RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,064 products across 81 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Drilling Fluids & Mud Oil Field chemicals

Surfactant Non Ionic fracturing RXSOL112

Surfactant RX 112 (Non Ionic fracturing surfactant) is a non-ionic, non-flammable surfactant for use in acidizing and fracturing treatments. It is designed to improve recovery of the injected stimulation fluids and enhance ultimate recovery of hydroc
Part number
RXSOL-81-2224-210
Brand
RXSOL
RXSOL

Overview

Surfactant RX 112 (Non Ionic fracturing surfactant) is a non-ionic, non-flammable surfactant for use in acidizing and fracturing treatments. It is designed to improve recovery of the injected stimulation fluids and enhance ultimate recovery of hydrocarbons.

Technical specifications

Physical state   : Liquid
Appearance   : Aqueous Solution
Odor    : Alcohol
Color    : Clear Yellow
Odor threshold   : Not applicable
pH    : 9-11
Freezing point  : 5 °C / 41 °F
Boiling point   : ~ 100 °C / 212 °F
Flash Point  :  > 93.3 °C / > 199.4 °F
Specific gravity  : 0.99 - 1.05 g/cm3

Applications

Surfactant RX 112 (Non Ionic fracturing surfactant) is compatible with all known fracturing fluid additives and has been successfully used for the past few years. Surfactant RX 112 (Non Ionic fracturing surfactant) is also pumped with acid spearheads to lower the breakdown pressures and minimize the possibilities of forming acid/oil emulsions where a separate non-emulsifier is not used.

Dosage and directions

Compatibility:
Surfactant RX 112 (Non - Ionic fracturing surfactant) is compatible with most acidizing and fracturing treatment additives and friction reducers. However, a compatibility test is advised before use.

Typical Dosage:
Typically used at 1 to 2 GPT with stimulation fluids

Temperature Limitations:
Can be used across a wide temperature range, no lower temperature limitation on performance. Has been effectively used up to BHT of 350 F.

Characteristics and notes

Surfactant RX 112 (Non Ionic fracturing surfactant) effectively lowers interfacial tension between stimulation fluids and hydrocarbons. It lowers the capillary pressure and allows for greater penetration in to the formation face, therefore promoting the recovery of stimulation fluids, connate fluids and hydrocarbons.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name : Surfactant Non Ionic fracturing RXSOL112
Part Number : RXSOL-81-2224-210

Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Branch : Kandla, Mumbai , Chennai, Vizag, Kolkata, UAE , OMAN and CANADA, Nairobi 

Phone +91 22 27815540 / 41 / 42
Fax +91 22 2761 2100 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
Website www.rxmarine.com
Name     of        Substance                                         Cas Number EC  No Wt.% Symbol
Poly(oxy-1,2-ethanediyl), alphahexyl-omega-hydroxy 500-077-5 31726-34-8 10-<20  Xi
Dicoco Dimethyl quaternary Ammonium chloride 263-087-6 61789-77-3 0.5-<1.0  Xn
Propan-2-ol 200-661-7 67-63-0 0.1-<0.25  Xn
Non   Hazardous  Compound                                      Proprietory   ----- 40 - 50%  ---
Signal Word                        Warning
Hazard Statements

H315 - Causes skin irritation
H319 - Causes serious eye irritation
H412 - Harmful to aquatic life with long lasting effects

Precautionary statements - prevention

P273 - Avoid release to the environment
P280 - Wear protective gloves and eye/face protection
P302 + P352 - IF ON SKIN: Wash with plenty of soap and water
P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to
do. Continue rinsing
P391 - Collect spillage
P501 - Dispose of contents/container in accordance with local, regional, national, and international regulations as applicable
P337 + P313 - If eye irritation persists: Get medical advice/attention
P264 - Wash face, hands and any exposed skin thoroughly after handling
P332 + P313 - If skin irritation occurs: Get medical advice/attention
P362 - Take off contaminated clothing and wash before reuse

Precautionary statements - response IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER or doctor/ physician. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a doctor/ physician. Wash contaminated clothing before reuse. Absorb spillage to prevent material damage.
Storage: Store locked up. Store in corrosive resistant stainless steel container with a resistant inner liner.
Disposal: Dispose of contents/ container to an approved waste disposal plant.

