RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,087 products across 101 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Electrical Cleaner

Degreaser Electrical Non Flame

Electrical Non Flammable safe degreaser for Electric Motor and Equipment Cleaning
Part number
RXSOL-10-1738-025
Brand
RXSOL
Degreaser Electrical Non Flame

Overview

Safety Electrical Cleaner & Degreaser is a non-flammable, non-conductive fast-evaporating cleaner penetrates instantly to remove dirt, oil, grease and wax. This is safe industrial grade cleaner meant for electronic equipments, generators, motor-power tools, electrical parts etc.

Being non-flammable, it can be safely used to clean motors and generators. Electrical Cleaner & Degreaser effectively removes the oil, grease, carbon without the need of rinsing with water.

It increases the life of electrical components by removing foreign materials that can cause costly downtime.

Technical specifications

  • Cleans Effectively 
  • Cuts Down Costly Hours Of Downtime
  • Extends Equipment Life Span
  • Leaves No Residue
  • Non-Oily
  • Non-Flammable
  • Reduce Fire Hazards

Applications

Safety Electrical Cleaner & Degreaser is used for industrial machineries, metal surfaces and other electrical parts. It is widely used in power stations, refineries, vessels, hotels, aviation industries, oil and gas industries, manufacturing plant etc. to clean Electric motors, generators, air tools, brakes, clutches, chains, sprockets, wire rope, dies, molds, relays, radar equipment, material handling equipment, air conditioners.

Dosage and directions

For Spray Method :::

  1. Electrical Cleaner & Degreaser generously on surfaces that require cleaning. 
  2. Brush or agitate if necessary 
  3. Leave to dry.
  4. For stubborn grease, manual agitation with a brush or cloth may be required.

For DIP METHOD :::

  1. Shake well before use.
  2. Pour the product into a metal container
  3. Soak parts to be cleaned into Safety Electrical Cleaner & Degreaser for about 5 to 15 minutes
  4. Brush or agitate if necessary. 
  5. For parts with stubborn grime or sludge, soak for a longer period of time and cover with a tight lid to prevent evaporation loss.

Characteristics and notes

Note: After cleaning, apply new grease, oil or coating before using the motor.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet


Product Name Degreaser for safe Electrical Non Flammable
Part Number RXSOL-10-1738-025

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.

VASHI ,NEW BOMBAY 400703 INDIA

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
Website www.rxmarine.com
Chemical Name Percent CAS NO. OSHA Exposure Limits
Ethyl Hydroxy Propionate >96% 97-64-3  None

 None

Molecular Formula: CH3-CH(OH)-COO-CH2CH3

Acute Health Effects:
Eyes:
Risk of damage
Skin Contact: Not an irritant
Inhalation: Possible narcotic effects at excessive exposure.
Chronic Health Effects: Oral Allowed as food additive by FDA and FAO/WHO; not listed as a carcinogen
Routes of Entry: Most common – skin and inhalation
Medical Conditions Aggravated by Exposure: Mist may cause eye/respiratory irritation with coughing

Eye : Immediately flush with water for at least 15 minutes. See a medical doctor immediately.
Skin : Rinse with water
Inhalation : Remove to fresh air. If discomfort occurs and persists, obtain medical attention.
Ingestion : Induce vomiting. See a doctor immediately.

First Aid: In case of contact, immediately flush eyes with water for at least 15 minutes. If irritation persists, obtain medical attention. Flush skin with water.

Extinguishing Media: Water, water fog, carbon dioxide (CO2), dry chemical
Special Procedures: Wear Approved respirator
Degree of Fire and Moderate
Explosion Hazard: Hazardous DecomPosition Procedures: None. Decomposes to water and CO2 when completely combusted.

Procedure for Release or Spill : Cover with large quantity of absorbent material (e.g. kitty litter) and collect in drums fordisposal. Clean contaminated area with water and discharge to sewer.

Handling : Keep container tightly closed. Store in a cool, dry, well-ventilated, liquid storage area.
Ventilation: Use adequate general or local exhaust ventilation to keep vapor and mist levels as low as possible.
Storage : Store in a cool, dry area away from acids.

Recommended Personal Protective Equipment:

Respiratory : None required where adequate ventilation conditions exist.
Ventilation : Local Exhaust recommended
Eye Protection : Use chemical goggles
Gloves : Use impervious gloves to prevent skin contact.
Clothing & Equip. : Aprons recommended. If clothing becomes contaminated,remove and launder before reuse.
Foot Protection : Industrial safety shoes
Engineering Controls : None identified
Work Practices : Do not smoke in areas of storage or use
Other Protection : Non Identified
Precaution : Avoid contact with skin and eyes.

Control Measures: Minimize eye and skin contact by using appropriate protective equipment. Use local or general room ventilation to control vapors or mist that may be generated into the work environment. 

                                

        Gloves                       Suit                          

Form  : Liquid
Physical state  : Liquid
Color  : Clear
Odor  : Slight
Flash point  : 139 °F
Melting Point  : Not Applicable
Specific Gravity  : 1.030-1.038
Oxidizing properties  : No data available
Vapor Pressure (mmHg)  : 1.7
Vapor Density (air=1)  : 4.07
Flammable limits @ 212o F  : Lel – 1.6% Uel – 10.6%
Odor Threshold  : 0.89 mg/m3 (0.18 ppm)
Bulk Density (G/ML)  :  Not applicable
Partition coefficient  : n-octanol/water – not applicable
Autoignition Temperature  : 752o F
Evaporation rate (butyl acetate=1)  : 0.22
Bulk Density (G/ML)  : Not applicable
Water solubility  : Soluble
Explosive Properties  : No data available
Viscosity, kinematic  : No data available
Relative vapor density  : No data available
Evaporation rate  : No data available
Stability : Stable
Hazardous Polymerization : None known
Conditions to Avoid : None known
Materials to Avoid : strong oxidizing agents
Contaminants that Contribute Instability: :

None

Incompatibility : None known
Hazardous Decomposition Products : None
Sensitivity to Mech. Impact : None
Sensitivity to Static Discharge : None


Eye Contact : Severe irritant (rabbit)
Skin Contact : LD 50 (rats/24 hrs.) >2000mg/kg
Skin Absorption : No data available
Inhalation : LD 50 (rat/4 hrs.) >5400 mg/m3
Ingestion : LD 50 = 4090 MG/KG (rat) (RTECS 1985-86)
Acute Effects : May cause severe irritation of the eyes
Chronic Effects : None identified

Environmental Data: 100% biodegradable
Environmental Effects: No adverse effects known or suspected. Not listed toxic chemical under SARA Title 111.302, 304 or 313

Waste Disposal Method: Take up with sand or other non-combustible absorbent material and place into container for later disposal. Flush area with water. Dispose in accordance with all applicable Federal, State and local environmental regulations.

DOT Proper Shipping Name : Ethyl Hydroxy Propionate
IATA : Not applicable
IMDG : Class 3.3
DOT Classification : Combustible Liquid N.O.S.
DOT Labels : Flammable Liquid, 3
DOT Marking : Not applicable
DOT Placard Bulk : Flammable liquid 1192
DOT Placard Drums : No placard required under 110 gal
Hazardous Substance/RQ : Not applicable
Precautions To Be Taken in Transport : None needed
Other Shipping Information : None

Proper Shipping Name: Ethyl Hydroxy Propionate
Hazard Class: 3.3
Packaging Group: III
Reportable Quantity: None
Label Required (drums): None
Placard Required (Bulk): Placard flammable liquid 1192
Maximum Quantity – Aircraft: No limit
Stowage on vessels: Above or Below Deck
OSHA Exposure Limits Substance(s): Ethyl Hydroxy Propionate

OSHA PEL-TWA : Not applicable
STEL : Not applicable
Ceiling : Not applicable
Skin Designation : Not applicable
AGGIH TLV-TWA : Not applicable
Target Organ Effects : Eye
Carcinogenic Potential : None
Regulated by OSHA : No
Listed on NTP Report : No
IARC Group 1, 2A, 2D : No
SARA Title III Sec 302-303 (40 CFR 355) Sub. : Not applicable
RQ : Not applicable
Planning Threshold : Not applicable

Canada Ingredient Disclosure List Substance(s): Ethyl Lactate

Controlled Product   Not applicable
Hazard Symbols   Not applicable
Class and Division   Not applicable
Product Identification No   Not applicable
Domestic Substance List   Not applicable
CEPA Priority List   Not applicable
Carcinogenicity   Not listed in other OSHA, ACGIH, NTP, or IARC
ACGIH Appendix A   Not listed
A1 – Confirmed Human   Not listed
A! – Suspected Human   Not listed
IARC Group 1 or 2   No
Label Language (US/Canada) Health   Not Applicable

HMIS LABEL

HEALTH: 1
FLAMMABILITY: 2
REACTIVITY: 0
PERSONAL PROTECTION: B

The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall Rx Marine International be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International has been advised of the possibility of such damages.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Degreaser Electrical Non Flame manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Degreaser Electrical Non Flame at a competitive price from us. We have ready stock of Degreaser Electrical Non Flame in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches