RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,116 products across 118 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Coolant Glycol Antifreeze

RADIATOR Coolant

Inhibitor concentrate chemical which is added to the cooling water of internal combustion engines in cases in which the coolant does not need to be protected from freezing. It efforts excellent protection against cavitation and corrosion to all metal
Part number
RXSOL-40-4004-010
Generic name
Coolant for Radiator
Brand
RXSOL
RADIATOR Coolant

Overview

It is a blend of organic compound along with 3 to 15% benzotriazole is especially useful in preventing cavitation corrosion in high speed coolant pumps having aluminum housing and impellers. This could aid service life.
 

DIESEL ENGINE WATER TREATMENT SUITABLE FOR ALUMINIUM, ALLOYS AND YELLOW METALS

RXSOL-40-4004 is an inhibitor concentrate/chemical which is added to the cooling water of internal combustion engines in cases in which the coolant does not need to be protected from freezing. It efforts excellent protection against cavitation and corrosion to all metals and alloys that are used in cooling systems.It is especially appropiate for the use in heavy-duty engines such as those used in trucks,  ships and lokomotives.


• High performance corrosion inhibitor
• Being a nitrite free product it is compatible also with zinc - coated piping
• Easy control test with refractometer.

Applications

APPLICATION :

At concentration of 10% by volume,RXSOL-40-4004 affords excellent protection against cavitation and corrosion to all metal and alloys which are used in cooling system, such as aluminium, ferrous and yellow metals.

PHYSICAL DATA
Appearance       : Clear liquid
Density               : 1.096 g/cm3
Product pH neat: 9.5
Corrosive action: None

Industrial areas

Radiator Maintenance chemicals and Radiator Coolant Manufacturer and Supplier :

Radiator Coolant 20% Conc. ::: Part No.- RXSOL-40-4045-025
Suitable to add to the cooling water of internal combustion engines for excellent protection against cavitation and corrosion to all metals and alloys that are used in cooling systems.It is especially appropiate for the use in heavy-duty engines such as those used in trucks,  ships and lokomotives. 

Coolant Green RXSOL G 93-94 ::: inhibitor concentrate/chemical which is added to the cooling water of internal combustion engines in cases in which the coolant does not need to be protected from freezing. It efforts excellent protection against cavitation and corrosion to all metals Part No.- RXSOL-40-4021-025 


Coolant 25 Ltrs ::: Useful in preventing cavitation corrosion in high speed coolant pumps having aluminum housing and impellers. This could aid service life. Part No.- RXSOL-40-4004-025


Coolant Premix Redcool ::: premix coolant which reduces cavitation in areas such as the water pump and surface cavitation in hot spots of the cylinder head. The minimisation of cavitation erosion and pitting of heat rejecting aluminium surfaces (eg. behind exhaust ports)  Part No.- RXSOL-40-4043-025
Radiator Condensor Scale Controler::: 
Condensor Dispersant Scale Controler (For Radiators, DG - sets, Closed Cooling System) , Specially formulated for SCALE CONTROL . The stable oxide film that is formed by RXSOL-40-4007-020 prevents corrosion caused by electrolytic action between dissimilar metals used in the system. RXSOL-40-4007-020 has been field tested and found to have no detrimental effects on non metallic substances such as seals, glands, packing, hoses, gaskets etc., normally used in the systems. Part No. RXSOL-40-4007-020


Radiator Cleaner ::: This is specially formulated for use as radiator cleaner. Radiator cleaner removes the dirt, grease, scale, grime & solder from the engine cooling system. Radiator cleaner is a powerful cleaning agent not only for the automobile engine but can be used for the steam tube and boiler tube etc. Part No.- RXSOL-16-2697-025

Engine Water Treatment DEWT ::: Multi-functional corrosion inhibitor for protecting recirculating cooling and heating water systems. RXSOL LIQUID EWT treatment is an excellent treatment for diesel engine primary and secondary cooling water. It is also ideally suited for use in chilled water systems because it forms a clear, non-staining solution, which protects the system from corrosion and hard water scale.  Part No.- RXSOL-40-4010-025
Engine Parts Washing Solvent ( RXSOL - PWS ) :::  This product provides an economical and effective method for cleaning metal parts while being gentle on the hands.  Grease, oil, dirt, sludge, grime, ink, light carbon and similar soils are dissolved with minimal soaking and brushing.  Machine shops, garages, factories, industrial repair shops and automobile make-ready facilities will find this product to be an ideal compound for use in their recirculating parts washer units. Part No. RXSOL-10-1727-025


Carbon Remover ::: Concentrated RXSOL-16-1003-025 is most effective product in its category due to its quick and complete action. can be applied for cleaning of highly soiled components. blocks, gear boxes, pistons, rings, valves, atomizers, pipes, burners, coolers, cylinder etc.. Part No.- RXSOL-16-1003-025


Hand Cleaner Paste, Waterless ::: It is a milky white creamy gel containing natural ingredients, moisturisers, surfactants, and powerful dispersing agents. This is a batter substitute to petroleum products & caustic based detergetns which drain the body oil. ONLY 2 TO 5 grams SUFFICIENT tRXSOL-16-1001-001

Email us to get best discounted price for Radiator coolant and Cleaner in India - UAE Middle East - Oman : mail@rxmarine.com

Dosage and directions

The coolant should be prepared with water that is clean but not too hard. The following types of water are unsuitable: sea water,mixture of sea water and fresh water, salt water and industrial waste water. The analytical values of the water should be within the

following limits:
Water hardness   : 0 -    100 ppm
Chloride contents: max 100 ppm
Sulphate contents: max 100 ppm


The water must be treated by suitable means if it does not fulfill these requirements, i.e. by adding softened, or distilled or deionized water. Excessive sulphate or chloride contents can also be reduced by adding distilled or deionized water.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name RXSOL-40-4004-010
Product Type COOLANT

 Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

STOCK POINT : Mumbai, Kandla, Kolkata, Chennai, Vizag, Fujairah, Muscat, Nairobi

Phone +91 22 65113333 / 5555 / 9999 / 27611360
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com

Chemical Name

Concentration

CAS Number

EC Number

R Phrases*

Symbols

Glycol

40-50%

107-21-1

50

5

0

3 to 15% benzotriazole is especially useful in preventing cavitation corrosion in high speed coolant pumps having aluminum housing and impellers.
This could aid service life.
*See Section 16

 Odour

Characteristic odour

 Appearance

Liquid, Slight yellow, soluble in water

 Contact with eyes

Causes irritation

 Contact with skin

In cases of severe exposure, irritation may develop

 Inhalation

None

 Ingestion

None

Contact with skin

Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash with soap and water  Seek medical advice if necessary.

Contact with eyes

If substance has got into eyes, immediately washout  with plenty of water for at least 15 minutes Obtain immediate medical attention.

Ingestion

Never give anything by mouth to anunconscious person Give plenty of water to drink Obtain immediate medical attention.

Inhalation

Remove patient to fresh air  Keep warm and at rest, inahalfup right position. Loos enclothing Seek medical attention if irritation persists.

General

In case of accident or if you feel unwell, seek medical advice immediately(show the label where possible)(S45).

 -*See Section16
 

-  Smoke from fires is irritating
-  Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions

Personal Precautions

Wear protective clothing as persection 8

Environmental Precautions

No special precautions are required for this produc

Immediate Actions

Shut off source of leak if safe to do so

Clean Up Actions

Absorb spillagein inert material and shovel up Flush spill area with copious amounts of water

Special Precautions

Wear protective clothing as persection 8

Handling

The usual precautions for handling chemicals should be observed Eye wash bottles should be available
See Section 8

Storage

Keep only in the original container in a cool, well ventilated place(S3/9/49) Protect from frost

Exposure Limits

There are no recommended or established controls for this product

Exposure controls

No special ventilation is required unless the product is used in as pray form

Occupational exposure controls

Wear suitable protective clothing, including eye/face protection and gloves(plastic or rubber are recommended) No respiratory protection is required unless subject to contact with substance mist

Odour

Characteristic odour

Appearance

Liquid, Slight yellow, soluble in water

pH

7.5-8.5at 5-10%concentration

Boilingpoint

>230°F

Vapour pressure

not known

Freezing point

Anti Freezing Liquid

Completely soluble in water

Specific gravity(water=1)

1.07

-This article is considered stable under normal conditions
-See Section 5

Toxicological information

No experimental data available

Inhalation

None

Contact with skin

Reddening Skin

Contact with eyes

Reddening Eyes

Ingestion

None

Carcinogenicity

No evidence of carcinogenic effects

Ecotoxicity
 

This product does not contain ingredients which are classified in the EUas dangerous for the environment. Mobility  Completely soluble in water

Persistence and Biodegradability

Its mainingredients will either dissolve rapidly and dissociate in water or are readily /inherently biodegradable.

Bioaccumulation Potential

Bioaccumulation of the components in this product is in significant.

Other Adverse Effects

No environmental problems are expected when the product is used/ handled correctly.

Mobility

Completely soluble in water

Classification

This material and/or its container must be disposed of as hazardous waste EUWaste class 

Disposal considerations

Disposal should be in accordance with local, state or national legislation

- Not classified as hazardous for transport

Risk Phrases

Irritating to eyes(R36)

Safety Phrases

In case of contact with eyes, rinse immediately with plenty of water and seek medic aladvice(S26) Wear suitable gloves and eye/face protection(S37/39)

Text of R and S phrase codes used in this safety data sheet:- R34: Causes burns;  R36: Irritating to eyes;  R37: Irritating to respiratory system;  R41: Risk of serious damage to eyes.The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold assuitable for other applications-usage in such may cause risks not mentioned in this sheet. Donot use for other application(s) with out seeking advice from manufacturer  This Safety Data Sheet is provided in compliance with The Dangerous Substances Directive(67/548/EEC)  This Safety Data Sheet is provided in compliance with The Dangerous Preparations Directive(88/379/EEC) This Safety Data Sheet is provided in compliance with The Safety Data Sheets Directive(2001/58EC)

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Technical bulletin

Open technical bulletin

It is a blend of organic compound along with 3 to 15% benzotriazole is especially useful in preventing cavitation corrosion in high speed coolant pumps having aluminum housing and impellers. This could aid service life.
 

DIESEL ENGINE WATER TREATMENT SUITABLE FOR ALUMINIUM, ALLOYS AND YELLOW METALS

RXSOL-40-4004 is an inhibitor concentrate/chemical which is added to the cooling water of internal combustion engines in cases in which the coolant does not need to be protected from freezing. It efforts excellent protection against cavitation and corrosion to all metals and alloys that are used in cooling systems.It is especially appropiate for the use in heavy-duty engines such as those used in trucks,  ships and lokomotives.


• High performance corrosion inhibitor
• Being a nitrite free product it is compatible also with zinc - coated piping
• Easy control test with refractometer.

APPLICATION :

At concentration of 10% by volume,RXSOL-40-4004 affords excellent protection against cavitation and corrosion to all metal and alloys which are used in cooling system, such as aluminium, ferrous and yellow metals.

PHYSICAL DATA
Appearance       : Clear liquid
Density               : 1.096 g/cm3
Product pH neat: 9.5
Corrosive action: None

DOSE

The coolant should be prepared with water that is clean but not too hard. The following types of water are unsuitable: sea water,mixture of sea water and fresh water, salt water and industrial waste water. The analytical values of the water should be within the

following limits:
Water hardness   : 0 -    100 ppm
Chloride contents: max 100 ppm
Sulphate contents: max 100 ppm


The water must be treated by suitable means if it does not fulfill these requirements, i.e. by adding softened, or distilled or deionized water. Excessive sulphate or chloride contents can also be reduced by adding distilled or deionized water.

Availability

COOLANT Manufcaturer and supplier in INDIA - UAE MIDDLE EAST GULF, OMAN, Nairobi Kenya, Sudan, Yemen. RXSOL COOLANT RXSOL-40-4004-025 exporter and supplier in Mumbai, Surat, Gandhidham, Kolkata, Chennai, Vizag Visakhapatnam, Paradip, Fujairah, Ajman, Abudhabi, Sharjah, Dubai, RUWI, Barka, Muscat, Sohar, Oman, Canada

Our stock points and branches