Rifle Bore Cleaner RXSOL
- Part number
- RXSOL-68-6826-025
- Category
- Metal Treatment
- Brand
- RXSOL
Overview
RXSOL Rifle Bore Cleaner is a highly penetrating, mobile liquid and is intended for field application to satisfy the complete need of cleaning of military weapons. Facilitates the effective removal of copper, firing residues, gums and other contaminants from weapon components.This product is for use in cleaning caliber military weapons, operating in the temperature range of -45° C to + 43° C (-49° F to +110° F).
RXSOL Rifle Bore Cleaner is not intended for storage and should be removed after use. An appropriate lubricant should be used for preservative and lubrication in accordance with an appropriate weapons manual or lubrication order.
Technical specifications
| Appearance | : Amber liquid |
| Odor | : Mild |
| Odor Threshold | : Not available |
|
pH |
: Not Applicable |
| Flash Point | : 65°C |
| Boiling Point | : >150° C |
| Density | : 0.861 g/cm3 |
| Auto Ignition Temperature | : 254° C |
| Refractive Index | : 1.455 |
| Water Solubility | : Negligible |
Dosage and directions
Saturate patch with bore solvent and push through bore from breech and out muzzle. Repeat with clean saturated patch. Follow with dry patch. Repeat wet-dry patch process until bore is clean.
For stubborn deposits, leave on for up to 60 minutes before removing. Never plug or leave patch in bore.Run a dry patch through bore before firing. Safe to use on metals. Will not cause rust, oxidation, staining or galvanic corrosion. May be harmful to some paints, varnishes, and plastics. Keep product off these types of surface unless a previous patch test has shown no effect. For firearms use only.
Characteristics and notes
Benefit :
- Safe to use on metals.
- Will not cause rust, oxidation, staining, or galvanic corrosion.
- Easy to use
Note : Due to the solvent systems employed in Rifle Bore Cleaner type formulations, field users should avoid using RBC in conditions of limited ventilation, that is, closed rooms, sealed vehicles, etc.
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | Rifle Bore Cleaner RXSOL |
| Part Number | RXSOL-68-6826-025 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Kolkata, Chennai, Vizag, Fujairah, Muscat
| Phone | +91 22 27612100 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com | |
| Website | www.rxmarine.com |
| Name of Substance | Cas Number | Weight % |
| AROMATIC HYDROCARBON | 64742-95-6 | 20-25 |
| HYDROCARBON SOLVENT | 64742-94-5 | 20-25 |
| METHYL AMYL ALCOHOL | 108-11-2 | 5-10 |
| ETHYLENE GLYCOL MONOBUTYL ETHER | 111-76-2 | 6-10 |
| PETROLEUM HYDROCARBON | 64742-52-5 | 5-10 |
| OLEIC ACID | 112-80-1 | 5-10 |
| AMMONIUM HYDROXIDE | 1336-21-6 | 1-2 |
| Signal Word | Warning |
| Hazard Statements |
H226: Flammable Liquid And Vapour.
H332: Harmful If Inhaled.
H319: Causes Serious Eye Irritation
H315: Causes Skin Irritation.
H373: May Cause Damage To Organs Through Prolonged Or Repeated Exposure.
H304: May Be Fatal If Swallowed And Enters Airways
H226: Flammable Liquid And Vapour.
H332: Harmful If Inhaled.
H319: Causes Serious Eye Irritation
H315: Causes Skin Irritation.
H373: May Cause Damage To Organs Through Prolonged Or Repeated Exposure.
H304: May Be Fatal If Swallowed And Enters Airway
|
| Precautionary statements - prevention |
P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233: Keep container tightly closed.
P240: Ground and bond container and receiving equipment.
P241: Use explosion-proof equipment.
P242: Use only non-sparking tools.
P243: Take precautionary measures against static discharge.
P261: Avoid breathing vapours.
P271: Use only outdoors or in a well-ventilated area.
P280: Wear protective gloves/protective clothing/eye protection/face protection.
P264: Wash face, hands and any exposed skin thoroughly after handling.
P260: Do not breathe dust/fume/gas/mist/vapours/sprayP210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233: Keep container tightly closed.
P240: Ground and bond container and receiving equipment.
P241: Use explosion-proof equipment.
P242: Use only non-sparking tools.
P243: Take precautionary measures against static discharge.
P261: Avoid breathing vapours.
P271: Use only outdoors or in a well-ventilated area.
P280: Wear protective gloves/protective clothing/eye protection/face protection.
P264: Wash face, hands and any exposed skin thoroughly after handling.
P260: Do not breathe dust/fume/gas/mist/vapours/spray
|
| Precautionary statements - response |
P302+P352: IF ON SKIN (or hair): Wash with plenty of water.
P332 + P313: If skin irritation occurs: Get medical advice/attention.
P362 + P364: Take off contaminated clothing and wash it before reuse.
P304 + P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses,
if present and easy to do. Continue rinsing.
P337 + P313: If eye irritation persists: Get medical advice/attention.
P312: Call a POISON CENTER or doctor if you feel unwell.
P301 + P310: IF SWALLOWED: Immediately call a POISON CENTER or doctor.
P331: Do not induce vomiting.
P330: Rinse mouth.
P370 + P378: In case of fire: Use dry chemical, CO2, or Halon for extinction.P302+P352: IF ON SKIN (or hair): Wash with plenty of water.
P332 + P313: If skin irritation occurs: Get medical advice/attention.
P362 + P364: Take off contaminated clothing and wash it before reuse.
P304 + P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses,
if present and easy to do. Continue rinsing.
P337 + P313: If eye irritation persists: Get medical advice/attention.
P312: Call a POISON CENTER or doctor if you feel unwell.
P301 + P310: IF SWALLOWED: Immediately call a POISON CENTER or doctor.
P331: Do not induce vomiting.
P330: Rinse mouth.
P370 + P378: In case of fire: Use dry chemical, CO2, or Halon for extinction.
|
| Precautionary Statements – Storage |
P403 + P233: Store in a well-ventilated place. Keep container tightly closed. Keep cool.
P405: Store locked up.P403 + P233: Store in a well-ventilated place. Keep container tightly closed. Keep cool.
P405: Store locked up.
|
| Precautionary Statements – Disposal |
P501: Dispose of contents/container to an approved waste disposal plant.
|
| Skin Contact |
IF ON SKIN: Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. Wash contaminated clothing before reuse. Seek medical attention if irritation occurs
|
| Eye Contact |
IF IN EYES: Rinse cautiously with water for several minutes. Check for and remove any contact lenses. Immediately flush eyes thoroughly with plenty of water for at least 15 minutes, lifting lower and upper eyelids. Get medical attention immediately.
|
| Inhalation: |
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a poison control center or physician.
|
| Ingestion |
IF SWALLOWED: Clean mouth with water. Do not induce vomiting or give anything by mouth to an unconscious person. Call a physician or poison control center immediately
|
| Most important symptoms/effects |
Direct contact with eyes causes serious irritation. Substance causes skin irritation. Harmful if inhaled. May cause irritation to the mucous membranes and upper respiratory tract. Choking, coughing and headache may occur. May cause irritation to the digestive tract.
|
| Notes to Physician | Treat symptomatically |
| Suitable extinguishing media |
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.Dry Chemical CO2, Halon.
|
| Unsuitable Extinguishing Media | Do not use water |
| Specific Hazards Arising from the Chemical | IFlammable liquid. In a fire or if heated, a pressure increase will occur and the container may burst. Runoff to sewer may create fire or explosion hazard. |
| Protective Equipment and Precautions for Firefighters |
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
|
|
Personal Precautions, Protective Equipment and Emergency Procedures Personal Precautions
|
Use personal protective equipment. Ensure adequate ventilation. Remove all sources of ignition. Take precautionary measures against static discharges. |
| Methods for Containment |
For small spills, absorb on poly-pads or other suitable non-reactive absorbent material. Prevent further leakage or spillage if safe to do so.
|
| Methods and materials for containment and cleaning |
Eliminate all sources of ignition. Use non-sparking hand tools and explosion-proof electrical equipment. Sweep up and shovel into suitable containers for disposal. Discard any product, residue, disposable container or liner in full compliance with federal, state, and local regulations.
|
| Advice on Safe Handling |
Handle in accordance with good industrial hygiene and safety practice. Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Use personal protection recommended in Section 8. Use only in wellventilated areas. Do not breathe vapors or spray mist. Keep away from heat, sparks, flame and other sources of ignition. All equipment used when handling the product
must be grounded.
|
|
Conditions for Safe Storage, Including any Incompatibilities
Storage Conditions
|
Keep containers tightly closed in a dry, cool and well-ventilated place. Store locked up. Incompatible Materials Strong oxidizing agents.
|
| Engineering Control | Use only with adequate ventilation. If user operations generate dust, fumes, gas, vapor or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. |
| Personal Protection |
Eye/face Protection : Avoid contact with eyes. Wear safety eyewear Skin and body protection : Wear suitable protective clothing. Use impervious gloves Respiratory Protection : Ensure adequate ventilation, especially in confined areas |
| Hygiene Measures | Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and the using the bathroom and at the end of the working periods. |
Gloves Suit
| Form | Liquid |
| Colour | Clear |
| Odour | Ammonia scent |
| Odor Threshold | Not determined |
| pH | 9.8 |
| Melting Point | Not determined |
| Boiling Point | 177 Deg F |
| Flash Point | 116 (tcp) |
| Evaporation Rate | (H2O = 1) >1 |
| Flammability (solid, gas) | n/a-liquid |
| Vapour pressure | 20@68f |
| Vapour Density | Not determined |
| Secific Gravity | 0.911 |
| Decomposition Temperature | No information available |
| Partition coefficient | No data available |
| Autoignition Temperature | Not determined |
| Solubility in Water | Soluble in water |
| Viscosity | No information available |
| Explosive Properties Oxidizing | Heated drums can explode |
| Recativity | Not reactive under normal conditions |
| Chemical Stability | Stable under recommended storage conditions |
| Possibility of hazardous reactions | None under normal processing. |
| Conditions to avoid | Keep out of reach of children. Avoid all possible sources of ignition (spark or flame). |
| Incompatible materials | Strong oxidizers, sparks or open flame |
| Hazardous Decomposition Products | Will not occur. In a fire: Carbon Monoxide, Carbon Dioxide and Hydrocarbons |
| Hazardous Polymerization | Hazardous polymerization does not occur. |
| Eye Contact | Causes severe eye irritation. |
| Inhalation | Harmful if inhaled. |
| Skin Contact | May cause skin irritation. |
| Ingestion | May be fatal if swallowed and enters |
| Symptoms | Please see section 4 of this SDS for symptoms |
| Carcinogenicity | This product does not contain any carcinogens or potential carcinogens as listed by OSHA, IARC or NTP |
| Ecotoxicity | Material expected to be toxic to aquatic organisms. May cause long-term adverse effects in the aq |
| Persistence and Degradability | Not Available |
| Bioaccumulationn | Not expected to bioaccumulate significantly. |
| Other adverse effects | Not determined |
| Waste treatment Method |
Disposal of Wastes - Disposal should be in accordance with applicable regional, national and local laws and regulations. Contaminated Packaging - Disposal should be in accordance with applicable regional, national and local laws and regulations. |
Note - Please see current shipping paper for most up to date shipping information, including exemptions and special circumstances
DOT - UN1993, FLAMMABLE LIQUID, N.O.S., (PETROLEUM NAPHTHA, METHYL AMYL ALCOHOL) 3, PGIII
IATA - Not available.
IMDG - Not available.
TDG - Not regulated
| International Inventories | Not determined |
| US Federal Regulations | SARA 313 Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA). This product contains a chemical which is subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372. |
| Chemical Name | CAS No | Weight-% |
| AMMONIUM HYDROXIDE | 1336-21-6 | 1-2 |
| ETHYLENE GLYCOL MONOBUTYL ETHER | 111-76-2 | 6-10 |
U.S. State Right-to-Know Regulations :
| Chemical Name | New Jersey | Massachusetts | Pennsylvania |
| Methyl Amyl Alcohol | X | X | X |
| Aromatic Hydrocarbon | X | X | X |
| Ethylene Glycol Monobutyl Ether | 90-100% | 90-100% | 90-100% |
| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if RX Marine International has been advised of the possibility of such damages. DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable. |
Availability
Rifle Bore Cleaner RXSOL manufacturer and supplier in Fujairah, Muscat, Nairobi, Mumbai, Gandhidham, Visakhapatnam, Kolkata, Chennai, Dubai, Ajman, Jerf, Abudhabi, Sharjah, Barka Sohar, Oman, Gulf Middel East Canada