  

Eye Contact Hold eye open and rinse slowly and gently with water for 15-20 minutes. Remove contact lenses, if present, after the first five minutes, then continue rinsing eye. Get immediate medical attention.
Skin Contact Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. Get medical attention if irritation persists.
Inhalation:              If inhaled, remove from area to fresh air. Get medical attention if respiratory irritation develops or if breathing becomes difficult.
Ingestion: If swallowed, call a poison control center or doctor immediately. Do NOT induce vomiting. If conscious, drink plenty of water.
General Advice The severity of the symptoms described will vary dependant of the concentration and the length of exposure. If adverse symptoms develop, the casualty should be transferred to hospital as soon as possible.
Suitable extinguishing media Extinguish with carbon dioxide, dry chemical, foam or waterspray.
 
Protective  Equipment                       Use personal protective equipment.
Hazardous combustion products Thermal decomposition can lead to release of irritating gases and vapors Carbon oxides (COx), Nitrogen oxides (NOx).
Advice for firefighters As in any fire, wear self-contained breathing apparatus and full protective gear.
Specific extinguishing methods Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.Containers close to fire should be removed immediately or cooled with water. Hazchem code ADG

 

Personal precautions, protective equipment and emergency procedures

Ensure adequate ventilation. Keep people away from and upwind of spill/leak. Avoid inhalation, ingestion and contact with skin and eyes. Wear suitable personal protective equipment.Respiratory protective equipment.

Enviromental  Precaution  Do not allow contact with soil, surface or ground water.If the products get into drains, inform the relevant authorities immediately.
Methods and materials for
containment and cleaning up
Stop leak if safe to do so. Contain spillage, and then collect with non combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13). Flush away traces with water. For large spills, dike spilled material or otherwise contain material to ensure runoff does not reach a waterway.
Advice on safe handling Handle in accordance with good industrial hygiene and safety practice. Do not get in eyes, on skin or on clothing. Avoid spills and splashing during use.
Storage Technical measures/precautions Ensure adequate ventilation. Keep airborne concentrations below exposure limits.
Storage precautions Keep containers tightly closed in a dry, cool and well-ventilated place Avoid contact with:
Strong oxidizing agents Storage class Chemical storage.
Advice on general occupational hygiene Use good work and personal hygiene practices to avoid exposure. When using do not smoke, eat or drink. Wash hands before eating, drinking or smoking Remove contaminated clothing
Component Information

ChemicalName

Arabic

Australia

Egypt

Poly(oxy-1,2-ethanediyl), alphahexyl-omega-hydroxy-

Not determined

Not determined

Not determined

Dicocodimethyl quaternary ammonium chloride

Not determined

Not determined

Not determined

Propan-2-ol

500 ppmSTEL

1230 mg/m3STEL

400ppmTWA

983mg/m3TWA

500 ppm STEL 1230 mg/m3 STEL 400 ppm TWA 983 mg/m3 TWA

500 ppmSTEL

1230 mg/m3 STEL

400 ppm TWA

983 mg/m3 TWA

ChemicalName

India

Indonesian

Japan

Poly(oxy-1,2-ethanediyl), alphahexyl-omega-hydroxy-

Not determined

Not determined

Not determined

Dicocodimethylquaternary ammonium chloride

Not determined

Not determined

Not determined

Propan-2-ol

Not determined

400 ppm TWA

983 mg/m3 TWA

500 ppmSTEL

1230mg/m3STEL

200 ppm ACL

ChemicalName

Kazakhstan

Kuwait

NewZealand

Poly(oxy-1,2-ethanediyl), alphahexyl-omega-hydroxy-

Not determined

Not determined

Not determined

Dicocodimethylquaternary ammonium chloride

Notdetermined

Notdetermined

Notdetermined

Propan-2-ol

10 mg/m3 MAC

1225 mg/m3 STEL

500 ppm STEL

500 ppm STEL

1230 mg/m3 STEL

400 ppm TWA

983 mg/m3 TWA

ChemicalName

Malaysia

Philippines

Russia

Poly(oxy-1,2-ethanediyl), alphahexyl-omega-hydroxy-

Not determined

Not determined

Not determined

Dicocodimethylquaternary ammonium chloride

Not determined

Not determined

Not determined

Propan-2-ol

400 ppm TWA

983 mg/m3 TWA

400 ppm TWA

980 mg/m3 TWA

50 mg/m3 STEL

10 mg/m3 TWA

ChemicalName

Thailand

Vietnam

Turkey

Poly(oxy-1,2-ethanediyl), alphahexyl-omega-hydroxy-

Not determined

Not determined

Not determined

Dicocodimethylquaternary ammonium chloride

Not determined

Not determined

Not determined

Propan-2-ol

400 ppm TWA

Not determined

Not determined

Engineering Controls

Ensure adequate ventilation Mechanical ventilation or local exhaust ventilation is required.

Personal   Protection Eye protection : Wear eye protection/ face protection.
Hand protection : Wear the following personal protective equipment: Standard glove type. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough.
Skin protection : Personal protective equipment comprising: suitable protective gloves, safety goggles and protective clothing
Respiratory protection : When workers are facing concentrations above the exposure limit they must use appropriate certified respirators.
Exposure Conrol 

All chemical Personal Protective Equipment (PPE) should be selected based on an assessment of both the chemical hazard present and the risk of exposure to those hazards. The PPE recommendations below are based on an assessment of the chemical hazards associated with this product. Where this product is used in a mixture with other products or fluids, additional hazards may be created and as such further assessment of risk may be required. The risk of exposure and need of respiratory protection will vary from workplace to workplace and should be assessed by the user in each situation.

Hygiene measures Handle in accordance with good industrial hygiene and safety practice. Remove and wash contaminated clothing before re-use. Wash face, hands and any exposed skin thoroughly after handling. Provide suitable facilities for quick drenching or flushing of the eyes and body in case of contact or splash hazard.

                                       

 Gloves                   Suit            

              

  

Form         Liquid
Apperance Aqueous solution, Clear Yellow
Odour Alcohol
Odor threshold Not applicable
Flash Point  > 93.3 °C / > 199.4 °F PMCC
Boiling Point ~ 100 °C / 212 °F
Freezing Point 5 °C / 41 °F
pH  9 -11
Evaporation rate No information available
Flammability (solid, gas) No data available
Upper explosion limit No data available
Lower explosion limit No data available
Explosive properties No data available
Vapor pressure No data available
Vapor density No information available
Specific gravity 0.99 - 1.03 g/cm3 @ 20 °C
Relative density ~ 1.0 @ 20°C.
Water solubility Soluble
Solubility in other solvents No data available
Partition coefficient: octanol No data available
Autoignition temperature No data available
Thermal decomposition No data available
Viscosity, kinematic No data available
Explosive properties No data available
Oxidizing properties No data available
Dynamic viscosity 5-50 mPa s @ 16 °C
VOC (%)  < 1
Pour point No information available
Recativity                                             No specific reactivity hazards associated with this product.
Stability Stable under normal  conditions and recommended use.
Possibility of hazardous reactions No dangerous reaction known under conditions of normal use.
Incompatible materials Avoid to contact with oxidizing agents.
Hazardous Decomposition

Thermal decomposition can lead to release of irritating gases and vapors Carbon oxides (COx), Nitrogen oxides (NOx).

Condition to Avoid None Known
Polymerization Hazardous polymerization does not occur.

Acute toxicity

 
Route of Exposure Inhalation, Eye contact, Skin contact
Eyes                                    

Causes serious eye irritation.

Skin Causes skin irritation.
Ingestion  Ingestion may cause gastrointestinal irritation, nausea, vomiting and diarrhea.
Inhalation Inhalation of vapors in high concentration may cause irritation of respiratory system.

Unknown acute toxicity 

Not applicable.
Toxicology data for the components

ChemicalName

LD50Oral

LD50Dermal

LC50Inhalation

Poly(oxy-1,2-ethanediyl), alphahexyl-omega-hydroxy-

LD50:1250mg/kg,rat,(based ondatafromsimilarsubstance)

LD50: > 2000 mg/kg, rat, (basedondatafromsimilar component)

Nodataavailable

Dicocodimethylquaternaryammoniumchloride

=960mg/kg(Rat)

LD50>2930mg/kg,rabbit

Nodataavailable

Propan-2-ol

=1870mg/kg(Rat)

=4059mg/kg(Rabbit)

=72600mg/m3(Rat)4h

Sensitization This product does not contain any components suspected to be sensitizing.
Mutagenic effects  This product does not contain any known or suspected mutagens.
Carcinogenicity This product does not contain any known or suspected carcinogens
Reproductive toxicity This product does not contain any known or suspected reproductive hazards.
Specific target organ toxicity -Single exposure Not classified
Specific target organ toxicity -Repeated exposure Not classified
Aspiration hazard Not applicable.
Other information 

Key literature references and sources for data. See Section 16 for more information.

 

Toxicity

Harmful to aquatic life with long lasting effects

Toxicity to alge See component information below.
Toxicity to daphnia  and others See component information below.
Toxicity to Fish                     See component information below.
Toxicology data for the components  

ChemicalName

Toxicitytofish

Toxicitytoalgae

Toxicitytodaphniaandother aquatic invertebrates

Poly(oxy-1,2-ethanediyl), alphahexyl-omega-hydroxy-

LC5096h,Brachydaniorerio

(zebrafish):>100mg/l(testbased on similar component)

EC50,72h:>100mg/kg(basedon similar substance)

EC50,48h,Daphniamagna(Water

flea):>100mg/l(basedonsimilar product)

Dicocodimethylquaternary

ammoniumchloride

Noinformationavailable

Noinformationavailable

EC50,48h,Daphnia:0.01mg/l

Propan-2-ol

> 1400000 µg/L LC50 Lepomis macrochirus 96 h = 11130 mg/L LC50Pimephalespromelas96h=

9640mg/LLC50Pimephales promelas 96 h

>1000mg/LEC50Desmodesmus subspicatus 96 h > 1000 mg/L EC50 Desmodesmus subspicatus 72 h

=13299mg/LEC50Daphnia magna 48 h

Persistence and degradability

Chemical Name

Persistence and degradability

Poly(oxy-1,2-ethanediyl), alphahexyl-omega-hydroxy-

Readily biodegradable

Dicocodimethylquaternaryammonium chloride

No information available

Propan-2-ol

Readily biodegradable

Bioaccumulative potential

Chemical Name

Bioaccumulation

Poly(oxy-1,2-ethanediyl), alphahexyl-omega-hydroxy-

Not likely to bioaccumulate

Dicocodimethylquaternaryammonium chloride

No information available

Propan-2-ol

No bioaccumulation potential

Mobility

Chemical Name

Mobility

Poly(oxy-1,2-ethanediyl), alphahexyl-omega-hydroxy-

Miscible in water

Dicocodimethylquaternaryammonium chloride

Soluble in water                     

Propan-2-ol

Soluble in water

Results of PBT and vPvB assessment

Not classified as PBT/vPvB by current EU criteria.

 

Remarks Please consider the relevant national or regional provisions. Waste shall be separated into the categories that can be handled separately by the local or national waste management facilities.
Waste Disposal The product should not be allowed to enter drains, water courses or the soil. Where possible recycling is preferred to disposal or incineration. If recycling is not practicable, dispose of in compliance with local regulations. Dispose of wastes in an approved waste disposal facility
UN        Number                                          Not Regulated
Proper shipping name The product is not covered by international regulation on the transport of dangerous goods
Transport hazard class(es)
ADR/RID Hazard class/division  Not regulated
Subsidiary risk IMDG Hazard class/division  Not regulated
Subsidiary risk IATA  Hazard class/division  Not regulated
Packing group
Packing group Not regulated
Environmental hazards
Environmental hazards No
Marine pollutant No
ADR/RID
Hazchem code ADG 3Z 
Tunnel Category Not Reguted
IMDG
EmS Code Not Reguted
IATA
Packing Instruction (Cargo) Not Reguted
Maximum quantity Not Reguted
Packing Instruction (Passenger) Not Reguted
Maximum quantity Not Reguted 

 

Regulations

Safety, health and environmental regulations/legislation specific for the substance or mixture

The Globally Harmonized System of Classification and Labeling of Chemicals (GHS)

National Code of Practice for the Preparation of Material Safety Data Sheets 2nd Edition [NOHSC: 2011 (2003)].

National Occupational Health and Safety Commission’s Approved Criteria for Classifying Hazardous Substances
[NOHSC:1008 (2004) 3rd Edition].

National Occupational Health and Safety Commission’s Exposure Standards for Atmospheric Contaminants in the
occupational Environment [NOHSC:1003 (1995)]. Safe Work Australia.

Standard for the Uniform Scheduling of Drugs and Poisons (SUSDP).

ADG Code – Australian Dangerous Goods Code
 

International inventories

USA (TSCA)                       Complies
Canada (DSL)                     Complies
Philippines (PICCS)            Does not comply
Japan (ENCS)                     Complies
China (IECSC)                    Complies
Australia (AICS)                  Complies
Korean (KECL)                   Complies
New Zealand (NZIoC)         Complies

Further information FOR INDUSTRIAL USE.
 
Other Information  

The information above is believed to be accurate and represents the  best information   currently    available  to us.  However,   we   make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and  we assume  no liability resulting from its use. Users should make  their  own  investigations  to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International  has been advised of the possibility of such damages.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Surfactant Non Ionic fracturing RXSOL112 manufacturer and supplier in India, UAE GULF, Middle East, Kenya Nairobi, Oman Muscat. RXSOL Surfactant Non Ionic fracturing RXSOL112 stockist and supplier in Fujairah, Ajman, Dubai, Sharjah, Abudhabi, Barka Sohar, Nairobi Kenya Africa, Canada

Our stock points and branches