Electrosol Quick Dry
- Part number
- RXSOL-16-1009-025
- Category
- Electrical Cleaner
- Brand
- RXSOL
Overview
Electrical Parts Cleaner CRC Quick Dry Electronic Cleaner. Also used as specialist Electrical Contact Cleaner and Electric Motor Contact Cleaner. its ffective degreasing action with fast evaporation and no residue effect makes no1 choice among our end user customer. The non-flammable property is designed for energized equipment ans use on energized electric motors, fusible disconnects, switchgears, transformers, circuits, insulators, relays, and switches.
Its other brand name is CRC Lectra-Motive Electric Parts Cleaner, Electrical Parts Cleaner - CRC, CR QD Electronic Cleaner,
RXSOL-16-1009-025 is a well balanced blend of non - chlorinated degresol ( having super digressing power ) with surfactants. Its rapid evaporation rate enables it to be used for cleaning and decreasing of electrical equipment,motor winding etc.
It is economical to use and can be applied on large motors, generators, and electrical apparatus, as well as smaller equipment.
It is highly effective for the cleaning of electric motors and switch gear on printing presses, meta components. RXSOL-16-1009-025 greatly reduces the toxic dangers of hazardous solvents like trichloroethylene and carbon tetrachloride, solvents that are banned by many leading industries.
A well-balanced blend of advanced degresol solvents combined with high-efficiency surfactants, specially engineered for rapid and powerful degreasing of electrical and mechanical components.
Designed to tackle heavy grease, oil, carbon, and grime deposits, it ensures instant penetration and quick drying, leaving no residue behind. Its optimized evaporation rate allows for fast turnaround and minimizes downtime—ideal for use on electrical motors, generators, switchgear, control panels, and other precision components.
Technical specifications
63°C (Closed Cup) |||
| Stability | Very stable understandard, normal conditions |
|---|
May swell |||
| Note | After use the product must always be well sealed in the drum |
|---|
Packaging |||
| Order No | ||| |
|---|
Applications
- High dissolving and penetration action.
- Excellent degreasing and emulsification power .
- Safe on applied electrical insulation.
- Non-corrosive .It is safe to use on painted or varnished metal surfaces.
- Without chlorinated solvents.
- To be used as an alternative to conventional electric cleaners
XRC, Careclean ECS Quick Dry, Electroclean A Quick Dry, Electrosolve -E, arma clean, Electrical contact cleaner, Fast Evaporating Degreaser, IMPA: 55 33 24, Orion 77, 651 604389, Eazy Electric Fast Dry, Florin-2000, UKLEEN L-65
Dosage and directions
It must be applied concentrated .
RXSOL-16-1009-025 is also fast evaporating leaving no residue. RXSOL-16-1009-025 is ideal for use on electric motors, plant machinery, elevator shafts and motors, generators, condensers, coils, etc.
RXSOL-16-1009-025 is safe to use on metal or rubber surfaces. reduces fire hazards caused by defective electric motors: RXSOL-16-1009-025 rapidly breaks down oils,and waxes. RXSOL-1009 can also be used to remove oil and stains from material.
(TEST A SMALL AREA FIRST )
A few minutes soaking is usually sufficient to loosen and disperse most oily deposits. For severely soiled parts or windings, RXSOL-16-1009-025 cleaner may be allowed to soak into the deposits for up to two hours.
Characteristics and notes
CLASSIFICATION : * ELECTROSOL QD (quick dry ) *ELECTROSOL NF (Non-flammable ) *ELECTROSOL PLUS APPLICATION : For cleaning of electrical parts .
Electrical Contact Cleaner manufacturers, Electrical Contact Cleaner suppliers, Electrical Contact Cleaner producers, Electrical Contact Cleaner exporters, Electrical Contact Cleaner production unit at mumbai, kandla, Visakhapatnam, tuticorin, chennai, ennore, surat, kolkata, haldia, dubai, fujairah.
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | RXSOL-16-1009-025 |
| Product Type | ELECTROSOL QUICK DRY |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Kolkata, Chennai, Vizag, Fujairah, Muscat, Nairobi
| Phone | +91 22 65113333 / 5555 / 9999 / 27611360 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com |
|
Chemica Name |
Concentration |
CAS Number |
EC Number |
R Phrases* |
Symbols |
| Rock Oil |
60-100% |
64742-48-9 |
265-150-3 |
65, 66 |
Xn |
|
1,1,1 Trichloroethane |
20-40% |
71-55-6 |
|||
| 1,4 Dioxane | 40-60% | 123-91-1 | |||
| Proprietary Inhibitor | 5-10% |
*See Section 16
|
Odour |
Smells of hydrocarbon. |
|
Appearance |
Liquid, colourless, insoluble in water. |
|
Contactwith eyes |
Causes irritation. |
|
Contact with skin |
Prolonged skin contact will result in defatting of the skin, leading to irritation, and in some cases, dermatitis. |
|
Inhalation |
Vapours may cause drowsiness and dizziness (R67), In cases of severe exposure, anaesthesia may develop, In cases of severe exposure, chronic pneumonitis may develop. |
|
Ingestion |
The ingestion of significant quantities may cause nausea/vomiting, Harmful: may cause lung damage if swallowed (R65). |
|
General |
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45). |
|
Contact with skin |
Remove contaminated clothing Wash affected area with plenty of soap and water Contaminated clothing should be laundered before reuse Seek medical attention if irritation persists. |
|
Contact with eyes |
If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes Irrigate eyes thoroughly whilst lifting eyelids Seek medical attention if irritation persists. |
|
Ingestion |
Do not induce vomiting because of risk of aspiration into the lungs. If aspiration is suspected obtain immediate medical attention If vomiting occurs turn patient on side Give water or milk to drink Obtain immediate medical attention. |
|
Inhalation |
Remove patient to fresh air Keep warm and at rest, in a half upright position. Loosen clothing Seek medical attention if ill effects occur. |
|
General |
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45). |
- Auto-ignition point >200 deg C at 760 mm Hg.
- Lower flammability limit 0.6%(in air), Upper flammability limit 7%(in air), Flash point 63 deg C (CC).
- Decomposition products may include carbon oxides.
- In case of fire use water spray or fog, alcohol resistant foam, dry chemical or carbon dioxide (S43).
- Vapours are heavier than air and may travel considerable distances to a source of ignition and flashback.
- Keep container(s) exposed to fire cool, by spraying with water.
|
Personal Precautions |
Wear protective clothing as per section 8. |
|
Environmental Precautions |
Do not allow to enter public sewers and watercourses. |
|
Immediate Actions |
Use appropriate containment to avoid environmental contamination (S57). |
|
Clean Up Actions |
Absorb spillage in inert material and shovel up. Ventilate the area and wash spill site after material pick-up is complete |
|
Special Precautions |
Wear protective clothing as per section 8. Vapours are heavier than air and may travel considerable distances to a source of ignition and flashback Wear suitable respiratory protection. |
|
Handling |
Wear protective clothing as per section 8 During fumigation/spraying wear suitable respiratory equipment (S42) Avoid contact with skin and eyes (S24/25) Eyewash bottles should be available Keep away from sources of ignition - No Smoking (S16) |
|
Storage |
Keep container tightly closed, in a cool, well ventilated place (S3/7/9).Keep away from open flames, hot surfaces and sources of ignition. |
|
Exposure Limits |
TLV (TWA) 275 mg/m3 (White spirit (de-aromatized)) |
|
Exposure controls |
No special ventilation is required unless the product is used in a spray form The undiluted product must not be used in a confined space without good ventilation |
|
Occupational exposure controls |
Wear suitable protective clothing, including eye/face protection and gloves (neoprene or nitrile are recommended) Respiratory protection may be required under exceptional circumstances when excessive air contamination exists. We arapproved respirator if exposure likely to exceed MEL/OES |
Respirator Gloves Goggles Suit
|
Odour |
Smells of hydrocarbon |
|
Appearance |
Liquid, colourless, insoluble in water |
|
pH |
not applicable |
|
Boiling point |
190 °C to 203 °C at 760 mm /Hg |
|
Vapour pressure |
40 Pa at 20 deg C |
|
Vapour density |
(air = 1) 5.4 |
|
Freezing point |
unknown |
|
Insoluble in water |
|
|
Specific gravity (water=1) |
0.79 |
|
Lower flammability limit |
0.6%(in air) |
|
Upper flammability limit |
7%(in air) |
|
Flash point |
63 deg C (CC) |
|
Auto-ignition point > |
200 deg C at 760 mm Hg |
|
Log Pow |
3.5 - 4.7 |
|
Viscosity |
1.59 cST @ 25 deg C |
- This article is considered stable under normal conditions.
- Avoid overheating, Keep away from naked flames, incandescent or hot surfaces.
|
Toxicological information |
LD50 (oral,rat) >2000 mg/kg.LD50 (dermal) : >2000 mg/kg.LC50 (inhalation) : >5 mg/l/4h. |
|
Inhalation |
Inhalation of solvent vapours may give rise to nausea, headaches and dizziness. |
|
Contact with skin |
Prolonged skin contact will result in defatting of the skin, leading to irritation, and in some cases, dermatitis. |
|
Contact with eyes |
In cases of severe exposure, irritation may develop. |
|
Ingestion |
May cause gastro-intestinal disturbances.Aspiration hazard Harmful: may cause lung damage if swallowed (R65). |
|
Carcinogenicity |
No evidence of carcinogenic effects. |
|
Ecotoxicity |
Low toxicity to fish.LC50 (rainbow trout) >1000 mg/l (96 hr).IC50 (algae) >100 mg/l (72 hr). |
|
Mobility |
Insoluble in water. |
|
Persistence and Biodegradability |
Biodegradability 67 % (OECD 301F). |
|
Bioaccumulation Potential |
Low bioaccumulation potential. |
|
Adverse Effects |
No environmental problems are expected when the product is used / handled correctly.In its intended use, the product will not be released into the environment. |
|
Classification |
EU Waste class: 07.01. |
|
Disposal considerations |
Do not discharge into drains or the environment, dispose to an authorised waste collection point Disposal should be in accordance with local, state or national legislation. |
- Not classified as hazardous for transport
|
Risk Phrases |
Harmful: may cause lung damage if swallowed (R65).Repeated exposure may cause skin dryness or cracking (R66) |
|
Safety Phrases |
Do not breathe vapour/fumes(S23) Avoid contact with skin (S24) Wear suitable gloves and eye/face protection (S37/39) If swallowed, do not induce vomiting: seek medical advice immediately and show this container or label (S62). |
Text of R and S phrase codes used in this safety data sheet:- R65: Harmful: may cause lung damage ifswallowed; R66: Repeated exposure may cause skin dryness or cracking.The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents.The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties. The data given here only applies when product used for proper application(s).The product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet Do not use for other.application(s) without seeking advice from manufacturer.
This Safety Data Sheet is provided in compliance with The Dangerous Substances Directive
This Safety Data Sheet is provided in compliance with The Dangerous Preparations Directive
This Safety Data Sheet is provided in compliance with The Safety Data Sheets Directive
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.
Availability
Electrosol Quick Dry Electrical contact cleaner manufacturer and supplier in India UAE OMAN. Electro Clean supplier in Mumbai, Gandhidham Kandla, Chennai Ennore, Kolkata Haldia, Visakhapatnam, Manglore, GOa, Fujairah, Sharjah, Ajman, Abudhabi, Muscat Barka Oman