FERRIC SULPHATE SOLUTION

Size:

Color:

Product Short Description: Ferric Sulphate Solution 50 percent 250 Kg Liquid Pack
Product Technical Specification:
RXSOL is a leading supplier of Ferric Sulfate Fe2(SO4)3, an iron based acidic compound used for industrial wastewater pretreatment. RXSOL recommends Ferric Sulfate for pH adjustment, coagulation and dissolved heavy metal precipitation. Ferric Sulfate starts out as a dissolved solid, but falls out of solution and becomes a suspended solid at multiple pH levels for easy filtration.
Remarks:

Handling :

The handling of any chemical requires care. Anyone responsible for using or handling Ferric Sulfate should familiarize themselves with the full safety precautions outlined in our Material Safety Data Sheet.

Storage

Storage tanks and piping should be constructed of suitable material such as stainless steel, fiberglass, or cross-linked polyethylene. With this chemical it is recommended to clean the storage tank every 1-2 years.

Images: Alt



Corrosion Scale Inhibitor Phosphate Based

Size:

Color:

Product Short Description: Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.
Product Technical Specification:
 
Property Value
Appearance Clear to slightly hazy amber liquid
Odor Mild characteristic
pH (as supplied) Alkaline
Specific Gravity @ 25°C 1.10 – 1.20
Solubility Fully water soluble
Freeze Point Below 0°C
Shelf Life 12 months (sealed container)
Remarks:
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System  product does not require additional acid treatment. 
ADVANTAGES of RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System
Clean Surfaces  - Maximum heat transfer  -
Its regular doses increases Higher efficiency
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System  - Reduced Maintenance down time  - Increased production
Non Toxic  - Easy and Safe in use 
Images: Alt



Biocide Antimicrobial for Cooling Water

Size:

Color:

Product Short Description: Highly effective biocide used in Cooling Water Systems which eradicates microbes, bacteria etc easily
Product Technical Specification:

Biocide Antimicrobial for Cooling Water RXSOL-43-4009-250  is an organic chlorine releasing microbiocide which will effectively control the growth of algal slimes on cooling Water distribution decks, fill, and basins.
This product is recommended for use in industrial process cooling towers, air conditioning cooling systems, and evaporative condensers. It is particularly recommended for use in systems where algae growth is especially difficult to control.

Remarks:

How to control Algae growth in cooling towers, air conditioning cooling systems, and evaporative condensers?

RXSOL-40-4009-210  MICRO BIOCIDE Cooling Water RXSOL  is an organic chlorine releasing microbiocide which will effectively control the growth of algal slimes on cooling Water distribution decks, fill, and basins.

This product is recommended for use in industrial process cooling towers, air conditioning cooling systems, and evaporative condensers. It is particularly recommended for use in systems where algae growth is especially difficult to control.

Images: Alt



Bio Dispersant Cooling Water Treatment Fouling Control

Size:

Color:

Product Short Description: Bio-Dispersant effectively cleans and disperse heavily fouled Cooling Water Systems
Product Technical Specification:
Product Properties

Fprm:

Liquid

Colour:

Yellow or Brown

Odour:

Slight

pH:

6.5

Relative density:

1.05

Solubility in water:

Complete

Boiling point:

~100 0C

Flash point:

>100oC

*Full details of the product properties are available in the Safety Data Sheet.

Remarks:

High performance cooling water bio-dispersant

RXSOL-40-4093-210 is a high specification product developed to improve the performance of cooling water systems where fouling by microbiological slimes is reducing overall system efficiency, by removing and dispersing the unwanted deposits.

RXSOL-40-4093-210 is extremely effective at controlling oil based fouling and is the ideal solution for use in both re-circulating and once-through cooling water systems.

Images: Alt



Potassium Diethyldithiocarbamate Cooling Water Treatment

Size:

Color:

Product Short Description: Very effective controler of BACTERIA in water system.
Product Technical Specification:
Remarks:
Images: Alt



Nonylphenyl Polyethylene Glycol Ether Cooling Water Treatment

Size:

Color:

Product Short Description: Ethoxylated nonionic surfactant mixtures 9.5 Moles fully reacted and widely used in Pharmaceutical Industry, Cooling Water Treatment, Chemical Industry, Medical Drugs, detergent etc.
Product Technical Specification:

 

Physical Appearance Clear Colourless Viscous liquid without sediments
Colour, HU, max. 50
Purity (% by mass) min. 99.0
Dinonyl Phenol (% by mass) max. 1.0
Phenol (% by mass) max. 0.1
Water content (% by mass) max. 0.05
Specific Gravity 27/27 Deg.C 0.945
Hydroxyl value, mg KOH/gm 248
Distillation range 95% to distill , Deg.C 288 - 310
 
Remarks:
Images: Alt



Corrosion Inhibitor Zinc Based

Size:

Color:

Product Short Description: Corrosion Inhibitor with Zinc salts and Polyphosphates
Product Technical Specification:
PHYSICAL CHARACTERICS 
Appearance   : Clear Liquid - Also available in PINK colour
Specific Gravity  : 1.10 to 1.20
Flash Point  : Non Flammable 
Freezing Point  : 0 Degrees Cent. 
Remarks:
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System  product does not require additional acid treatment. 
ADVANTAGES of RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System
Clean Surfaces  - Maximum heat transfer  -
Its regular doses increases Higher efficiency
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System  - Reduced Maintenance down time  - Increased production
Non Toxic  - Easy and Safe in use 
Images: Alt



Nitrite Borax RoccorRX NB Liq

Size:

Color:

Product Short Description: Usefull for use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Protects all metals including cast iron, mild steels and c
Product Technical Specification:

Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate. hours> 4. Re check the readings. and record. 5 track these readings
for a period of time.

If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.

Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-Algaecide

Remarks:
Images: Alt



Alkaline Corrosion Inhibitor for Boiler

Size:

Color:

Product Short Description: Caustic based alkaline corrosion inhibitor for Boiler treatment
Product Technical Specification:
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



OxyShield Plus Boiler Oxygen Scavenger

Size:

Color:

Product Short Description: Scavenges oxygen and passivates iron and copper surfaces, rendering them more resistant to corrosion
Product Technical Specification:
Appearance Clear Liquid
Odor Amine like
pH 10-11
Remarks:

#OxygenScavengerforBoiler

#OxygenScavengermanufacturer

#OxygenScavengersupplier

#AminebasedOxygenScavenger

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Multi Functional Boiler Treatment

Size:

Color:

Product Short Description: Highly effective multi-functional liquid reagent for the treatment of steam production systems and heating systems operating on softened water.
Product Technical Specification:

Boiler Water Treatment products

CHARACTERISTIC :

  • Convenient liquid treatment, which provides the basic alkalinity on which successful water treatment depends.
  • Provides optimum conditions for hardness control to function.
  • Neutralizes acid conditions.
  • Will assist in keeping silica in suspension.
  • Simple test to determine level of treatment.
  • Can be used in boilers of all pressures.
  • Can be used as a neutralizer after acid cleaning operations
  • Suitable for use with all auxiliary boilers; waste heat units; economizers, package boilers, smoke and water tube boilers.
  • Dispersant action suspends sludge and sediment particles for efficient blow down.
  • Oxygen scavenging for optimum protection.
  • Protects boiler, steam lines, condensate lines and feed water lines from corrosion.
  • Fast action due to catalyst.
  • Simple test to determine level of treatment.
Remarks:

RXSOL-42-5001-025 Boiler Water treatment specialized is a well - balanced blend for boiler water treatment products, Resulting Multi Functional Boiler Treatment including scale and corrosion control by one shot operation. A one-step treatment to control the formation of rust and scale in low pressure and auxillary boilers with working pressure up to 20 bars.

The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. 


Basic Boiler System Schematic

Below is a summary of problems associated with the common impurities in water and solutions to each problem.

List Of Problems Caused By Impurities In Water

Impurity (Chemical Formula)

Problems

Common Chemical Treatment Methods

Alkalinity (HCO3-, CO32- and CaCO3)

Carryover of feedwater into steam, produce COin steam leading to formation of carbonic acid (acid attack)

Neutralizing amines, filming amines, combination of both, and lime-soda.

Hardness (calcium and magnesium salts, CaCO3)

Primary source of scale in heat exchange equipment

Lime softening, phosphate, chelates and polymers

Iron (Fe3+ and Fe2+)

Causes boiler and water line deposits

Phosphate, chelates and polymers

Oxygen (O2)

Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)

Oxygen scavengers, filming amines and deaeration

pH

Corrosion occurs when pH drops below 8.5

pH can be lowered by addition of acids and increased by addition of alkalies

Hydrogen Sulfide (H2S)

Corrosion

Chlorination

Silica (SiO2)

Scale in boilers and cooling water systems

Lime softening

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



ANTISCALANT 9209 Seawater Distillation

Size:

Color:

Product Short Description: Antiscalant for Water Distillation Units , specially designed to control the development of scale in seawater distillation plants.
Product Technical Specification:

 

Appearance Clear, Yellowish Amber Liquid
Flash point Non-flammable
Solubility in water Soluble in all proportions
Freezing Point -15 Degree

SAFETY INFORMATION:

Gloves and goggles should be worn as a precaution when handling the concentrated solution. (See Material Safety Data Sheets for further information).

Remarks:

SAFETY INFORMATION:

Gloves and goggles should be worn as a precaution when handling the concentrated solution. (See Material Safety Data Sheets for further information).
Antiscalant 9209 RX  is compatible with carbon steel and other commonly used materials of construction. Observe all safety precautions shown in the material safety data sheet, available on request.

Images: Alt
stock-clearance.png