL-60-6255-500

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA 

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
SARA 313 Component  CAS Number Percent Comp. Dimension
 
Exposure
 Limits
 
Nitric Acid CAS# 7697-37-2

 18 - 20%

V/V OSHA TWA 2ppm(5mg/mƒ),STEL 4 ppm
Water, Deionized ASTM Type II CAS# 7732-18-5 Balance V/V None Established

Causes severe irritation and burns. May Be harmful if swallowed. Avoid breathing vapor or dust. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling. Keep container closed.

Emergency Overview: Poison! Danger! Oxidizer. Contact With Other Material May Cause Fire.Corrosive. Liquid And Mist Cause Severe Burns To All Body Tissue. May Be Fatal If Swallowed. Harmful If Inhaled. Inhalation May Cause Lung And Tooth Damage.

Inhalation: Corrosive! Inhalation of Vapors can Cause Breathing Difficulties and Lead to Pneumonia and
Pulmonary Edema, Which may be Fatal. Other Symptoms may Include Coughing, Choking, and Irritation of the Nose, Throat, and Respiratory Tract.

Ingestion: Corrosive! Swallowing Nitric Acid can Cause Immediate Pain and Burns of the Mouth, Throat,
Esophagus and Gastrointestinal Tract.

Skin: Corrosive! Can Cause Redness, Pain, and Severe Skin Burns. Concentrated Solutions Cause Deep Ulcers and Stain Skin Yellow or Yellow-Brown Color.

Eye Contact: Corrosive! Vapors are Irritating and may Cause Damage to the Eyes. Contact may Cause Severe Burns and Permanent Eye Damage.

Chronic Exposure: Persons with Pre-Existing Skin Disorders, Eye Disease, or Cardiopulmonary
Diseases may be more Susceptible to the Effects of this Substance.

Aggravated by Exposure: More Susceptible to the Effects of this Substance.

Causes severe irritation and burns. May Be harmful if swallowed. Avoid breathing vapor or dust. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling. Keep container closed.

SKIN:

In case of contact, immediately flush skin with water for at least 15 minutes while removing contaminated clothing and shoes. Thoroughly clean clothing and shoes before reuse
EYES: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally.Seek Medical Aid.
INHALATION: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen
INGESTION: Give several glasses of milk or water. Vomiting may occur spontaneously, but DO NOT INDUCE! Never give anything by mouth to an unconscious person.

Fire Extinguisher Type:

Water spray, Carbon dioxide, dry chemical, powder, foam.
Fire / Explosion Hazards: May react explosively with combutible organic or readily oxidizing materials.
Fire Fighting Procedure: Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and clothing.

Absorb with inert material and recover for proper disposal.Neutralize with weak base.

Ventilate area or Leak or Spill. Remove all Sources of Ignition.Wear Appropriate Personal
Protective Equipment as Specified in Section 8. Isolate HazardArea. Keep Unnecessary and Unprotected Personnel from Entering. Contain and Recover Liquid when Possible. Neutralize with Alkaline Material (Soda Ash. Lime), then Absorb with an Inert Material (e.g., Vermiculite, Dry Sand, Earth), and Place in a Chemical Waste Container. Do Not Use Combustible Materials, such as Saw Dust. Do Not Flush to Sewer! If a Leak or Spill has not Ignited, Use Water Spray to Disperse Vapors, to Protect Personnel Attempting to Stop Leak, and to Flush Spills Away from Exposures.US Regulations (CERCLA) Require Reporting Spills and Releases
to Soil, Water and Air in Excess of Reportable Quantities

Store in a cool, dry, well-ventilated place away from incompatible materials. Wash thoroughly after handling.

Respiratory Protection

NIOSH/MSHA-approved respirator
Ventilation  Local
OTHER Mechanical
Protective Gloves NIOSH Approved Gloves
EYE PROTECTION Splash Goggles
Other Protective Equipment Wear appropriate clothing to prevent skin exposure
BOILING POINT information not available
VAPOR PRESSURE  not available
MELTING POINT information not available
VAPOR DENSITY  not available
EVAPORATION RATE information not available
 
Appearance /Odors Clearless liquid,odorless
Flash Point

Not applicable

Specific Gravity information not available
Percent Volatile by >90
Evaporation Standard  
Auto Ignition Temp

Not applicable
 

Lower Flamm. Limit in Air Not applicable
 
Upper Flamm. Limit in Air  Not applicable
 
Solubility in Water Soluble

STABILITY

Stable

CONDITIONS TO AVOID

Extreme heat

MATERIALS TO AVOID

Oxidizers, bases, metal powders,carbides, organic materials

HAZARDOUS DECOMPOSITION PRODUCTS

Toxic Nitrogen Oxides

HAZARDOUS POLYMERIZATION

will not occur
 
Conditions to Avoid  None known

Hydrogen Chloride - IARC Category 3, NTP Carcinogen - Known: No

Environmental Fate: No information found

Environmental Toxicity: No information found

Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste facility. Although not a listed RCRA hazardous waste, this material may exhibit one or more characteristics of a hazardous waste and require appropriate analysis to determine specific disposal requirements. Processing, use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements

DOT Classification: UN2031, Nitric Acid Solution, 8, PG II

DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations.

Chemical Inventory Status –
Part 1:Ingrdient
Nitric Acid (7697-37-2)
TSCA Yes
EC Yes
Japan YES
Australia Yes

Chemical Inventory Status –
Part 2:Ingredient
Nitric Acid (7697-37-2)
Korea Yes
DSL Yes
NDSL No
Phil. Yes

Federal, State & International Regulations –
Part 1: Ingredient.
Nitric Acid (7697-37-2)
RQ 1000
TPQ 1000
List YES
Chemical Catg No

Federal, State &
International Regulations –
Part 2:Ingredient
Nitric Acid (7697-37-2)
CERCLA 1000
261.33 No
8(d) No
Chemical Weapons Convention: No
TSCA 12 (b):No
CDTA:No MIXTURE/LIQUID
SARA 311/312: Acute:YES
Chronic: YES
Fire: No
Pressure: No
Reactivity: YES
Australian Hazchem Code: 2PE
Poison Schedule:S6

Conditions aggravated/Target organs: Persons with preexisting skin, eye, or respiratory disorders may be more susceptible. Acute: Corrosive. Irritation and burns to skin, eyes, lungs, mucous membranes, and GI tract. Coughing, Choking. Chronic: Errosion                                                     

                                             Flammability
 

Health                                                                                                     Reactivity 

Revisions

  NFPA
7/30/2010 0.1 updated msds to 16 section from 10 section msds. STN
   0

The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Nitric Acid 3.0 Normal Solution manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Nitric Acid 3.0 Normal Solution at a competitive price from us. We have ready stock of Nitric Acid 3.0 Normal Solution in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches